Full-size digital storage phosphor chest radiography: effect of 4K versus 2K matrix size on observer performance in detection of subtle interstitial abnormalities.

Takashi Ueguchi1, Takeshi Johkoh, Noriyuki Tomiyama, Osamu Honda, Naoki Mihara, Seiki Hamada, Sachiko Murai, Yuji Ogata, Mitsuhiro Matsumoto, Hironobu Nakamura.   

Abstract

PURPOSE: To compare observer performance in the detection of subtle interstitial abnormalities on 3,520 x 3,520 (4K) matrix and 1,760 x 1,760 (2K) matrix full-size digital storage phosphor (DSP) chest radiographs.
MATERIALS AND METHODS: Thirty-five 4K DSP chest radiographs with subtle interstitial abnormalities (n=27) or normal lungs (n=8) were processed with a half-band low-pass filter to produce 2K DSP radiographs. Although the actual matrix size of the 2K DSP radiographs remained 4K, the effective matrix size was reduced to 2K. Four chest radiologists independently evaluated full-sized hard-copy of the 4K and 2K DSP radiographs, and scored the presence of interstitial abnormalities for both right and left lungs on a five-point confidence scale. With findings on high-resolution computed tomography as the reference standard, observer performance was evaluated using multireader-multicase receiver operating characteristic (ROC) analysis.
RESULTS: The average area under the ROC curve (Az) values for 4K and 2K DSP radiographs were 0.791+/-0.055 and 0.804+/-0.050, respectively. Both individual and averaged Az values showed no statistically significant differences (p>0.05) between 4K and 2K DSP radiographs.
CONCLUSION: Observer performance in the detection of subtle interstitial abnormalities on 4K full-size DSP chest radiographs was equivalent to that on 2K full-size DSP chest radiographs.

Entities:  

Mesh:

Year:  2005        PMID: 15940063

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  5 in total

1.  An ROC study of chest radiographs: 2K Versus 4K high-resolution soft-copy images.

Authors:  Su Young Kim; Yoon Joon Hwang; Yoon Hee Han; Jung Wook Seo; Ji Young Lee; Yong Hoon Kim; Soon Joo Cha; Gham Hur; Sung Soon Lee
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

2.  Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.

Authors:  Claus Koelblinger; Mathias Prokop; Michael Weber; Johannes Sailer; Fabiola Cartes-Zumelzu; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2007-05-10       Impact factor: 5.315

3.  Comparison between differently priced devices for digital capture of X-ray films using computed tomography as a gold standard: a multireader-multicase receiver operating characteristic curve study.

Authors:  Antonio J Salazar; Juan Camilo Camacho; Diego Andrés Aguirre
Journal:  Telemed J E Health       Date:  2011-04-01       Impact factor: 3.536

4.  Comparison between different cost devices for digital capture of X-ray films: an image characteristics detection approach.

Authors:  Antonio José Salazar; Juan Camilo Camacho; Diego Andrés Aguirre
Journal:  J Digit Imaging       Date:  2012-02       Impact factor: 4.056

Review 5.  Digital chest radiography: an update on modern technology, dose containment and control of image quality.

Authors:  Cornelia Schaefer-Prokop; Ulrich Neitzel; Henk W Venema; Martin Uffmann; Mathias Prokop
Journal:  Eur Radiol       Date:  2008-04-23       Impact factor: 5.315

  5 in total