Literature DB >> 15894918

A comparative study of the performance of different corneal topographers on children with respect to orthokeratology practice.

Wan Sang Chui1, Pauline Cho.   

Abstract

PURPOSE: The purpose of this study was to evaluate and compare the performance of three topographers, Medmont E300, Keratron Scout, and Humphrey Atlas 991, for the measurement of corneal parameters of interest in orthokeratology practice on young children.
METHODS: Apical radius (R0), flattest corneal curvature (flat k), eccentricity (e) value, and elevation at 9-mm chord were measured twice on 22 healthy subjects of mean +/- standard deviation (SD) age 11.2 +/- 2.2 years using the topographers under investigation.
RESULTS: The repeatability of the Medmont and Humphrey were good for the measurements of R0 and flat k. The repeatability of the Humphrey was also good for the measurement of e-value. However, for both topographers, the measurement of elevation was not precise enough for orthokeratology empirical lens design. The Keratron showed poor repeatability for all the parameters evaluated. The agreement of the parameters of interest between these instruments was poor.
CONCLUSIONS: The Medmont and the Humphrey showed good repeatability on children, but the precision of elevation measurements was not good enough to be used for designing empiric orthokeratology lenses on children. The Keratron is not recommended to be used on children in orthokeratology fitting and management. Interinstrumental agreements were significantly different and therefore measurements from different topographers should not be used interchangeably.

Entities:  

Mesh:

Year:  2005        PMID: 15894918     DOI: 10.1097/01.opx.0000162642.24885.71

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  7 in total

1.  Videokeratoscopic indices in relation to epidemiological exposure to keratoconus.

Authors:  Jose Luis Mato; Isabel Lema; Elío Díez-Feijoo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-07       Impact factor: 3.117

2.  Study of Theories about Myopia Progression (STAMP) design and baseline data.

Authors:  David A Berntsen; Donald O Mutti; Karla Zadnik
Journal:  Optom Vis Sci       Date:  2010-11       Impact factor: 1.973

3.  Precision and agreement of corneal power measurements obtained using a new corneal topographer OphthaTOP.

Authors:  Jinhai Huang; Giacomo Savini; Hao Chen; Fangjun Bao; Yuanguang Li; Haisi Chen; Weicong Lu; Ye Yu; Qinmei Wang
Journal:  PLoS One       Date:  2015-01-05       Impact factor: 3.240

4.  The normal distribution of corneal eccentricity and its determinants in two rural areas of north and south of Iran.

Authors:  Samira Heydarian; Hassan Hashemi; Fereshteh Shokrollahzadeh; Abbas Ali Yekta; Hadi Ostadimoghaddam; Akbar Derakhshan; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2017-12-06

Review 5.  Orthokeratology: clinical utility and patient perspectives.

Authors:  Jessie Charm
Journal:  Clin Optom (Auckl)       Date:  2017-02-07

6.  The Role of Back Optic Zone Diameter in Myopia Control with Orthokeratology Lenses.

Authors:  Jaume Pauné; Silvia Fonts; Lina Rodríguez; Antonio Queirós
Journal:  J Clin Med       Date:  2021-01-18       Impact factor: 4.241

7.  A comprehensive assessment of the precision and agreement of anterior corneal power measurements obtained using 8 different devices.

Authors:  Qinmei Wang; Giacomo Savini; Kenneth J Hoffer; Zhen Xu; Yifan Feng; Daizong Wen; Yanjun Hua; Feng Yang; Chao Pan; Jinhai Huang
Journal:  PLoS One       Date:  2012-09-25       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.