Literature DB >> 21068276

HIV-1 load comparison using four commercial real-time assays.

Thomas Bourlet1, Anne Signori-Schmuck, Laurent Roche, Vinca Icard, Henia Saoudin, Mary-Anne Trabaud, Jean-Claude Tardy, Patrice Morand, Bruno Pozzetto, René Ecochard, Patrice André.   

Abstract

The HIV-1 RNA viral load is commonly used for the monitoring of disease progression and antiretroviral treatment of HIV-1-infected patients. Since the misestimating of values could lead to inappropriate therapeutical management, the comparative performances, especially the ability to span the genetic diversity of HIV-1, of available automated real-time assays need to be evaluated. We conducted a prospective study with 74 consenting patients enrolled between March 2007 and November 2008. A blood sample was obtained at the time of diagnosis of HIV seropositivity and blindly tested for HIV-1 RNA by at least 4 commercial tests: the Abbott m2000 RealTime HIV-1, bioMérieux NucliSens EasyQ HIV-1, version 1.2 (v1.2), and Cobas AmpliPrep/Cobas TaqMan (CAP/CTM) v1.0 and v2.0 assays. The means of difference were null between CAP/CTM v2.0 and Abbott for CRF02_AG subtypes but positive in favor of CAP/CTM v2.0 for genotype B and negative in favor of NucliSens for all genotypes. The standard deviation (SD) of difference ranged from 0.3 to 0.59, depending on the considered couples of assays. Reliabilities of these four tests, appreciated by the standard deviation of difference between the measurement and the estimated "true" viral load and by the coefficient of reliability, were significantly different (P < 10(-4)) among each other. Significant differences were also observed within each group of HIV-1 genotype. The global disparity was higher for CRF02_AG than for B subtypes. This study indicates a risk of viral load misestimating or discrepancies between techniques, depending on the HIV-1 subtype, and speaks in favor of using the same assay for the monitoring of HIV-1-infected patients.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21068276      PMCID: PMC3020484          DOI: 10.1128/JCM.01688-10

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  20 in total

1.  Multicenter evaluation of the NucliSens EasyQ HIV-1 v1.1 assay for the quantitative detection of HIV-1 RNA in plasma.

Authors:  C de Mendoza; M Koppelman; B Montès; V Ferre; V Soriano; H Cuypers; M Segondy; T Oosterlaken
Journal:  J Virol Methods       Date:  2005-04-25       Impact factor: 2.014

2.  Evaluation of the Roche Cobas TaqMan and Abbott RealTime extraction-quantification systems for HIV-1 subtypes.

Authors:  Marie Gueudin; Jean Christophe Plantier; Véronique Lemée; Marie Paule Schmitt; Loic Chartier; Thomas Bourlet; Annick Ruffault; Florence Damond; Muriel Vray; François Simon
Journal:  J Acquir Immune Defic Syndr       Date:  2007-04-15       Impact factor: 3.731

3.  Increased reporting of detectable plasma HIV-1 RNA levels at the critical threshold of 50 copies per milliliter with the Taqman assay in comparison to the Amplicor assay.

Authors:  Viviane Lima; Richard Harrigan; Julio S G Montaner
Journal:  J Acquir Immune Defic Syndr       Date:  2009-05-01       Impact factor: 3.731

4.  Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT.

Authors:  Priscilla Swanson; Carmen de Mendoza; Yagnya Joshi; Alan Golden; Richard L Hodinka; Vincent Soriano; Sushil G Devare; John Hackett
Journal:  J Clin Microbiol       Date:  2005-08       Impact factor: 5.948

5.  Fully automated quantification of human immunodeficiency virus (HIV) type 1 RNA in human plasma by the COBAS AmpliPrep/COBAS TaqMan system.

Authors:  Wolfram Schumacher; Edmund Frick; Mirko Kauselmann; Viola Maier-Hoyle; Reinier van der Vliet; Reiner Babiel
Journal:  J Clin Virol       Date:  2007-02-27       Impact factor: 3.168

6.  Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 assays.

Authors:  F Damond; B Roquebert; A Bénard; G Collin; M Miceli; P Yéni; F Brun-Vezinet; D Descamps
Journal:  J Clin Microbiol       Date:  2007-08-22       Impact factor: 5.948

Review 7.  Molecular assays for monitoring HIV infection and antiretroviral therapy.

Authors:  Miriam Wittek; Martin Stürmer; Hans Wilhelm Doerr; Annemarie Berger
Journal:  Expert Rev Mol Diagn       Date:  2007-05       Impact factor: 5.225

8.  Performance of three commercial viral load assays, Versant human immunodeficiency virus type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, testing HIV-1 non-B subtypes and recombinant variants.

Authors:  Africa Holguín; Marisa López; Mar Molinero; Vincent Soriano
Journal:  J Clin Microbiol       Date:  2008-07-02       Impact factor: 5.948

Review 9.  HIV-1 viral load assays for resource-limited settings.

Authors:  Susan A Fiscus; Ben Cheng; Suzanne M Crowe; Lisa Demeter; Cheryl Jennings; Veronica Miller; Richard Respess; Wendy Stevens
Journal:  PLoS Med       Date:  2006-10       Impact factor: 11.069

10.  New and old complex recombinant HIV-1 strains among patients with primary infection in 1996-2006 in France: the French ANRS CO06 primo cohort study.

Authors:  Pierre Frange; Julie Galimand; Nicole Vidal; Cécile Goujard; Christiane Deveau; Faouzi Souala; Martine Peeters; Laurence Meyer; Christine Rouzioux; Marie-Laure Chaix
Journal:  Retrovirology       Date:  2008-08-01       Impact factor: 4.602

View more
  16 in total

1.  Comparison of HIV-1 viral load assay performance in immunological stable patients with low or undetectable viremia.

Authors:  Gudrun Naeth; Robert Ehret; Frank Wiesmann; Patrick Braun; Heribert Knechten; Annemarie Berger
Journal:  Med Microbiol Immunol       Date:  2012-06-15       Impact factor: 3.402

2.  Quantification of viral loads lower than 50 copies per milliliter by use of the Cobas AmpliPrep/Cobas TaqMan HIV-1 test, version 2.0, can predict the likelihood of subsequent virological rebound to >50 copies per milliliter.

Authors:  Marta Álvarez Estévez; Natalia Chueca Porcuna; Vicente Guillot Suay; Alejandro Peña Monge; Fernando García García; Leopoldo Muñoz Medina; David Vinuesa García; Jorge Parra Ruiz; Jose Hernández-Quero; Federico García García
Journal:  J Clin Microbiol       Date:  2013-02-06       Impact factor: 5.948

3.  Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load.

Authors:  Orna Mor; Yael Gozlan; Marina Wax; Fernando Mileguir; Avia Rakovsky; Bina Noy; Ella Mendelson; Itzchak Levy
Journal:  J Clin Microbiol       Date:  2015-08-19       Impact factor: 5.948

4.  Comparative performances of HIV-1 RNA load assays at low viral load levels: results of an international collaboration.

Authors:  Luke C Swenson; Bryan Cobb; Anna Maria Geretti; P Richard Harrigan; Mario Poljak; Carole Seguin-Devaux; Chris Verhofstede; Marc Wirden; Alessandra Amendola; Jurg Boni; Thomas Bourlet; Jon B Huder; Jean-Claude Karasi; Snjezana Zidovec Lepej; Maja M Lunar; Odette Mukabayire; Rob Schuurman; Janez Tomazic; Kristel Van Laethem; Linos Vandekerckhove; Annemarie M J Wensing
Journal:  J Clin Microbiol       Date:  2013-12-04       Impact factor: 5.948

5.  Ability of two commercially available assays (Abbott RealTime HIV-1 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Version 2.0) to quantify low HIV-1 RNA Levels (<1,000 copies/milliliter): comparison with clinical samples and NIBSC working reagent for nucleic acid testing assays.

Authors:  Alessandra Amendola; Patrizia Marsella; Maria Bloisi; Federica Forbici; Claudio Angeletti; Maria R Capobianchi
Journal:  J Clin Microbiol       Date:  2014-03-26       Impact factor: 5.948

6.  Cross-platform analysis of HIV-1 RNA data generated by a multicenter assay validation study with wide geographic representation.

Authors:  Cheryl Jennings; Brian Harty; Suzanne Granger; Carrie Wager; John A Crump; Susan A Fiscus; James W Bremer
Journal:  J Clin Microbiol       Date:  2012-06-12       Impact factor: 5.948

7.  Sequencing assays for failed genotyping with the versant hepatitis C virus genotype assay (LiPA), version 2.0.

Authors:  Sylvie Larrat; Jean-Dominique Poveda; Camille Coudret; Katia Fusillier; Nelly Magnat; Anne Signori-Schmuck; Vincent Thibault; Patrice Morand
Journal:  J Clin Microbiol       Date:  2013-04-24       Impact factor: 5.948

8.  Digitally programmable microfluidic automaton for multiscale combinatorial mixing and sample processing.

Authors:  Erik C Jensen; Amanda M Stockton; Thomas N Chiesl; Jungkyu Kim; Abhisek Bera; Richard A Mathies
Journal:  Lab Chip       Date:  2012-11-22       Impact factor: 6.799

Review 9.  Past, present and future molecular diagnosis and characterization of human immunodeficiency virus infections.

Authors:  Yi-Wei Tang; Chin-Yih Ou
Journal:  Emerg Microbes Infect       Date:  2012-08-22       Impact factor: 7.163

Review 10.  Mechanisms and factors that influence high frequency retroviral recombination.

Authors:  Krista Delviks-Frankenberry; Andrea Galli; Olga Nikolaitchik; Helene Mens; Vinay K Pathak; Wei-Shau Hu
Journal:  Viruses       Date:  2011-09-09       Impact factor: 5.818

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.