Literature DB >> 15844152

Higher-order harmonic transmission-line RF coil design for MR applications.

Xiaoliang Zhang1, Xiao-Hong Zhu, Wei Chen.   

Abstract

A novel concept based on the use of higher-order harmonic resonances in a transmission-line resonator is introduced for the design of high-frequency RF coils at high and ultrahigh fields, where conventional RF coil designs present difficulties and limitations. To demonstrate this concept, we successfully designed and fabricated a 400-MHz RF coil for rat imaging using a second-harmonic resonant microstrip transmission line. This coil has a high Q-factor, reduces coil-cable interactions without the use of a matching balun, and has a broad range for tuning the coil's resonant frequency at the loaded condition. This work demonstrates that the use of higher-order harmonics in a transmission-line resonator provides an alternative, efficient approach to the design of large and high-frequency RF coils. Copyright 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 15844152     DOI: 10.1002/mrm.20462

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  34 in total

1.  Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system.

Authors:  Ye Li; Yong Pang; Daniel Vigneron; Orit Glenn; Duan Xu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-01-01

2.  Image homogenization using pre-emphasis method for high field MRI.

Authors:  Ye Li; Chunsheng Wang; Baiying Yu; Daniel Vigneron; Wei Chen; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2013-08

3.  The Need and Initial Practice of Parallel Imaging and Compressed Sensing in Hyperpolarized 13C MRI in vivo.

Authors:  Eugene Milshteyn; Xiaoliang Zhang
Journal:  OMICS J Radiol       Date:  2015-08-05

4.  Stripline resonator and preamplifier for preclinical magnetic resonance imaging at 4.7 T.

Authors:  Ioannis Lavdas; Hugh C Seton; Charles R Harrington; Claude M Wischik
Journal:  MAGMA       Date:  2011-08-04       Impact factor: 2.310

5.  Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Appl Magn Reson       Date:  2014-11-27       Impact factor: 0.831

6.  Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging.

Authors:  Xiaoliang Zhang; Alastair Martin; Caroline Jordan; Prasheel Lillaney; Aaron Losey; Yong Pang; Jeffrey Hu; Mark Wilson; Daniel Cooke; Steven W Hetts
Journal:  Quant Imaging Med Surg       Date:  2017-04

7.  Sensitivity enhancement of traveling wave MRI using free local resonators: an experimental demonstration.

Authors:  Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2017-04

8.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

9.  Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging.

Authors:  Yong Pang; Baiying Yu; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

10.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.