Literature DB >> 15841582

Stability of the implant/abutment joint in a single-tooth external-hexagon implant system: clinical and mechanical review.

Ameen Khraisat1, Osama Abu-Hammad, Awni M Al-Kayed, Najla Dar-Odeh.   

Abstract

Rigorous efforts have recently been made to reduce the recurrence of implant/abutment joint failure in single-tooth implant restorations. However, the current knowledge about the stability of implant/abutment joints in an external hexagon implant system is incomplete. We reviewed clinical data regarding single-tooth implant treatment with Brånemark implants, specifically the CeraOne abutment system (Nobel Biocare AB, Göteborg, Sweden). In vitro studies on joint stability were systematically assessed. Bending overload and the presence of misfit at the implant/abutment joint interface are the critical mechanical conditions that can make the joint unstable. Appropriate joint fitness and proper alignment of the implant should be assessed, and occlusal adjustment by narrowing the restoration width and flattening cuspal inclination should be applied to avoid bending moments caused by the lateral component of occlusal forces. Sufficient clinical reports of longer duration that evaluate and verify longer-term success of the newly manufactured joint components were unavailable.

Entities:  

Mesh:

Year:  2004        PMID: 15841582     DOI: 10.1111/j.1708-8208.2004.tb00038.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  5 in total

1.  Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Authors:  Jae-Young Jo; Dong-Seok Yang; Jung-Bo Huh; Jae-Chan Heo; Mi-Jung Yun; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

2.  Evaluation the loosening of abutment screws in fluid contamination: an in vitro study.

Authors:  Fei Sun; Wei Cheng; Bao-Hong Zhao; Gui-Qiu Song; Zeng Lin
Journal:  Sci Rep       Date:  2022-06-24       Impact factor: 4.996

3.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02

4.  Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment.

Authors:  Rudys Rodolfo de Jesus Tavarez; Wellington Cardoso Bonachela; Anuar Antônio Xible
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

5.  An In Vitro Study of Fluid Contaminations Influences on Reverse Torque Values of Implant-Abutment Connections.

Authors:  Shuying Yang; Yuan Qin; Xueyan Guo; Yaqi Li
Journal:  Biomed Res Int       Date:  2022-03-08       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.