Literature DB >> 15830213

The suprapedicle claw construct in anterior scoliosis surgery.

Vincent Arlet1, Jeffrey Shilt, Jean Ouellet.   

Abstract

Proximal screw pullout is a well-recognized problem in anterior scoliosis surgery, with a rate of pseudarthrosis or screw pullout ranging from 15 to 30%. To prevent screw pullout at the top of the construct, the authors have devised the concept of a claw for the top instrumented vertebra. The claw consists of a classic anterior vertebral body screw inserted parallel to the inferior end-plate and in the posterior portion of the vertebral body 8 mm in front of the spine canal. After rib desarticulation, a laminar hook of a small size is inserted over the superior aspect of the pedicle of the same vertebra. The rod is then inserted into the two side openings of the screw and the hook. Compression across the hook and the screw is then performed, making a claw construct. This concept can also be extended in the case of early revision for a proximal screw pullout, where it is possible to revise the instrumentation with an offset connector linking the rod to the superior portion of the pedicle where the suprapedicule hook has been inserted. We report two cases where a suprapedicle claw was successfully used in anterior scoliosis correction of a right thoracic curve. Such a concept may represent the solution to proximal screw pullout in anterior scoliosis correction.

Entities:  

Mesh:

Year:  2005        PMID: 15830213      PMCID: PMC3489252          DOI: 10.1007/s00586-004-0804-3

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  10 in total

Review 1.  Anterior versus posterior instrumentation for the correction of thoracic idiopathic scoliosis.

Authors:  R R Betz; H Shufflebarger
Journal:  Spine (Phila Pa 1976)       Date:  2001-05-01       Impact factor: 3.468

2.  The use of short and rigid anterior instrumentation in the treatment of idiopathic thoracolumbar scoliosis: a retrospective review of 24 cases.

Authors:  Fabien D Bitan; Michael G Neuwirth; Paul L Kuflik; Andrew Casden; Norman Bloom; Sid Siddiqui
Journal:  Spine (Phila Pa 1976)       Date:  2002-07-15       Impact factor: 3.468

Review 3.  Arterial vascularization of the spinal cord. Recent studies of the anastomotic substitution pathways.

Authors:  G Lazorthes; A Gouaze; J O Zadeh; J J Santini; Y Lazorthes; P Burdin
Journal:  J Neurosurg       Date:  1971-09       Impact factor: 5.115

4.  Pull-out strength of the suprapedicle claw construct: a biomechanical study.

Authors:  Abdulrazzaq Alobaid; Vincent Arlet; Andre Busato; Thomas Steffen
Journal:  Eur Spine J       Date:  2005-04-14       Impact factor: 3.134

5.  Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis.

Authors:  U R Liljenqvist; H F Halm; T M Link
Journal:  Spine (Phila Pa 1976)       Date:  1997-10-01       Impact factor: 3.468

6.  Anterior vertebral body screw pullout testing. A comparison of Zeilke, Kaneda, Universal Spine System, and Universal Spine System with pullout-resistant nut.

Authors:  I H Lieberman; R Khazim; T Woodside
Journal:  Spine (Phila Pa 1976)       Date:  1998-04-15       Impact factor: 3.468

7.  New anterior instrumentation for the management of thoracolumbar and lumbar scoliosis. Application of the Kaneda two-rod system.

Authors:  K Kaneda; Y Shono; S Satoh; K Abumi
Journal:  Spine (Phila Pa 1976)       Date:  1996-05-15       Impact factor: 3.468

8.  Accuracy of pedicular screw placement in vivo.

Authors:  S D Gertzbein; S E Robbins
Journal:  Spine (Phila Pa 1976)       Date:  1990-01       Impact factor: 3.468

9.  Zielke instrumentation (VDS) for the correction of spinal curvature. Analysis of results in 66 patients.

Authors:  J H Moe; G A Purcell; D S Bradford
Journal:  Clin Orthop Relat Res       Date:  1983-11       Impact factor: 4.176

10.  Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis.

Authors:  P Papin; V Arlet; D Marchesi; B Rosenblatt; M Aebi
Journal:  Eur Spine J       Date:  1999       Impact factor: 3.134

  10 in total
  1 in total

1.  Pull-out strength of the suprapedicle claw construct: a biomechanical study.

Authors:  Abdulrazzaq Alobaid; Vincent Arlet; Andre Busato; Thomas Steffen
Journal:  Eur Spine J       Date:  2005-04-14       Impact factor: 3.134

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.