Literature DB >> 10333156

Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis.

P Papin1, V Arlet, D Marchesi, B Rosenblatt, M Aebi.   

Abstract

Utilization of thoracic pedicle screws is controversial, especially in the treatment of scoliosis. We present a case of a 15-year-old girl seen 6 months after her initial surgery for scoliosis done elsewhere. She complained of persistent epigastric pain, tremor of the right foot at rest, and abnormal feelings in her legs. Clinical examination revealed mild weakness in the right lower extremity, a loss of thermoalgic discrimination, and a forward imbalance. A CT scan revealed at T8 and T10 that the right pedicle screws were misplaced by 4 mm in the spinal canal. At the time of the revision surgery the somatosensory evoked potentials (SSEP) returned to normal after screw removal. The clinical symptoms resolved 1 month after the revision. The authors conclude that after pedicle instrumentation at the thoracic level a spinal cord compression should be looked for in case of subtle neurologic findings such as persistent abdominal pain, mild lower extremity weakness, tremor at rest, thermoalgic discrimination loss, or unexplained imbalance.

Entities:  

Mesh:

Year:  1999        PMID: 10333156      PMCID: PMC3611145          DOI: 10.1007/s005860050147

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  24 in total

1.  The suprapedicle claw construct in anterior scoliosis surgery.

Authors:  Vincent Arlet; Jeffrey Shilt; Jean Ouellet
Journal:  Eur Spine J       Date:  2005-04-14       Impact factor: 3.134

2.  A biomechanical analysis of the self-retaining pedicle hook device in posterior spinal fixation.

Authors:  Wilbert van Laar; Rinse J Meester; Theo H Smit; Barend J van Royen
Journal:  Eur Spine J       Date:  2007-01-03       Impact factor: 3.134

3.  Variability of spinal instrumentation configurations in adolescent idiopathic scoliosis.

Authors:  Carl-Eric Aubin; Hubert Labelle; Oana C Ciolofan
Journal:  Eur Spine J       Date:  2006-02-14       Impact factor: 3.134

4.  Financial analysis of circumferential fusion versus posterior-only with thoracic pedicle screw constructs for main thoracic idiopathic curves between 70 degrees and 100 degrees.

Authors:  Scott J Luhmann; Lawrence G Lenke; Yongjung J Kim; Keith H Bridwell; Mario Schootman
Journal:  J Child Orthop       Date:  2008-02-14       Impact factor: 1.548

5.  Are pedicle screw perforation rates influenced by registered or unregistered vertebrae in multilevel registration using a CT-based navigation system in the setting of scoliosis?

Authors:  Masayuki Shimizu; Jun Takahashi; Shota Ikegami; Shugo Kuraishi; Toshimasa Futatsugi; Hiroyuki Kato
Journal:  Eur Spine J       Date:  2014-08-10       Impact factor: 3.134

6.  CT provides precise size assessment of implanted titanium alloy pedicle screws.

Authors:  Michael J Elliott; Joseph B Slakey
Journal:  Clin Orthop Relat Res       Date:  2014-02-11       Impact factor: 4.176

7.  Medially misplaced pedicle screws in patients without neurological deficits following scoliosis surgery: to observe or to remove?

Authors:  Ryo Sugawara; Taichi Tsuji; Toshiki Saito; Ayato Nohara; Kazuki Kawakami; Norikaki Kawakami
Journal:  Eur Spine J       Date:  2015-03-08       Impact factor: 3.134

8.  Complications associated with thoracic pedicle screws in spinal deformity.

Authors:  Gang Li; Guohua Lv; Peter Passias; Michal Kozanek; Umesh S Metkar; Zhongjun Liu; Kirkham B Wood; Lubos Rehak; Youwen Deng
Journal:  Eur Spine J       Date:  2010-03-17       Impact factor: 3.134

9.  Posterior fusion only for thoracic adolescent idiopathic scoliosis of more than 80 degrees: pedicle screws versus hybrid instrumentation.

Authors:  Mario Di Silvestre; Georgios Bakaloudis; Francesco Lolli; Francesco Vommaro; Konstantinos Martikos; Patrizio Parisini
Journal:  Eur Spine J       Date:  2008-08-12       Impact factor: 3.134

10.  Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine.

Authors:  Jean-Marc Mac-Thiong; Hubert Labelle; Marcel Rooze; Véronique Feipel; Carl-Eric Aubin
Journal:  Eur Spine J       Date:  2003-05-29       Impact factor: 3.134