Literature DB >> 20613917

Effect of different polymerization methods on the cytotoxicity of dental composites.

Nilufer Celebi Beriat1, Ahmet Atila Ertan, Senay Canay, Aylin Gurpinar, Mehmet Ali Onur.   

Abstract

OBJECTIVES: The aim of this study was to compare the cytotoxic effects of various dental composites polymerized with two different curing units.
METHODS: Disc-shaped test samples of composites Filtek Z250, Filtek A110, Filtek P60, Filtek Supreme, and SDI Rok were polymerized using one quartz tungsten halogen (QTH) and one light emitting diode (LED) light curing unit (LCU), namely Optilux 501 (QTH) and Elipar Freelight 2 (LED). L-929 mouse fibroblast cultures (3x10(4) cells/ml) were incubated with the samples in 96 well culture plates for evaluation after 8, 24, 48, 72 h. At the end of each period, the cells were counted and examined under a light microscope, and a 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide (MTT) assay was performed. The degree of cytotoxicity for each sample was determined according to the reference value represented by the cells in a control group (a culture without sample).
RESULTS: A significant 3 factor interaction occurred among LCUs, composites, and time factors (P<.005). In general, the test materials cured with the LED LCU demonstrated higher cell survival rates when compared with those cured with halogen LCUs.
CONCLUSIONS: This study shows that polymerization of dental composites with a light emitting diode LCU positively influences the L-929 mouse fibroblast cell viability.

Entities:  

Keywords:  Cytotoxicity; Dental composite; Light curing units

Year:  2010        PMID: 20613917      PMCID: PMC2897862     

Source DB:  PubMed          Journal:  Eur J Dent


INTRODUCTION

Light curing resin composites have been used with increasing frequency as restorative materials and an established alternative to dental amalgam for their aesthetic merits and easy handling. In permanent teeth, dental resin composites are the most important tooth colored filling materials, and in the primary dentition, with its specific conditions, compomers also play an important role. However, the primary problem with composite resin is polymerization shrinkage. Second, insufficient polymerization leads to high residual monomers being released in the oral environment.1 The majority of unreacted components may be released during the first few days. Residual monomers may enter the human body via the skin, oral and gastro intestinal mucosa, dentin, and pulp.2 Their physical properties are constantly improved by manufacturers, and their composition is chemically complex since they contain a great variety of different monomers and additives. The liberation of components from composites may influence the biocompatibility as well as the mechanical properties of the restorations. Generally, they consist of an organic matrix, reinforcing fillers (mainly inorganic), and a silane coupling agent, which connects the inorganic fillers. The organic polymerized matrix is mostly responsible for undesirable effects. In vitro studies show that the polymerization reaction is never complete and that adverse reactions are due to the release of nonpolymerized monomers, such as TEGDMA or Bis-GMA and UDMA.3,4 In most studies, co-monomer TEGDMA has been identified as the main compound released from polymerized resin composites into aqueous media. However, small quantities of monomers Bis-GMA and UDMA and other co-monomers, as well as additives, may also be released. Co-monomer TEGDMA is cytotoxic and inhibits cell growth.3 In the first hours after initial polymerization, unreacted monomers and/or additives are released by solvents or polymer degradation. Therefore, inadequate polymerization is the crucial factor in the release of unreacted monomers. According to Ferracane, approximately 15% to 50% of the methacrylic groups are left unreacted following initial polymerization.5 Although the percentage of unreacted monomers after initial polymerization is lower in new materials, there is still no total conversion during polymerization. The cytotoxic effect on the pulp cells of these unreacted monomers is also dependent on dentin permeability and residual dentin thickness.6 However, these parameters are not directly under the operator’s control. In all methanol extracts from various resin composites, photoinitiator camphoroquinone (CQ) was found. Furthermore, extracts from hybrid resin composites contain photoinitiating substances benzyl (BL) and dimethoxybenzoin (DMBZ). In the extract of one composite, triphenylphosphan (TPP) and triphenylstibane (TPsb) were detected. These substances were used as catalysts.4,7 The success of polymerization depends on the thickness of the filling material, the wavelength of the excitation light, the power density, and the time of irradiation. Tuning between excitation wavelength and the photoinitiator system has a decisive effect on the degree of polymerization. There are various types of light curing units (LCUs) in the dental market, such as quartz tungsten halogen (QTH) and light emitting diode (LED) curing units. QTH units have been used to polymerize composite resin, but the drawback of the halogen unit is a decline in irradiance over time due to aging lamps and filters. A recent alternative to QTH, LED curing units are increasingly used in dental practice. The LED has the advantages of extended of lifetimes of over 10000 h, little degradation of light output over time, and resistance to shock, overheating, and vibration.2 The spectral output of LEDs consists of the absorption peak of CQ (400–500 nm, peak at 470 nm), the most used photoinitiator in resin composites. Comparative studies demonstrated that the type of LCU is an important factor for both curing efficiency and generated heat.8,9 However, few studies have investigated the cytotoxicity of composites with different curing methods. The determination of the possibly toxic effect of composites is a matter of interest. In view of the great variety of LCUs and filling materials currently in use, the question is which combinations cause the least toxic effects. The present study aimed to explore, in an in vitro model, the possible cytotoxicity of various composite–LCU combinations.

MATERIALS AND METHODS

Sample preparation

The A3 shades of composites Filtek P60, Filtek A110, Filtek Supreme, Filtek Z250 (3M ESPE, St. Paul, MN, USA) and SDI Rok (SDI Ltd., Victoria, Australia) were evaluated in this study. The composition of each material is detailed in Table 1. For each material, disc-shaped samples (2 mm diameter and 2 mm in thickness) were prepared using Teflon molds. These molds were placed on flat glass plates on top of Mylar strips (Moyco Union Broach, York, USA) and then filled in bulk with composites. The composites were then covered with an acetate strip and gently pressed with another flat glass plate. Next, excess material was removed with a scalpel (Otto Rüttgers GmBH, Solingen, Germany). The top glass plate was removed to polymerize the samples. The samples were polymerized and randomly divided into two groups (n=6/group) according to the LCU: 1) QTH/40secs (Optilux 501, Kerr, Orange, CA) and 2) LED/20secs (Elipar Freelight II, 3M/ESPE, Seefeld, Germany). The LCUs were all used in standard mode (continuous, constant light intensity). Before photoactivation, the irradiance of both curing units was confirmed with QTH and LED radiometers (Kerr/Demetron, Orange, CA, USA). The output spectrum for the LED was concentrated within the 425–500 nm wavelength range, while that of the Optilux 501 is considerably wider (375–520 nm). However, the spectral flux of the LED was much higher at 425–475 nm, the effective range of CQ the photo-initiator for both resins (Figure 1).
Table 1.

Materials, manufacturers, and approximate resin composition (According to manufacturers’ information).

MaterialLot noManufacturerApproximate resin composition
Filtek Z2502NM3M ESPE, St. Paul, MN, USAFillers (Silane Treated Ceramics)%75–80
Bis-EMA%5–10
Diurethane Dimethacrylate%5–10
Bis-GMA%1–10
Tegdma<%5
Water<%2

Filtek A1100AJ3M ESPE, St. Paul, MN, USAFillers(Silane Treated Silica)%55–65
TEGDMA%15–25
Bis-GMA%15–25
Methacyloxypropyl Methoxysilane Oligomer<%2
Benzoyl Peroxide<%0,3

Filtek P601KE3M ESPE, St. Paul, MN, USAFillers%75–85
Bisphenol A Polyethylene Glycol%5–10
Diether Dimethacrylate
Trimethyl- Diazahexadecanediyl Bismethacrylate%5–10
Methylethylidene Phenyleneoxy Bismethacrylate%1–10
Ethylenedioxydiethyl Dimethacrylate<%5
Water<%2

Filtek Supreme XT5AM3M ESPE, St. Paul, MN, USAFillers (Silane Treated Ceramic And Silica)%65–75(Ceramic)
%5–10 (Silica)
Bis-EMA%5–15
Diurethane Dimethacrylate%5–15
Bis-GMA%1–10
TEGDMA<%5
Water<%2

ROK502102SDI, AustraliaAcrylic Monomer%18–40
Balance Ingredient (Non-Hazardous)%60–82
Figure 1.

Cell viability of the samples polymerized by LED and QTH light curing units.

Cell proliferation

The cells used for the experiment were L929 mouse fibroblasts. The cells were grown as monolayer cultures in 25T-flasks (Corning, NY, USA) in Dulbecco’s Modified Eagle’s Medium/F12 (DMEM/F12) (Sigma Chemical Co. St. Louis, MO, USA) containing 10% fetal calf serum (Biochrom AG, Germany) in a humidified atmosphere of 95% air and 5% CO2 at 37°C. After the 2nd passage, the L929 fibroblastic cell line was plated in 96-well culture plates at an initial density of 30,000 cells/ml with test materials and incubated in the same medium in a humidified atmosphere of 95% air and 5% CO2 at 37°C. One sample was used for each well. Cells cultured without the test materials were used as a control group. L929 cells were incubated for 72h at 37°C. In order to assay the cell proliferation, the cell number was counted at 8h, 24h, 48h, and 72h. At the end of each period, the culture medium was removed, and the cells were collected from the surface of the culture dish using 0.25% trypsin-EDTA (Sigma Chemical Co., St. Louis, MO, USA). L929 cells were counted with trypan blue (Sigma Chemical Co., St. Louis, MO, USA) and examined under a light microscope (Olympus, Kyoto, Germany). Each experiment was repeated 3 times for each test material and control group.

Cell viability assay

The L929 fibroblastic cell line was plated in 96-well culture plates at an initial density of 30,000 cells/ml with test materials and incubated in Dulbecco’s Modified Eagle’s Medium/F12 (DMEM/F12) (Sigma Chemical Co., St. Louis, MO, USA) containing 10% fetal calf serum (Biochrom AG, Germany) in a humidified atmosphere of 95% air and 5% CO2 at 37°C. Cells cultured without the test materials were used as a control group. L929 cells were incubated for 7 days at 37°C. At 8h, 24h, 48h, and 72h, the culture medium was removed from the wells, and 100 μl RPMI-1640-without fenol red (Sigma Chemical Co. St. Louis, MO, USA) containing 12.5 μl MTT (tetrazolium salt 3-[4,5-dimethylthiazol-2-yl]-2,5-diphnyltetrazolium bromide) was added to each well. Culture plates were covered with aluminum foil (Mavipak, Ankara, Turkey), and cells were incubated in the dark for 4h. After the 4h incubation, the MTT solution was removed from the wells, and 100 μl isopropyl alcohol was added. The absorbance at 570 nm was measured using an Ultraviolet visible spectrophotometer (Shimadzu, Tokyo, Japan). The cell viability was calculated according to the following formula: The data were analyzed with SPSS 10.0 statistics program for Windows. The mean, median, minimum, maximum, and standard deviations were calculated. Significance was tested with Kruskall-Wallis, and for multiple comparisons, the Mann Whitney U with Bonferroni correction test was applied.

RESULTS

The method of polymerization affected the cell viability of the materials significantly (P<.05). However, at the 1st time interval (4h), the difference was not significant (Figure 2). The materials that were polymerized with LED curing units became less cytotoxic overall. At the 1st time interval, there was no statistically significant difference among the materials that were polymerized with QTH devices (Figure 3). This was also true for the group that was polymerized with LED curing devices. At the 2nd time interval (24h), there was a statistically significant difference among the materials in the QTH curing group. Filtek P60 had the least cytotoxicity, and Filtek A110, the highest. For the LED curing group, there was no statistically significant difference among materials. At the 3rd time interval (48h), there was a statistically significant difference among materials in the LED group. Filtek Z250 had the least cytotoxicity, and SDI ROK and Filtek Supreme, the highest. There was also a significant difference between the QTH and LED groups at the 3rd time interval. The LED curing group had the least cytotoxicity. In the QTH group, there was a statistically significant difference among materials at the 3rd time interval. Filtek Z250 had the least cytotoxicity, and Filtek Supreme and Filtek P60, the highest. At the 4th time interval (72h), there was a statistically significant difference between the polymerization methods. The LED curing method had the least cytotoxicity. In the LED group, Filtek A110 demonstrated the least cytotoxicity, and Filtek Supreme, the highest. In the QTH group, Filtek Supreme had the least cytotoxicity, and Filtek A110 the highest.
Figure 2.

Cell viability of the samples polymerized by LED.

Figure 3.

Cell viability of the samples polymerized by QTH.

DISCUSSION

The biocompatibility of dental materials has been investigated through different methods.10 In the present study, the effect of resin composites cured with LED or QTH on L-929 fibroblasts was investigated with MTT assay. The MTT assay is a good indicator of cell viability.11 This assay is based on the reduction of the MTT by those cells that remain viable after exposure and incubation with a test chemical or device. Mitochondrial dehydrogenases at the cytochrome b and cytochrome c sites of viable cells convert the yellow water soluble form of the salt to an insoluble, intracellular purple formazon metabolite. A formazon solubilized by extraction with alcohol or DMSO can be quantified spectrophotometrically with results related to the proportion of viable cells.12 In this study, cytotoxicity was evaluated through direct contact between the composite specimen and the cells. In the literature, there are a variety of different in vitro test models for cytotoxicity, including direct contact tests and indirect contact and extract tests.13 In this study, the direct method was preferred because it allowed for a more legitimate comparison between aging intervals, as each set of specimens was statistically independent. However, the important point is to be aware that these strategies may or may not give the same results depending on the materials and measurement times. LCUs affect the degree of conversion depending on the photoinitiator in the resin composite. In literature, there were studies related to the polymerization methods on the cytotoxicity of dental composites suggesting that there were no statistically significant differences between polymerization methods.14 Nevertheless, the results of this study revealed that using LED curing units has a positive effect on cytotoxicity. Although the outcome of this study is in accordance with Sigusch et al,15 other studies indicate that LED curing units may not produce more biocompatible photo-polymerized materials when compared to QTH curing units.16 CQ is an α-dicarbonyl absorbing at 468 nm that is compatible both with LED and QTH curing units. However other photoinitiators, such as phenylpropanedione and diphenyl phosphinoxid, have different absorption spectra; therefore, polymerizing with LED curing units is difficult.17 To avoid polymerization failure when using new resin composites, one must follow the manufacturer’s instructions with respect to the choice of curing unit. In vitro studies evaluating the cytotoxicity of dental composites have indicated moderate to severe cytotoxic effects.11,14,18 In this study, all materials that were tested were severely cytotoxic probably because this test was conducted over a short period. At early intervals, studies indicate that resin containing materials are more cytotoxic than at later intervals. In the literature, the results of in vitro cytotoxicity studies vary according to the material tested, but they are dependent in terms of the cells used for testing.19 In this study, there was no interpretable pattern of cytotoxicity among the restorative materials and time intervals. However, samples polymerized with LED curing units demonstrated less cytotoxicity overall.

CONCLUSIONS

Within the limitations of this study, it can be concluded that polymerization of dental composites with a LED LCU positively influences L-929 mouse fibroblast cell viability.
  19 in total

1.  In vitro cytotoxicity of a composite resin and compomer.

Authors:  C A Quinlan; D M Zisterer; K F Tipton; M I O'Sullivan
Journal:  Int Endod J       Date:  2002-01       Impact factor: 5.264

2.  Influence of different light curing units on the cytotoxicity of various dental composites.

Authors:  Bernd W Sigusch; Andrea Völpel; Ingo Braun; Alexander Uhl; Klaus D Jandt
Journal:  Dent Mater       Date:  2007-01-16       Impact factor: 5.304

3.  The influence of dentine permeability on cytotoxicity of four dentine bonding systems, in vitro.

Authors:  S Bouillaguet; M Virgillito; J Wataha; B Ciucchi; J Holz
Journal:  J Oral Rehabil       Date:  1998-01       Impact factor: 3.837

4.  Genotoxicity of dental materials.

Authors:  J Heil; G Reifferscheid; P Waldmann; G Leyhausen; W Geurtsen
Journal:  Mutat Res       Date:  1996-07-05       Impact factor: 2.433

5.  Fourier transform infrared analysis of degree of polymerization in unfilled resins--methods comparison.

Authors:  J L Ferracane; E H Greener
Journal:  J Dent Res       Date:  1984-08       Impact factor: 6.116

6.  Metabolic effects of dental resin components in vitro detected by NMR spectroscopy.

Authors:  J Engelmann; G Leyhausen; D Leibfritz; W Geurtsen
Journal:  J Dent Res       Date:  2001-03       Impact factor: 6.116

7.  Monomer conversion and cytotoxicity of dental composites irradiated with different modes of photoactivated curing.

Authors:  Wan-Yu Tseng; Chien-Hsun Huang; Ruey-Song Chen; Ming-Shu Lee; Yi-Jane Chen; Frederick A Rueggeberg; Min-Huey Chen
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2007-10       Impact factor: 3.368

8.  Residual monomer/additive release and variability in cytotoxicity of light-curing glass-ionomer cements and compomers.

Authors:  W Geurtsen; W Spahl; G Leyhausen
Journal:  J Dent Res       Date:  1998-12       Impact factor: 6.116

9.  Cytotoxicity of composite resins polymerized with different curing methods.

Authors:  A Nalçaci; M D Oztan; S Yilmaz
Journal:  Int Endod J       Date:  2004-02       Impact factor: 5.264

10.  Second generation LEDs for the polymerization of oral biomaterials.

Authors:  Alexander Uhl; Bernd W Sigusch; Klaus D Jandt
Journal:  Dent Mater       Date:  2004-01       Impact factor: 5.304

View more
  3 in total

Review 1.  Toward dental caries: Exploring nanoparticle-based platforms and calcium phosphate compounds for dental restorative materials.

Authors:  Abdulrahman A Balhaddad; Anmar A Kansara; Denise Hidan; Michael D Weir; Hockin H K Xu; Mary Anne S Melo
Journal:  Bioact Mater       Date:  2018-12-18

2.  The effects of bluephase LED light on fibroblasts.

Authors:  Ana Ivanišević Malčić; Ivan Pavičić; Ivančica Trošić; Paris Simeon; Davor Katanec; Silvana Jukić Krmek
Journal:  Eur J Dent       Date:  2012-07

3.  Does an additional UV LED improve the degree of conversion and Knoop Hardness of light-shade composite resins?

Authors:  Maria Cecília Caldas Giorgi; Flávio Henrique Baggio Aguiar; Luís Eduardo Silva Soares; Airton Abrahão Martin; Priscila Christiane Suzy Liporoni; Luís Alexandre Maffei Sartini Paulillo
Journal:  Eur J Dent       Date:  2012-10
  3 in total