Polymerization depths of contemporary light-curing units using microhardness.

F A Rueggeberg1, J W Ergle, D J Mettenburg.   

Abstract

PURPOSE: This research investigated composite depths of cure using a variety of light-curing units and exposure protocols.
MATERIALS AND METHODS: Composite (Herculite XRV, shade A2, Kerr, Orange, California) was exposed in opaque compules to conventional quartz tungsten halogen (QTH) units, soft-start units, high-intensity QTH and plasma arc (PAC) curing lights, and one argon laser. Cured compules were sonicated to remove uncured composite and were sectioned and polished along the long axis to expose cured composite. Knoop hardness was measured 0.5 mm from the irradiated, top surface and then at 1.0 mm and in 1.0-mm increments until reliable readings could no longer be obtained. Hardness values were compared by analysis of variance at similar depths within a specific curing-light classification, using the hardness of the standard 40-second conventional QTH exposure as comparison (Dunnett's t-test). Depth of cure was defined as the deepest hardness value found equivalent to that at 0.5-mm depth for a specific curing light and scenario.
RESULTS: Conventional QTH lights provided similar hardness profiles. At 2-mm depth, use of a different unit or curing tip made no difference in hardness compared with the standard. At this depth, soft-start (pulse-delay and step-cure) methods yielded hardness similar to that of the standard. High-intensity QTH lights provided similar hardness at 2-mm depth in 10 seconds to that of the standard 40-second exposure. Plasma arc exposure for less than 10 seconds produced inferior hardness compared with the standard. A 10-second PAC and a 5-second laser exposure gave hardness at 2-mm depth equivalent to that of the 40-second standard. Depth of cure for almost all curing scenarios was not greater than 2 mm. CLINICAL SIGNIFICANCE: Similar-type conventional QTH lights with different tip diameter (8 and 12 mm) provide similar composite cure characteristics. Soft-start techniques provide similar cure profiles to those achieved with conventional QTH technique when used according to manufacturer's recommendations. High-intensity QTH units and the argon laser can reduce exposure time while providing composite with similar hardness to that of conventional QTH curing. Plasma arc exposure should be at least of 10 seconds duration to provide hardness equivalent to that achieved with conventional 40-second QTH exposure. Even with consideration of high-intensity curing units, composite increments should still be no greater than 2 mm to provide homogeneous hardness.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 14743529     DOI: 10.1111/j.1708-8240.2000.tb00243.x

Source DB:  PubMed          Journal:  J Esthet Dent        ISSN: 1040-1466


  20 in total

1.  Diode-pumped solid-state laser for bonding orthodontic brackets: effect of light intensity and light-curing time.

Authors:  Young-Oh Kim; Soo-Byung Park; Woo-Sung Son; Ching-Chang Ko; Franklin García-Godoy; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2010-06-08       Impact factor: 3.161

2.  Argon ion laser curing depth effect on a composite resin.

Authors:  Míriam Lacalle Turbino; Luis Carlos Belan; Valéria Soprano; Kátia Martis Rode; Patrícia Ramos Lloret; Michel Nicolau Youssef
Journal:  Lasers Med Sci       Date:  2010-05-28       Impact factor: 3.161

3.  Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure.

Authors:  Anders Lindberg; Anne Peutzfeldt; Jan W V van Dijken
Journal:  Clin Oral Investig       Date:  2005-04-07       Impact factor: 3.573

4.  Comparison of microleakages of photo-cured composites using three different light sources: halogen lamp, LED and argon laser: an in vitro study.

Authors:  M Tielemans; Ph Compere; S O Geerts; M Lamy; M Limme; R J G De Moor; K I M Delmé; M F Bertrand; E Rompen; S Nammour
Journal:  Lasers Med Sci       Date:  2007-11-24       Impact factor: 3.161

5.  The applicability of DPSS laser for light curing of composite resins.

Authors:  Yong Hoon Kwon; Chang-Min Jang; Dong-Hee Shin; Hyo-Joung Seol; Hyung-Il Kim
Journal:  Lasers Med Sci       Date:  2007-09-28       Impact factor: 3.161

6.  Mechanical properties of composite resins light-cured using a blue DPSS laser.

Authors:  Du-Man Baek; Jeong-Kil Park; Sung-Ae Son; Ching-Chang Ko; Franklin Garcia-Godoy; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2012-05-15       Impact factor: 3.161

7.  Curing efficiency of modern LED units.

Authors:  Adam Rencz; Reinhard Hickel; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2011-01-14       Impact factor: 3.573

8.  Effect of a DPSS laser on the shear bond strength of ceramic brackets with different base designs.

Authors:  Mi-Gyoung Park; Jung-Hoon Ro; Jeong-Kil Park; Ching-Chang Ko; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2012-11-08       Impact factor: 3.161

9.  Influence of DPSS laser on polymerization shrinkage and mass change of resin composites.

Authors:  Dong-Hee Shin; Dong-In Yun; Mi-Gyong Park; Ching-Chang Ko; Franklin García-Godoy; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Photomed Laser Surg       Date:  2011-03-21       Impact factor: 2.796

10.  Depth of cure of bulk fill composites with monowave and polywave curing lights.

Authors:  Timothy S Menees; Chee Paul Lin; Dave D Kojic; John O Burgess; Nathaniel C Lawson
Journal:  Am J Dent       Date:  2015-12       Impact factor: 1.522

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.