Literature DB >> 15809957

Radiographic evaluation of a monoblock acetabular component: a multicenter study with 2- to 5-year results.

Thomas A Gruen1, Robert A Poggie, David G Lewallen, Arlen D Hanssen, Randall J Lewis, Thomas J O'Keefe, S David Stulberg, Charles J Sutherland.   

Abstract

Serial radiographs of a porous tantalum monoblock acetabular cup design were evaluated for cup stability and signs of successful osteointegration. Of 574 primary consecutive total hip replacements in 542 patients performed by 9 surgeons at 7 hospitals, 414 cases were available for minimum 2-year follow-up. Follow-up averaged 33 months and ranged from 24 to 58 months. Postoperative radiographs revealed acetabular gaps in 100 zones in 80 (19%) hips: 29 in zone I, 67 in zone II, and 4 in zone III. At last follow-up, 84 (84%) of the zones with gaps completely filled in, and all 4- and 5-mm gaps filled in. There was no progression of any postoperative gap, no evidence of continuous periacetabular interface radiolucencies, no evidence of lysis, and no revisions for loosening. Although these short-term results are encouraging, further follow-up will be required to assess whether the monoblock design and the low modulus of elasticity of porous tantalum will reduce the incidence of periacetabular stress shielding and occurrence of osteolysis.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15809957     DOI: 10.1016/j.arth.2004.12.049

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  29 in total

1.  Treatment of a femoral shaft fracture in a patient with congenital hip disease: a case report.

Authors:  George A Tsakotos; Stefanos D Koutsostathis; George A Macheras
Journal:  J Med Case Rep       Date:  2010-07-22

2.  Uncemented Porous Tantalum Acetabular Components: Early Follow-Up and Failures in 599 Revision Total Hip Arthroplasties.

Authors:  William J Long; Nicolas O Noiseux; Tad M Mabry; Arlen D Hanssen; David G Lewallen
Journal:  Iowa Orthop J       Date:  2015

3.  Trabecular Metal cups for acetabular defects with 50% or less host bone contact.

Authors:  Dror Lakstein; David Backstein; Oleg Safir; Yona Kosashvili; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2009-03-10       Impact factor: 4.176

4.  The development of a scanning strategy for the manufacture of porous biomaterials by selective laser melting.

Authors:  R Stamp; P Fox; W O'Neill; E Jones; C Sutcliffe
Journal:  J Mater Sci Mater Med       Date:  2009-06-18       Impact factor: 3.896

5.  Multicentre use of a porous tantalum monoblock acetabular component.

Authors:  Th A Xenakis; G A Macheras; K S Stafilas; A T Kostakos; K Bargiotas; K N Malizos
Journal:  Int Orthop       Date:  2008-05-29       Impact factor: 3.075

6.  Do tantalum and titanium cups show similar results in revision hip arthroplasty?

Authors:  S Mehdi Jafari; Benjamin Bender; Catelyn Coyle; Javad Parvizi; Peter F Sharkey; William J Hozack
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

7.  Smoking may be a harbinger of early failure with ultraporous metal acetabular reconstruction.

Authors:  Adolph V Lombardi; Keith R Berend; Joanne B Adams; Ryan C Jefferson; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

8.  Clinical and radiological outcomes of trabecular metal systems and antiprotrusion cages in acetabular revision surgery with severe defects: a comparative study.

Authors:  Irene Isabel López-Torres; Pablo Sanz-Ruíz; Coral Sánchez-Pérez; Ricardo Andrade-Albarracín; Javier Vaquero
Journal:  Int Orthop       Date:  2018-02-26       Impact factor: 3.075

9.  Survivorship of monoblock trabecular metal cups in primary THA : midterm results.

Authors:  Konstantinos N Malizos; Konstantinos Bargiotas; Loukia Papatheodorou; Michael Hantes; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

10.  Analysis of bone ingrowth on a tantalum cup.

Authors:  F D'Angelo; L Murena; M Campagnolo; G Zatti; P Cherubino
Journal:  Indian J Orthop       Date:  2008-07       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.