Literature DB >> 15805951

Computer-assisted navigation increases precision of component placement in total knee arthroplasty.

Rolf G Haaker1, Martin Stockheim, Michael Kamp, Gunnar Proff, Johannes Breitenfelder, Andreas Ottersbach.   

Abstract

UNLABELLED: In our clinical study, 200 total knee arthroplasties were evaluated to compare the use of the OrthoPilot system with conventional mechanical instrumentation. Long-term outcome of total knee replacement depends mainly on the accuracy of implant positioning and restoration of the mechanical leg axis. Our experience was that navigation could achieve a greater degree of accuracy concerning the aforementioned aspects. Among 513 primary-inserted total knee replacements, 100 navigated knees were compared with 100 conventionally implanted knees after matching the two groups of patients by gender, body mass index, age, preoperative deformities, radiographic findings, and operating time. Three weeks after surgery, the radiographic results were significantly better in the computer-assisted group compared with the results in the conventional group when we assessed component positioning in four axes. Only the sagittal tibial component angle was not significantly different. Total knee arthroplasty using the OrthoPilot system led to increased precision of tibial and femoral component positioning in comparison with hand-guided replacement surgery. An additional 10 minutes of operating time was acceptable. Navigation-specific complications were not seen, and the number of outliers decreased. Because computer navigation in orthopaedics is a new technology, data regarding long-term outcomes are not available. LEVEL OF EVIDENCE: Diagnostic study, Level II-1 (retrospective study). See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2005        PMID: 15805951     DOI: 10.1097/01.blo.0000150564.31880.c4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  80 in total

Review 1.  Computer assisted navigation in knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song
Journal:  Clin Orthop Surg       Date:  2011-12-01

2.  Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty.

Authors:  R Iorio; G Bolle; F Conteduca; L Valeo; J Conteduca; D Mazza; A Ferretti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-24       Impact factor: 4.342

3.  Feasibility of computer-assisted surgery for trapeziometacarpal prosthesis: a preliminary experimental study.

Authors:  Sybille Facca; Philippe A Liverneaux
Journal:  Surg Radiol Anat       Date:  2012-04-25       Impact factor: 1.246

4.  Centre of the posterior cruciate ligament and the sulcus between tubercle spines are reliable landmarks for tibial component placement.

Authors:  Namık Sahin; Teoman Atıcı; Ünal Kurtoğlu; Ali Turgut; Güven Ozkaya; Yüksel Ozkan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-03       Impact factor: 4.342

5.  No difference in ROM and knee function between mobile and floating platforms in TKA.

Authors:  Johannes Holinka; Navid Bahrami; Richard Lass; Sophie Frantal; Reinhard Windhager; Hugo Axel Wanivenhaus
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-29       Impact factor: 4.342

6.  Effect of preoperative deformity on postoperative leg axis in total knee arthroplasty: a prospective randomized study.

Authors:  Wei-Hsiu Hsu; Robert Wen Wei Hsu; Yi-Jan Weng
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-04-27       Impact factor: 4.342

7.  Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies.

Authors:  Yaron S Brin; Vassilios S Nikolaou; Lawrence Joseph; David J Zukor; John Antoniou
Journal:  Int Orthop       Date:  2010-04-08       Impact factor: 3.075

8.  [CAS-guided correction arthrodesis of the tarsometatarsal and midfoot joints].

Authors:  M Richter
Journal:  Oper Orthop Traumatol       Date:  2011-10       Impact factor: 1.154

9.  [Computer-assisted surgery-(CAS-)guided correction arthrodesis of the subtalar joint].

Authors:  Martinus Richter
Journal:  Oper Orthop Traumatol       Date:  2010-10       Impact factor: 1.154

10.  Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty.

Authors:  Jae Han Ko; Chang Dong Han; Kyoo Ho Shin; Levis Nguku; Ick Hwan Yang; Woo Suk Lee; Kwang Il Kim; Kwan Kyu Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-18       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.