Literature DB >> 22532375

Feasibility of computer-assisted surgery for trapeziometacarpal prosthesis: a preliminary experimental study.

Sybille Facca1, Philippe A Liverneaux.   

Abstract

BACKGROUNDS: The main complication of trapeziometacarpal replacement is trapezial cup loosening due to an imperfect positioning of the trapezial component. This problem is quite similar to those related to other arthroplasties. Hip surgery was progressed toward computer-assisted surgery (CAS) for the improvement of acetabular cup positioning. In this study, we propose an analysis of the feasibility of CAS in trapeziometacarpal replacement.
METHODS: We implanted the hand of a cadaver with a trapeziometacarpal prosthesis (Elektra, by SBI). The surgical procedure and the analysis of motion with CAS were carried out in 6 steps: incision, bone morphing preparation and initialisation, trapezial and metacarpal recordings, first kinematic analysis, prosthesis insertion, and second kinematic analysis. The evaluation of the results was carried out as the comparison of the 2 curves sequences before and after prosthesis insertion.
RESULTS: We did not notice any dislocation of the prosthesis. The comparison of 2 curves showed differences regarding motion. For instance, as for abduction-adduction movements, before prosthesis insertion, an opposed-phase automatic rotation was clearly observed whereas after prosthesis insertion, no rotation was observed.
CONCLUSION: CAS makes it possible to analyze the trapeziometacarpal joint motion in terms of biomechanics rather than in terms of anatomy. Such progress should result in measurement standardization that in turn should improve the positioning of prostheses and perhaps the lengthening of their life expectancy by decreasing the rates of prosthesis loosening.

Entities:  

Mesh:

Year:  2012        PMID: 22532375     DOI: 10.1007/s00276-012-0972-5

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  18 in total

1.  The axes of rotation of the thumb carpometacarpal joint.

Authors:  A Hollister; W L Buford; L M Myers; D J Giurintano; A Novick
Journal:  J Orthop Res       Date:  1992-05       Impact factor: 3.494

2.  Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study.

Authors:  S David Stulberg; Mark A Yaffe; Samuel S Koo
Journal:  J Bone Joint Surg Am       Date:  2006-12       Impact factor: 5.284

3.  [Navigation for placement of scaphoid screws : a new indication for intraoperative 3D navigation-a cadaver study].

Authors:  D Kendoff; M Citak; R Gaulke; M J Gardner; J Geerling; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2007-09       Impact factor: 1.000

4.  CMC arthroplasty of the thumb: a review.

Authors:  Kristofer S Matullo; Asif Ilyas; Joseph J Thoder
Journal:  Hand (N Y)       Date:  2007-08-07

5.  Kirschner wire placement in scaphoid bones using fluoroscopic navigation: a cadaver study comparing conventional techniques with navigation.

Authors:  Philippe A Liverneaux; Anes Gherissi; Matthieu Beustes Stefanelli
Journal:  Int J Med Robot       Date:  2008-06       Impact factor: 2.547

6.  The future of robotics in hand surgery.

Authors:  P Liverneaux; E Nectoux; C Taleb
Journal:  Chir Main       Date:  2009-08-29

7.  Contribution of computer-assisted surgery in total wrist prosthesis: a comparative preliminary study of eight cases.

Authors:  Sybille Facca; Anes Gherissi; Philippe A Liverneaux
Journal:  Int J Med Robot       Date:  2010-06       Impact factor: 2.547

8.  A retrospective review of 115 cases of surgically-treated trapeziometacarpal osteoarthritis.

Authors:  J Y Alnot; G P Muller
Journal:  Rev Rhum Engl Ed       Date:  1998-02

9.  A joint coordinate system proposal for the study of the trapeziometacarpal joint kinematics.

Authors:  L Cheze; R Dumas; J J Comtet; C Rumelhart; M Fayet
Journal:  Comput Methods Biomech Biomed Engin       Date:  2009-06       Impact factor: 1.763

10.  Second generation GUEPAR total arthroplasty of the thumb basal joint: 50 months follow-up in 84 cases.

Authors:  S Lemoine; G Wavreille; J Y Alnot; C Fontaine; C Chantelot
Journal:  Orthop Traumatol Surg Res       Date:  2009-02-18       Impact factor: 2.256

View more
  2 in total

1.  Optimal Center of Rotation for Ball-And-Socket Thumb Carpometacarpal Arthroplasty Identified Using Three-Dimensional Kinematic Analysis: A Pilot Study.

Authors:  Atsuro Murai; Akihiro Kurosawa; Kaoru Tada; Hiroshi Tachiya; Atsuya Tamai; Mika Akahane; Masashi Matsuta; Yuta Nakamura; Hiroki Kawashima; Hiroyuki Tsuchiya
Journal:  Front Bioeng Biotechnol       Date:  2022-06-01

Review 2.  Thumb CMCJ prosthetic total joint replacement: a systematic review.

Authors:  Thomas J Holme; Marta Karbowiak; Jennifer Clements; Ritesh Sharma; Johnathan Craik; Najab Ellahee
Journal:  EFORT Open Rev       Date:  2021-05-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.