Literature DB >> 12754069

Lateral resolution in elastography.

Raffaella Righetti1, Seshadri Srinivasan, Jonathan Ophir.   

Abstract

The factors that control the lateral resolution in elastography were investigated using a simulation study. The lateral resolution was estimated from the simulated axial strain elastograms as the smallest measurable distance between two equally stiff lesions embedded in a homogeneously softer background. The lesions were symmetrically positioned lateral to the center of the target, at the focus of the transducer. Ultrasound (US) systems with different transducer frequencies, bandwidths and f-numbers were simulated. The effects of the ultrasonic parameters, the lateral spacing between adjacent echo signals, the cross-correlation window length, the lesion/background elastic contrast and the lateral motion of scatterers on the estimated lateral resolution were investigated. The results show that the lateral resolution in elastography is proportional to the beam width of the US system used to acquire the data, and is on the same order as the sonographic lateral resolution.

Mesh:

Year:  2003        PMID: 12754069     DOI: 10.1016/s0301-5629(03)00028-0

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  15 in total

1.  Linear approach to axial resolution in elasticity imaging.

Authors:  Jie Liu; Craig K Abbey; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-06       Impact factor: 2.725

2.  Coded pulse excitation for ultrasonic strain imaging.

Authors:  Jie Liu; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-02       Impact factor: 2.725

Review 3.  Medical ultrasound: imaging of soft tissue strain and elasticity.

Authors:  Peter N T Wells; Hai-Dong Liang
Journal:  J R Soc Interface       Date:  2011-06-16       Impact factor: 4.118

4.  High-resolution harmonic motion imaging (HR-HMI) for tissue biomechanical property characterization.

Authors:  Teng Ma; Xuejun Qian; Chi Tat Chiu; Mingyue Yu; Hayong Jung; Yao-Sheng Tung; K Kirk Shung; Qifa Zhou
Journal:  Quant Imaging Med Surg       Date:  2015-02

5.  Normal and shear strain imaging using 2D deformation tracking on beam steered linear array datasets.

Authors:  Haiyan Xu; Tomy Varghese
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

6.  Photoacoustic tomography of vascular compliance in humans.

Authors:  Pengfei Hai; Yong Zhou; Jinyang Liang; Chiye Li; Lihong V Wang
Journal:  J Biomed Opt       Date:  2015       Impact factor: 3.170

7.  Tendon motion and strain patterns evaluated with two-dimensional ultrasound elastography.

Authors:  Laura A Chernak; Darryl G Thelen
Journal:  J Biomech       Date:  2012-08-28       Impact factor: 2.712

8.  High-resolution acoustic-radiation-force-impulse imaging for assessing corneal sclerosis.

Authors:  Cho-Chiang Shih; Chih-Chung Huang; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Med Imaging       Date:  2013-04-08       Impact factor: 10.048

9.  A comparison between unfocused and focused transmit strategies in cardiac strain imaging.

Authors:  Vincent Sayseng; Julien Grondin; Rachel A Weber; Elisa Konofagou
Journal:  Phys Med Biol       Date:  2020-01-24       Impact factor: 3.609

10.  Ultrasonic characterization of the nonlinear properties of canine livers by measuring shear wave speed and axial strain with increasing portal venous pressure.

Authors:  Veronica Rotemberg; Brett Byram; Mark Palmeri; Michael Wang; Kathryn Nightingale
Journal:  J Biomech       Date:  2013-05-30       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.