Literature DB >> 22222689

Inherent correction of motion-induced phase errors in multishot spiral diffusion-weighted imaging.

Trong-Kha Truong1, Nan-kuei Chen, Allen W Song.   

Abstract

Multishot spiral imaging is a promising alternative to echo-planar imaging for high-resolution diffusion-weighted imaging and diffusion tensor imaging. However, subject motion in the presence of diffusion-weighting gradients causes phase inconsistencies among different shots, resulting in signal loss and aliasing artifacts in the reconstructed images. Such artifacts can be reduced using a variable-density spiral trajectory or a navigator echo, however at the cost of a longer scan time. Here, a novel iterative phase correction method is proposed to inherently correct for the motion-induced phase errors without requiring any additional scan time. In this initial study, numerical simulations and in vivo experiments are performed to demonstrate that the proposed method can effectively and efficiently correct for spatially linear phase errors caused by rigid-body motion in multishot spiral diffusion-weighted imaging of the human brain.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22222689      PMCID: PMC3323687          DOI: 10.1002/mrm.24124

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Anisotropy in high angular resolution diffusion-weighted MRI.

Authors:  L R Frank
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

2.  Fast spiral coronary artery imaging.

Authors:  C H Meyer; B S Hu; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

3.  High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions.

Authors:  Tie-Qiang Li; Dong-Hyun Kim; Michael E Moseley
Journal:  J Magn Reson Imaging       Date:  2005-04       Impact factor: 4.813

4.  High-resolution diffusion tensor imaging of the human pons with a reduced field-of-view, multishot, variable-density, spiral acquisition at 3 T.

Authors:  Dimitrios C Karampinos; Anh T Van; William C Olivero; John G Georgiadis; Bradley P Sutton
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

5.  K-space and image-space combination for motion-induced phase-error correction in self-navigated multicoil multishot DWI.

Authors:  Anh T Van; Dimitrios C Karampinos; John G Georgiadis; Bradley P Sutton
Journal:  IEEE Trans Med Imaging       Date:  2009-11       Impact factor: 10.048

6.  Dynamic correction of artifacts due to susceptibility effects and time-varying eddy currents in diffusion tensor imaging.

Authors:  Trong-Kha Truong; Nan-kuei Chen; Allen W Song
Journal:  Neuroimage       Date:  2011-06-14       Impact factor: 6.556

7.  Motion-induced phase error estimation and correction in 3D diffusion tensor imaging.

Authors:  Anh T Van; Diego Hernando; Bradley P Sutton
Journal:  IEEE Trans Med Imaging       Date:  2011-06-07       Impact factor: 10.048

8.  Diffusion-weighted multiple shot echo planar imaging of humans without navigation.

Authors:  M D Robson; A W Anderson; J C Gore
Journal:  Magn Reson Med       Date:  1997-07       Impact factor: 4.668

9.  High efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE).

Authors:  Lawrence R Frank; Youngkyoo Jung; Souheil Inati; J Michael Tyszka; Eric C Wong
Journal:  Neuroimage       Date:  2009-09-22       Impact factor: 6.556

10.  Analysis and correction of motion artifacts in diffusion weighted imaging.

Authors:  A W Anderson; J C Gore
Journal:  Magn Reson Med       Date:  1994-09       Impact factor: 4.668

View more
  5 in total

1.  High spatial resolution diffusion weighted imaging on clinical 3 T MRI scanners using multislab spiral acquisitions.

Authors:  Joseph L Holtrop; Bradley P Sutton
Journal:  J Med Imaging (Bellingham)       Date:  2016-04-12

2.  High-resolution multishot spiral diffusion tensor imaging with inherent correction of motion-induced phase errors.

Authors:  Trong-Kha Truong; Arnaud Guidon
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

3.  Spatially resolved kinetics of skeletal muscle exercise response and recovery with multiple echo diffusion tensor imaging (MEDITI): a feasibility study.

Authors:  E E Sigmund; S H Baete; K Patel; D Wang; D Stoffel; R Otazo; P Parasoglou; J Bencardino
Journal:  MAGMA       Date:  2018-05-14       Impact factor: 2.310

4.  Cortical depth dependence of the diffusion anisotropy in the human cortical gray matter in vivo.

Authors:  Trong-Kha Truong; Arnaud Guidon; Allen W Song
Journal:  PLoS One       Date:  2014-03-07       Impact factor: 3.240

5.  A diffusion-matched principal component analysis (DM-PCA) based two-channel denoising procedure for high-resolution diffusion-weighted MRI.

Authors:  Nan-Kuei Chen; Hing-Chiu Chang; Ali Bilgin; Adam Bernstein; Theodore P Trouard
Journal:  PLoS One       Date:  2018-04-25       Impact factor: 3.752

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.