Abstract

Acquisition time plays a key role in the quality of cardiac multidetector computed tomography (MDCT) and is directly related to the rotation time of the scanner. The purpose of this study is to examine the influence of heart rate and a multisector reconstruction algorithm on the image quality of coronary arteries of an anthropomorphic adjustable moving heart phantom on an ECG-gated MDCT unit. The heart phantom and a coronary artery phantom were used on a MDCT unit with a rotation time of 500 ms. The movement of the heart was determined by analysis of the images taken at different phases. The results indicate that the movement of the coronary arteries on the heart phantom is comparable to that in a clinical setting. The influence of the heart rate on image quality and artifacts was determined by analysis of several heart rates between 40 and 80 bpm where the movement of the heart was synchronized using a retrospective ECG-gated acquisition protocol. The resulting reformatted volume rendering images of the moving heart and the coronary arteries were qualitatively compared as a result of the heart rate. The evaluation was performed on three independent series by two independent radiologists for the image quality of the coronary arteries and the presence of artifacts. The evaluation shows that at heart rates above 50 bpm the influence of motion artifacts in the coronary arteries becomes apparent. In addition the influence of a dedicated multisector reconstruction technique on image quality was determined. The results show that the image quality of the coronary arteries is not only related to the heart rate and that the influence of the multisector reconstruction technique becomes significant above 70 bpm. Therefore, this study proves that from the actual acquisition time per heart cycle one cannot determine an actual acquisition time, but only a mathematical acquisition time.

Mesh:

Year:  2005        PMID: 15776244     DOI: 10.1007/s00330-004-2602-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  26 in total

1.  Motion artifacts in subsecond conventional CT and electron-beam CT: pictorial demonstration of temporal resolution.

Authors:  C H McCollough; M R Bruesewitz; T R Daly; F E Zink
Journal:  Radiographics       Date:  2000 Nov-Dec       Impact factor: 5.333

2.  Optimal ECG trigger point in electron-beam CT studies: three methods for minimizing motion artifacts.

Authors:  S Mao; M J Budoff; L Bin; S C Liu
Journal:  Acad Radiol       Date:  2001-11       Impact factor: 3.173

3.  Do segmented reconstruction algorithms for cardiac multi-slice computed tomography improve image quality?

Authors:  Sandra S Halliburton; Arthur E Stillman; Thomas Flohr; Bernd Ohnesorge; Nancy Obuchowski; Michael Lieber; Wadih Karim; Stacie A Kuzmiak; Jane M Kasper; Richard D White
Journal:  Herz       Date:  2003-02       Impact factor: 1.443

4.  Comparative study with a moving heart phantom of the impact of temporal resolution on image quality with two multidetector electrocardiography-gated computed tomography units.

Authors:  Stephan Wicky; Michael Rosol; Udo Hoffmann; Michael Graziano; Kent E Yucel; Thomas J Brady
Journal:  J Comput Assist Tomogr       Date:  2003 May-Jun       Impact factor: 1.826

5.  Coronary artery motion during the cardiac cycle and optimal ECG triggering for coronary artery imaging.

Authors:  B Lu; S S Mao; N Zhuang; H Bakhsheshi; H Yamamoto; J Takasu; S C Liu; M J Budoff
Journal:  Invest Radiol       Date:  2001-05       Impact factor: 6.016

6.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

7.  Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients.

Authors:  Stephen Schroeder; Andreas F Kopp; Axel Kuettner; Christof Burgstahler; Christian Herdeg; Martin Heuschmid; Andreas Baumbach; Claus D Claussen; Karl R Karsch; Ludger Seipel
Journal:  Clin Imaging       Date:  2002 Mar-Apr       Impact factor: 1.605

8.  A rosetta stone for coronary calcium risk stratification: agatston, volume, and mass scores in 11,490 individuals.

Authors:  John A Rumberger; Leon Kaufman
Journal:  AJR Am J Roentgenol       Date:  2003-09       Impact factor: 3.959

9.  Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating.

Authors:  Tobias F Jakobs; Bernd J Wintersperger; Peter Herzog; Thomas Flohr; Christoph Suess; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2003-05-21       Impact factor: 5.315

10.  Measurement of the RT interval on ECG records during electron-beam CT.

Authors:  Songshou Mao; Bin Lu; Junichiro Takasu; Ronald J Oudiz; Matthew J Budoff
Journal:  Acad Radiol       Date:  2003-06       Impact factor: 3.173

View more
  13 in total

1.  Preoperative assessment and follow-up of congenital abnormalities of the pulmonary arteries using CT and MRI.

Authors:  Sebastian Ley; Julia Zaporozhan; Raoul Arnold; Joachim Eichhorn; Jens-Peter Schenk; Herbert Ulmer; Karl-Friedrich Kreitner; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2006-06-24       Impact factor: 5.315

2.  Characterization of 3-D coronary tree motion from MSCT angiography.

Authors:  Guanyu Yang; Jian Zhou; Dominique Boulmier; Marie-Paule Garcia; Limin Luo; Christine Toumoulin
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-09-25

3.  Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model.

Authors:  Shian-Chao Tay; Andrew N Primak; Joel G Fletcher; Bernhard Schmidt; Kimberly K Amrami; Richard A Berger; Cynthia H McCollough
Journal:  Skeletal Radiol       Date:  2007-09-06       Impact factor: 2.199

4.  A model for temporal resolution of multidetector computed tomography of coronary arteries in relation to rotation time, heart rate and reconstruction algorithm.

Authors:  M J W Greuter; T Flohr; P M A van Ooijen; M Oudkerk
Journal:  Eur Radiol       Date:  2006-04-27       Impact factor: 5.315

5.  Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography.

Authors:  Stephanie Busch; Thorsten R C Johnson; Konstantin Nikolaou; Franz von Ziegler; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-12-16       Impact factor: 5.315

6.  The impact of motion artifacts on the reproducibility of repeated coronary artery calcium measurements.

Authors:  Jun Horiguchi; Hiroshi Fukuda; Hideya Yamamoto; Nobuhiko Hirai; Farzana Alam; Hideaki Kakizawa; Masashi Hieda; Toshihiro Tachikake; Kazushi Marukawa; Katsuhide Ito
Journal:  Eur Radiol       Date:  2006-05-23       Impact factor: 5.315

7.  Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64.

Authors:  Julie M Miller; Marc Dewey; Andrea L Vavere; Carlos E Rochitte; Hiroyuki Niinuma; Armin Arbab-Zadeh; Narinder Paul; John Hoe; Albert de Roos; Kunihiro Yoshioka; Pedro A Lemos; David E Bush; Albert C Lardo; John Texter; Jeffery Brinker; Christopher Cox; Melvin E Clouse; João A C Lima
Journal:  Eur Radiol       Date:  2008-11-08       Impact factor: 5.315

8.  A new approach to the assessment of lumen visibility of coronary artery stent at various heart rates using 64-slice MDCT.

Authors:  J M Groen; M J W Greuter; P M A van Ooijen; M Oudkerk
Journal:  Eur Radiol       Date:  2007-02-16       Impact factor: 5.315

9.  Quantitative image analysis for the detection of motion artefacts in coronary artery computed tomography.

Authors:  Wisnumurti Kristanto; Peter M van Ooijen; Riksta Dikkers; Marcel J Greuter; Felix Zijlstra; Matthijs Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2009-09-23       Impact factor: 2.357

10.  Comparison of MRI, 64-slice MDCT and DSCT in assessing functional cardiac parameters of a moving heart phantom.

Authors:  J M Groen; P A van der Vleuten; M J W Greuter; F Zijlstra; M Oudkerk
Journal:  Eur Radiol       Date:  2008-10-25       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.