Radiation-absorbed dose from 201Tl-thallous chloride.

Stephen R Thomas1, Michael G Stabin, Frank P Castronovo.   

Abstract

UNLABELLED: Revised radiation dosimetry estimates for 201Tl-thallous chloride have been developed using new data specifically acquired to address the issue of testicular uptake of this agent and through reevaluation of extant data for biodistribution in other organs.
METHODS: Quantitative testicular scintigraphy data of sequestered testes (body-background shielded) were obtained from 28 patients (56 studies) injected with 201Tl-thallous chloride at peak exercise. Previously published data for 15 patients injected at maximal exercise were reanalyzed to obtain updated biodistribution parameters for designated organs. Radiation dose was calculated according to the MIRD schema. Radiation dose to testes as a function of age was determined. Comparisons are made between organ dose estimates derived in this study and those previously published. The dose contributions of possible contaminants (200Tl, 202Tl, 203Pb) have been included. Estimates are provided of the dose component from these contaminants if injected at the time of the maximum recommended 5-d shelf life (as opposed to at the designated calibration time).
RESULTS: The radiation dose per unit administered activity to adult testes calculated in this study of 0.21 mGy/MBq (0.77 rad/mCi) is approximately a factor of 2 less than the value of 0.45 mGy/MBq (1.7 rad/mCi) previously accepted. The revised dose estimates for other organs show less variation from published values. The effective dose determined in this work is approximately 0.16 mSv/MBq (0.60 rem/mCi). Under the assumption of similar biokinetics as for the adult, the testes dose for children increases significantly as age decreases with a value of 7.5 mGy/MBq (28 rad/mCi) for a newborn. Contributions from radiocontaminants that may be encountered in the preparation of 201Tl-thallous chloride are shown to range from a fraction of a percent up to approximately 20% of the total dose for some organs, with the higher values arising from the long half-life contaminant 202Tl after a 5-d shelf life.
CONCLUSION: It is recommended that the dose values determined in this study be used when estimating the radiation dose to the adult testes from intravenous administration of 201Tl-thallous chloride. The potential for increased radiation dose per administered activity to the testes at younger ages should be evaluated before performing procedures on children. The presence of radiocontaminants in the product should be considered when estimating radiation dose and may add a significant contribution to dose dependent on the specific radionuclide and concentration at the time of administration.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15750165

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  7 in total

1.  Tl-201 stress tests and homeland security.

Authors:  Lawrence T Dauer; Matthew J Williamson; Jean St Germain; H William Strauss
Journal:  J Nucl Cardiol       Date:  2007-07-02       Impact factor: 5.952

2.  Degradation of myocardial perfusion SPECT images caused by contaminants in thallous (201Tl) chloride.

Authors:  Steven G Staelens; Tim C de Wit; Ignace A Lemahieu; Freek J Beekman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-25       Impact factor: 9.236

3.  Finding sensitive parameters in internal dose calculations for radiopharmaceuticals commonly used in clinical nuclear medicine.

Authors:  Vladimir Spielmann; Wei Bo Li; Maria Zankl
Journal:  Radiat Environ Biophys       Date:  2018-06-29       Impact factor: 1.925

4.  Choice strategy of different dose-saving protocols in 64-slice MDCT coronary angiography.

Authors:  R Malagò; M D'Onofrio; I Baglio; S Brunelli; D Tavella; F Beltrame; P Benussi; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2009-08-07       Impact factor: 3.469

5.  Stress thallium-201/rest technetium-99m sequential dual-isotope high-speed myocardial perfusion imaging validation versus invasive coronary angiography.

Authors:  Gilles Barone-Rochette; Mélanie Leclere; Alex Calizzano; Estelle Vautrin; Gallazzini-Crepin Céline; Alexis Broisat; Catherine Ghezzi; Jean Philippe Baguet; Jacques Machecourt; Gérald Vanzetto; Daniel Fagret
Journal:  J Nucl Cardiol       Date:  2014-11-08       Impact factor: 5.952

6.  Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography.

Authors:  Anja Deetjen; Susanne Möllmann; Guido Conradi; Andreas Rolf; Axel Schmermund; Christian W Hamm; Thorsten Dill
Journal:  Heart       Date:  2007-03-29       Impact factor: 5.994

Review 7.  Biokinetics and dosimetry of commonly used radiopharmaceuticals in diagnostic nuclear medicine - a review.

Authors:  Uta Eberlein; Jörn Hendrik Bröer; Charlot Vandevoorde; Paula Santos; Manuel Bardiès; Klaus Bacher; Dietmar Nosske; Michael Lassmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-30       Impact factor: 9.236

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.