Literature DB >> 26242410

The usefulness of the three-dimensional enhanced T1 high-resolution isotropic volume excitation MR in the evaluation of shoulder pathology: comparison with two-dimensional enhanced T1 fat saturation MR.

Hee J Park1, So Y Lee1, Myung H Rho1, Heon J Kwon1, Mi S Kim1, Eun C Chung1.   

Abstract

OBJECTIVE: To evaluate the diagnostic accuracy of three-dimensional (3D) enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) shoulder MR for variable shoulder pathology such as rotator cuff tear, labral injury and synovial pathology in comparison with two-dimensional enhanced fast spin echo T1 fat saturation (2D T1 FS) sequences MR.
METHODS: This retrospective study included 86 patients who underwent MRI of the shoulder using eTHRIVE technique. Two radiologists evaluated anatomic identification of the supraspinatus, glenoid labrum and acromioclavicular joint (AC joint) on routine MRI sequences (2D T1 FS) and compared them with the reformatted eTHRIVE images. Subjective scoring of the images was performed with a four-point scale that rated the degree of discrimination of the shape of the supraspinatus, glenoid labrum and AC joint. The diagnostic accuracy of eTHRIVE compared with routine MR images was evaluated in terms of rotator cuff pathology, labral pathology and synovial pathology.
RESULTS: Anatomic identification scores of the supraspinatus tendon and labrum were significantly lower for eTHRIVE than for 2D T1 FS. There were no significant differences between eTHRIVE and 2D T1 FS in anatomic identification of the AC joint. There were no significant differences between eTHRIVE and 2D T1 FS in diagnosing the three disease categories.
CONCLUSION: eTHRIVE had comparable diagnostic accuracy to 2D T1 FS imaging in the evaluation of rotator cuff tears, labral injury and synovial pathology, but anatomic identification was inferior to that of 2D T1 FS. ADVANCES IN KNOWLEDGE: The accuracy of 3D eTHRIVE imaging is comparable to that of 2D T1 FS for the diagnosis of rotator cuff tears, labral injury and synovial pathology.

Entities:  

Mesh:

Year:  2015        PMID: 26242410      PMCID: PMC4730961          DOI: 10.1259/bjr.20140830

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  13 in total

1.  Meniscal tear configurations: categorization with 3D isotropic turbo spin-echo MRI compared with conventional MRI at 3 T.

Authors:  Joon-Yong Jung; Won-Hee Jee; Michael Y Park; So-Yeon Lee; Jung-Man Kim
Journal:  AJR Am J Roentgenol       Date:  2012-02       Impact factor: 3.959

2.  Magnetic resonance colonography: comparison between T1 high-resolution isotropic volume excitation (THRIVE) and balanced fast field echo (bFFE) using an air enema or water-gadolinium enema.

Authors:  M S Kim; C S Park; E J Lee; M H Rho; N H Park; J H Joh; H J Park; J M Bae
Journal:  Clin Radiol       Date:  2010-04       Impact factor: 2.350

3.  Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction.

Authors:  Aiming Lu; Ethan Brodsky; Thomas M Grist; Walter F Block
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

4.  Understanding interobserver agreement: the kappa statistic.

Authors:  Anthony J Viera; Joanne M Garrett
Journal:  Fam Med       Date:  2005-05       Impact factor: 1.756

5.  3.0-T MRI of the supraspinatus tendon.

Authors:  Thomas Magee; David Williams
Journal:  AJR Am J Roentgenol       Date:  2006-10       Impact factor: 3.959

6.  Can isotropic fast gradient echo imaging be substituted for conventional T1 weighted sequences in shoulder MR arthrography at 3 Tesla?

Authors:  Thomas Magee
Journal:  J Magn Reson Imaging       Date:  2007-07       Impact factor: 4.813

7.  Multiplanar reconstruction in MR imaging of the knee. Comparison with standard sagittal and coronal images.

Authors:  S B Wieslander; E D Rappeport; G S Lausten; H S Thomsen
Journal:  Acta Radiol       Date:  1998-03       Impact factor: 1.990

8.  Intrinsic ligament and triangular fibrocartilage complex (TFCC) tears of the wrist: comparison of isovolumetric 3D-THRIVE sequence MR arthrography and conventional MR image at 3 T.

Authors:  Young Han Lee; Yun Rak Choi; Sungjun Kim; Ho-Taek Song; Jin-Suck Suh
Journal:  Magn Reson Imaging       Date:  2012-09-07       Impact factor: 2.546

Review 9.  Shoulder impingement syndrome.

Authors:  Michael C Koester; Michael S George; John E Kuhn
Journal:  Am J Med       Date:  2005-05       Impact factor: 4.965

10.  Diagnosis and management of adhesive capsulitis.

Authors:  Robert C Manske; Daniel Prohaska
Journal:  Curr Rev Musculoskelet Med       Date:  2008-12
View more
  4 in total

1.  Diagnostic performance of shoulder magnetic resonance arthrography for labral tears having surgery as reference: comparison of high-resolution isotropic 3D sequence (THRIVE) with standard protocol.

Authors:  Sun Hwa Lee; Seong Jong Yun; Youngno Yoon
Journal:  Radiol Med       Date:  2018-03-26       Impact factor: 3.469

2.  The radiomic-clinical model using the SHAP method for assessing the treatment response of whole-brain radiotherapy: a multicentric study.

Authors:  Yixin Wang; Jinwei Lang; Joey Zhaoyu Zuo; Yaqin Dong; Zongtao Hu; Xiuli Xu; Yongkang Zhang; Qinjie Wang; Lizhuang Yang; Stephen T C Wong; Hongzhi Wang; Hai Li
Journal:  Eur Radiol       Date:  2022-06-09       Impact factor: 5.315

Review 3.  Detecting Rotator Cuff Tears: A Network Meta-analysis of 144 Diagnostic Studies.

Authors:  Fanxiao Liu; Jinlei Dong; Wun-Jer Shen; Qinglin Kang; Dongsheng Zhou; Fei Xiong
Journal:  Orthop J Sports Med       Date:  2020-02-05

4.  Preoperative MRI Evaluation of Thyroid Cartilage Invasion in Patients with Laryngohypopharyngeal Cancer: Comparison of Contrast-Enhanced 2D Spin-Echo and 3D T1-Weighted Radial Gradient Recalled-Echo Techniques.

Authors:  C J Park; J-H Kim; S S Ahn; S-K Lee; Y W Koh; J Kim
Journal:  AJNR Am J Neuroradiol       Date:  2021-07-22       Impact factor: 4.966

  4 in total