Literature DB >> 15709136

Evaluation of MR imaging compatibility of a new intracranial pressure monitoring device.

Jens O Heidenreich1, Rüdiger Stendel, Mario Brock, Karl-Jürgen Wolf, Andreas M Schilling.   

Abstract

We report our observations on MR imaging quality and functionality of a recently introduced intracranial pressure monitoring device. The device was tested at two different field strengths in a pig brain specimen to investigate MR imaging artifacts, probe function during and after MR data acquisition, and device-related temperature changes in the brain tissue. Image reading was not impaired, and probe function, although reduced, was not fully interrupted during data acquisition.

Entities:  

Mesh:

Year:  2005        PMID: 15709136      PMCID: PMC7974080     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  12 in total

1.  [Systematics of imaging artifacts in MRT caused by metallic vascular implants (stents)].

Authors:  H Graf; T Klemm; U A Lauer; S Duda; C D Claussen; F Schick
Journal:  Rofo       Date:  2003-12

2.  Real-time-MR guidance for placement of a self-made fully MR-compatible atrial septal occluder: in vitro test.

Authors:  A Buecker; E Spuentrup; R Grabitz; F Freudenthal; T Schaeffter; J J van Vaals; W Günther
Journal:  Rofo       Date:  2002-03

Review 3.  The clinical efficacy of magnetic resonance imaging in neuroimaging.

Authors:  D L Kent; D R Haynor; W T Longstreth; E B Larson
Journal:  Ann Intern Med       Date:  1994-05-15       Impact factor: 25.391

4.  Traumatic brain injury and subarachnoid hemorrhage: in vivo occult pathology demonstrated by magnetic resonance spectroscopy may not be "ischaemic". A primary study and review of the literature.

Authors:  C S A Macmillan; J M Wild; J M Wardlaw; P J D Andrews; I Marshall; V J Easton
Journal:  Acta Neurochir (Wien)       Date:  2002-09       Impact factor: 2.216

Review 5.  Management of raised intracranial pressure.

Authors:  J D Pickard; M Czosnyka
Journal:  J Neurol Neurosurg Psychiatry       Date:  1993-08       Impact factor: 10.154

6.  Magnetic resonance imaging at 3.0 Tesla: challenges and advantages in clinical neurological imaging.

Authors:  Richard Frayne; Bradley G Goodyear; Peter Dickhoff; M Louis Lauzon; Robert J Sevick
Journal:  Invest Radiol       Date:  2003-07       Impact factor: 6.016

7.  Clinical evaluation of a new intracranial pressure monitoring device.

Authors:  R Stendel; J Heidenreich; A Schilling; R Akhavan-Sigari; R Kurth; T Picht; T Pietilä; O Suess; C Kern; J Meisel; M Brock
Journal:  Acta Neurochir (Wien)       Date:  2003-03       Impact factor: 2.216

Review 8.  Imaging of traumatic intracranial hemorrhage.

Authors:  Robert J Young; Sylvie Destian
Journal:  Neuroimaging Clin N Am       Date:  2002-05       Impact factor: 2.264

9.  Magnetic resonance imaging compatibility testing of intracranial pressure probes. Technical note.

Authors:  E J Williams; C S Bunch; T A Carpenter; S P Downey; I V Kendall; M Czosnyka; J D Pickard; J Martin; D K Menon
Journal:  J Neurosurg       Date:  1999-10       Impact factor: 5.115

10.  Continuous monitoring of cerebrovascular pressure reactivity allows determination of optimal cerebral perfusion pressure in patients with traumatic brain injury.

Authors:  Luzius A Steiner; Marek Czosnyka; Stefan K Piechnik; Piotr Smielewski; Doris Chatfield; David K Menon; John D Pickard
Journal:  Crit Care Med       Date:  2002-04       Impact factor: 7.598

View more