Literature DB >> 15700133

Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates.

R Abächerli1, C Pasquier, F Odille, M Kraemer, J-J Schmid, J Felblinger.   

Abstract

Electrocardiogram (ECG) acquisition is still a challenge as gradient artefacts superimposed on the electrophysiological signal can only be partially removed. The signal shape of theses artefacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false triggering/gating of the MRI. For their real-time suppression, an adaptive filter is proposed. The adaptive filter is based on the noise-canceller configuration with LMS coefficient updates. The references of the noise canceller are the three gradient signals that are acquired simultaneously with the noisy ECG. Tests were done on patients, on volunteers and using an MR-safe ECG simulator. The noise canceller's performance was measured offline, simulating real-time processing by point-by-point operations. To create worst-case scenarios, clinical sequences with strong- and fast-switching gradients have been chosen. The noise-cancelling filter reduces the gradient artefacts' peak amplitudes by 80-99% after adaptation, without changing the desired ECG signal shape. The estimated reduction of total average power of the MR gradient artefacts is 62-98%. The proposed filter is capable of reducing artefacts due to strong- and fast-switching gradients in real-time applications and worst-case situations. The quality of the ECG is sufficiently high that a standard one-lead QRS-detector can be used for gating/triggering the MRI. For permanent patient monitoring, further improvements are needed.

Entities:  

Mesh:

Year:  2005        PMID: 15700133     DOI: 10.1007/s10334-004-0093-1

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  13 in total

1.  Restoration of MR-induced artifacts in simultaneously recorded MR/EEG data.

Authors:  J Sijbers; I Michiels; M Verhoye; J Van Audekerke; A Van der Linden; D Van Dyck
Journal:  Magn Reson Imaging       Date:  1999-11       Impact factor: 2.546

2.  Cardiac-respiratory gating method for magnetic resonance imaging of the heart.

Authors:  Q Yuan; L Axel; E H Hernandez; L Dougherty; J J Pilla; C H Scott; V A Ferrari; A S Blom
Journal:  Magn Reson Med       Date:  2000-02       Impact factor: 4.668

3.  Acquiring simultaneous EEG and functional MRI.

Authors:  R I Goldman; J M Stern; J Engel; M S Cohen
Journal:  Clin Neurophysiol       Date:  2000-11       Impact factor: 3.708

4.  A method for removing imaging artifact from continuous EEG recorded during functional MRI.

Authors:  P J Allen; O Josephs; R Turner
Journal:  Neuroimage       Date:  2000-08       Impact factor: 6.556

5.  Influence of magnetically-induced E-fields on cardiac electric activity during MRI: A modeling study.

Authors:  Feng Liu; Ling Xia; Stuart Crozier
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

6.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

7.  Magnetohydrodynamics of blood flow.

Authors:  J R Keltner; M S Roos; P R Brakeman; T F Budinger
Journal:  Magn Reson Med       Date:  1990-10       Impact factor: 4.668

8.  Burns associated with the use of monitoring equipment during MR procedures.

Authors:  F G Shellock; E Kanal
Journal:  J Magn Reson Imaging       Date:  1996 Jan-Feb       Impact factor: 4.813

9.  Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering.

Authors:  J Felblinger; C Lehmann; C Boesch
Journal:  Magn Reson Med       Date:  1994-10       Impact factor: 4.668

10.  Hazardous situation in the MR bore: induction in ECG leads causes fire.

Authors:  Harald Kugel; Christoph Bremer; Marco Püschel; Roman Fischbach; Horst Lenzen; Bernd Tombach; Hugo Van Aken; Walter Heindel
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

View more
  9 in total

1.  Adaptive removal of gradients-induced artefacts on ECG in MRI: a performance analysis of RLS filtering.

Authors:  Mario Sansone; Luciano Mirarchi; Marcello Bracale
Journal:  Med Biol Eng Comput       Date:  2010-03-18       Impact factor: 2.602

2.  Integrating fMRI with psychophysiological measurements in the study of decision-making.

Authors:  Savio W H Wong; Gui Xue; Antoine Bechara
Journal:  J Neurosci Psychol Econ       Date:  2011

3.  3DQRS: a method to obtain reliable QRS complex detection within high field MRI using 12-lead electrocardiogram traces.

Authors:  T Stan Gregory; Ehud J Schmidt; Shelley Hualei Zhang; Zion Tsz Ho Tse
Journal:  Magn Reson Med       Date:  2014-01-22       Impact factor: 4.668

4.  Adaptive step size LMS improves ECG detection during MRI at 1.5 and 3 T.

Authors:  André Guillou; Jean-Marc Sellal; Sarah Ménétré; Grégory Petitmangin; Jacques Felblinger; Laurent Bonnemains
Journal:  MAGMA       Date:  2017-06-19       Impact factor: 2.310

5.  Gradient-induced voltages on 12-lead ECGs during high duty-cycle MRI sequences and a method for their removal considering linear and concomitant gradient terms.

Authors:  Shelley HuaLei Zhang; Zion Tsz Ho Tse; Charles L Dumoulin; Raymond Y Kwong; William G Stevenson; Ronald Watkins; Jay Ward; Wei Wang; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2015-06-23       Impact factor: 4.668

6.  Continuous Rapid Quantification of Stroke Volume Using Magnetohydrodynamic Voltages in 3T Magnetic Resonance Imaging.

Authors:  T Stan Gregory; John Oshinski; Ehud J Schmidt; Raymond Y Kwong; William G Stevenson; Zion Tsz Ho Tse
Journal:  Circ Cardiovasc Imaging       Date:  2015-12       Impact factor: 7.792

7.  Adaptive noise cancellation to suppress electrocardiography artifacts during real-time interventional MRI.

Authors:  Vincent Wu; Israel M Barbash; Kanishka Ratnayaka; Christina E Saikus; Merdim Sonmez; Ozgur Kocaturk; Robert J Lederman; Anthony Z Faranesh
Journal:  J Magn Reson Imaging       Date:  2011-05       Impact factor: 4.813

8.  A 1.5T MRI-conditional 12-lead electrocardiogram for MRI and intra-MR intervention.

Authors:  Zion Tsz Ho Tse; Charles L Dumoulin; Gari D Clifford; Jeff Schweitzer; Lei Qin; Julien Oster; Michael Jerosch-Herold; Raymond Y Kwong; Gregory Michaud; William G Stevenson; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

Review 9.  Electrophysiological Measurement of Emotion and Somatic State Affecting Ambiguity Decision: Evidences From SCRs, ERPs, and HR.

Authors:  Fuming Xu; Long Huang
Journal:  Front Psychol       Date:  2020-05-14
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.