Literature DB >> 12571203

Performance of OSEM and depth-dependent resolution recovery algorithms for the evaluation of global left ventricular function in 201Tl gated myocardial perfusion SPECT.

Doumit Daou1, Isabelle Pointurier, Carlos Coaguila, Didier Vilain, Abdel Wahab Benada, Rachida Lebtahi, Thierry Fourme, Michel Slama, Dominique Le Guludec.   

Abstract

UNLABELLED: It is unknown whether the use of ordered-subsets expectation maximization (OSEM) and depth-dependent resolution recovery (RR) will increase the accuracy of (201)Tl electrocardiogram-gated SPECT (GSPECT) for the measurement of global left ventricular (LV) function.
METHODS: Fifty-six patients having both rest (201)Tl GSPECT and planar equilibrium radionuclide angiography (planar(RNA)) on the same day were studied. Twenty-nine patients also had LV conventional contrast angiography (Rx). LV ejection fraction (LVEF), end-diastolic volume (EDV), and end-systolic volume (ESV) were calculated with the quantitative gated SPECT software (QGS) using 4 different processing methods: filtered backprojection (FBP), OSEM, RR + FBP, and RR + OSEM. LVEF calculated with planar(RNA) and LV EDV and ESV calculated with Rx were considered gold standards. LVEF and volumes provided with the GSPECT methods were compared with the gold standard methods.
RESULTS: LVEF calculated with GSPECT methods (FBP, OSEM, RR + FBP, and RR + OSEM) were similar (not statistically significant) and correlated well with planar(RNA). On Bland-Altman analysis, the mean +/- SD of absolute difference in LVEF with GSPECT FBP, OSEM, RR + FBP, and RR + OSEM methods versus planar(RNA) were similar, with relatively large limits of agreement. LV volumes calculated with the 4 GSPECT methods were significantly lower but correlated well with Rx LV volumes. LV volumes calculated with FBP and OSEM were lower than those calculated with RR + FBP and RR + OSEM (P < 0.01). On Bland-Altman analysis, the mean +/- SD of absolute difference in LV volumes with FBP, OSEM, RR + FBP, and RR + OSEM versus Rx was, respectively, 56 +/- 45 mL (P < 0.01 vs. the other 3 methods), 57 +/- 45 mL (P < 0.01 vs. the other 3 methods), 43 +/- 48 mL, and 46 +/- 47 mL, with correspondingly large limits of agreement. The variance of random error did not differ between FBP, OSEM, RR + FBP, and RR + OSEM for either LVEF or volumes.
CONCLUSION: OSEM and FBP presented similar accuracy for LVEF and volume measured with the QGS software. Their combination with depth-dependent RR provided similar LVEF but more accurate LV volumes.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12571203

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  11 in total

1.  Recommendations for reducing radiation exposure in myocardial perfusion imaging.

Authors:  Manuel D Cerqueira; Kevin C Allman; Edward P Ficaro; Christopher L Hansen; Kenneth J Nichols; Randall C Thompson; William A Van Decker; Marko Yakovlevitch
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

2.  Single photon-emission computed tomography.

Authors:  Thomas A Holly; Brian G Abbott; Mouaz Al-Mallah; Dennis A Calnon; Mylan C Cohen; Frank P DiFilippo; Edward P Ficaro; Michael R Freeman; Robert C Hendel; Diwakar Jain; Scott M Leonard; Kenneth J Nichols; Donna M Polk; Prem Soman
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

3.  Prospects for advancing nuclear cardiology by means of new detector designs.

Authors:  Kenneth J Nichols; Andrew Van Tosh; Christopher J Palestro
Journal:  J Nucl Cardiol       Date:  2009-07-24       Impact factor: 5.952

4.  New reconstruction algorithm allows shortened acquisition time for myocardial perfusion SPECT.

Authors:  Ines Valenta; Valerie Treyer; Lars Husmann; Oliver Gaemperli; Michael J Schindler; Bernhard A Herzog; Patrick Veit-Heibach; Ronny R Buechel; René Nkoulou; Aju P Pazhenkottil; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-11-18       Impact factor: 9.236

5.  Effect of reconstruction algorithms on the accuracy of (99m)Tc sestamibi SPECT/CT parathyroid imaging.

Authors:  Kenneth J Nichols; Gene G Tronco; Christopher J Palestro
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-01-15

6.  Attenuation correction of (111)In planar images by use of dual energy, fundamental study by Monte Carlo simulation.

Authors:  Seiji Shirakawa; Masanori Tadokoro; Hiroshi Hashimoto; Tomoya Ushiroda; Hiroshi Toyama
Journal:  Radiol Phys Technol       Date:  2014-08-23

7.  Quantification of the myocardial area at risk using coronary CT angiography and Voronoi algorithm-based myocardial segmentation.

Authors:  Akira Kurata; Atsushi Kono; Tsuyoshi Sakamoto; Teruhito Kido; Teruhito Mochizuki; Hiroshi Higashino; Mitsunori Abe; Adriaan Coenen; Raluca G Saru-Chelu; Pim J de Feyter; Gabriel P Krestin; Koen Nieman
Journal:  Eur Radiol       Date:  2014-08-31       Impact factor: 5.315

8.  New method for accurate estimations of LV function for small hearts.

Authors:  Keiichiro Magota; Nagara Tamaki
Journal:  J Nucl Cardiol       Date:  2016-06-01       Impact factor: 5.952

9.  Monte Carlo simulation of the acquisition conditions for 177Lu molecular imaging of hepatic tumors.

Authors:  Yuya Sekikawa; Keita Funada; Go Akamatsu; Kazuhiko Himuro; Akihiko Takahashi; Shingo Baba; Masayuki Sasaki
Journal:  Ann Nucl Med       Date:  2021-05-31       Impact factor: 2.668

10.  Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging.

Authors:  Lotte H Enevoldsen; Changez A K Menashi; Ulrik B Andersen; Lars T Jensen; Otto M Henriksen
Journal:  J Nucl Cardiol       Date:  2013-08-21       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.