Literature DB >> 2243988

Determination of left ventricular volume and mass with use of biphasic spin-echo MR imaging: comparison with cine MR.

G R Caputo1, J Suzuki, C Kondo, H Cho, R A Quaife, C B Higgins, D L Parker.   

Abstract

In this study, the authors compared a new rapid spin-echo magnetic resonance (MR) imaging method, biphasic MR, with cine MR in the determination of left ventricular volume and mass in healthy volunteers. Biphasic spin-echo MR images covering the entire heart were obtained with use of the electrocardiogram R wave and the downslope of the T wave at both end diastole and end systole, respectively. Biphasic MR-determined values correlated well with small standard errors of the estimate (end-diastolic volume = 7.82 cm3, end-diastolic mass = 10.20 g, end-systolic mass = 10.08 g, ejection fraction = 2.62%) and were more reproducible. Cine MR-defined end-systolic volume was significantly larger (P less than .01) and ejection fraction was significantly smaller (P less than .005) than biphasic MR-determined values probably because of the uncertainty in isolating end systole with cine MR. Left ventricular volumes, mass, and ejection fraction are more accurately and reproducibly quantified in a more time-efficient manner with use of biphasic MR than with cine MR because of its significantly shorter image acquisition and reconstruction times.

Entities:  

Mesh:

Year:  1990        PMID: 2243988     DOI: 10.1148/radiology.177.3.2243988

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  [Cardiac functional analysis with MRI].

Authors:  T A Sandner; D Theisen; K U Bauner; M Picciolo; M F Reiser; B J Wintersperger
Journal:  Radiologe       Date:  2010-06       Impact factor: 0.635

Review 2.  Magnetic resonance imaging in congenital heart disease in children.

Authors:  A E Schlesinger; R J Hernandez
Journal:  Tex Heart Inst J       Date:  1996

Review 3.  Evaluation of left ventricular function using cardiac magnetic resonance imaging.

Authors:  Suchi Grover; Darryl P Leong; Joseph B Selvanayagam
Journal:  J Nucl Cardiol       Date:  2011-04       Impact factor: 5.952

4.  Left ventricular quantification with breath-hold MR imaging: comparison with echocardiography.

Authors:  J G Bogaert; H T Bosmans; F E Rademakers; E P Bellon; M C Herregods; J A Verschakelen; F Van de Werf; G J Marchal
Journal:  MAGMA       Date:  1995-03       Impact factor: 2.310

5.  Gated SPECT assessment of left ventricular function is sensitive to small patient motions and to low rates of triggering errors: a comparison with equilibrium radionuclide angiography.

Authors:  Wassila Djaballah; Marc A Muller; Anne C Bertrand; Pierre Y Marie; Bernard Chalon; Karim Djaballah; Pierre Olivier; Andreï Codreanu; Gilles Karcher; Alain Bertrand
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

Review 6.  Magnetic resonance imaging of acquired cardiac disease.

Authors:  C L Carrol; C B Higgins; G R Caputo
Journal:  Tex Heart Inst J       Date:  1996

7.  Measurements of left ventricular dimensions using real-time acquisition in cardiac magnetic resonance imaging: comparison with conventional gradient echo imaging.

Authors:  S Plein; W H Smith; J P Ridgway; A Kassner; D J Beacock; T N Bloomer; M U Sivananthan
Journal:  MAGMA       Date:  2001-10       Impact factor: 2.533

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.