Comparison of ERGs recorded with skin and corneal-contact electrodes in normal children and adults.

Keith Bradshaw1, Ronald Hansen, Anne Fulton.   

Abstract

PURPOSE: Compare electroretinogram (ERG) responses to full-field stimuli recorded with corneal-contact and skin electrodes in healthy children and adults.
METHOD: ERGs were recorded independently in two laboratories in children (aged 4-14 years) and adults (aged 20-62 years). A Burian-Allen (BA) electrode were used to test both children and adults in one laboratory. A Gold Foil (GF) electrode was used to test adults and skin electrodes to test children and adults in the other laboratory. Responses were recorded to full-field stimuli similar to those specified in the ISCEV Standard. Dark-adapted responses were also recorded over a 5 log unit range of stimulus energies.
RESULTS: All ISCEV rod and cone responses were recorded in every subject with skin electrodes as well as with eye-contact electrodes. BA and GF amplitudes and latencies were similar for the majority of ISCEV responses. The waveform morphology of rod and cone skin electrode responses was similar to corneal electrode responses in children and adults. GF electrode responses were on average 4 to 5 times larger than skin electrode responses recorded in the same laboratory. After scaling skin electrode responses by 4.5 the distribution of response amplitudes was found to be similar to that for the eye-contact electrodes in both children and adults. Dark-adapted responses were recorded to all stimulus intensities in every subject with each type of electrode. B-wave S-R functions were evaluated by fitting the Naka-Rushton equation. Vmax was similar for BA and GF electrode responses and this was about 4 times greater than for skin electrode responses. Log (sigma) was similar for GF and skin electrodes but these differed significantly from the BA electrode. Vmax and log(sigma) were similar in adults and children for BA and skin electrode responses.
CONCLUSION: ERGs to full-field stimuli can be recorded successfully with either eye-contact or skin electrodes.

Entities:  

Mesh:

Year:  2004        PMID: 15675199     DOI: 10.1007/s10633-004-1751-3

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  21 in total

1.  Dark-adapted luminance-response functions with skin and corneal electrodes.

Authors:  N Wali; L E Leguire
Journal:  Doc Ophthalmol       Date:  1991       Impact factor: 2.379

2.  Effect of scleral recording location on ERG amplitude.

Authors:  S J Cringle; V A Alder; M J Brown; D Y Yu
Journal:  Curr Eye Res       Date:  1986-12       Impact factor: 2.424

3.  Amplitude scaling relationships of Burian-Allen, gold foil and Dawson, Trick and Litzkow electrodes.

Authors:  M P Hennessy
Journal:  Doc Ophthalmol       Date:  1995       Impact factor: 2.379

4.  Electroretinography with noncorneal and corneal electrodes.

Authors:  J F Giltrow-Tyler; S J Crews; N Drasdo
Journal:  Invest Ophthalmol Vis Sci       Date:  1978-11       Impact factor: 4.799

Review 5.  Electrophysiologic testing techniques for children.

Authors:  A B Fulton; E E Hartmann; R M Hansen
Journal:  Doc Ophthalmol       Date:  1989-04       Impact factor: 2.379

6.  Diagnosing children presenting with asymmetric pendular nystagmus.

Authors:  F S Shaw; A Kriss; I Russel-Eggitt; D Taylor; C Harris
Journal:  Dev Med Child Neurol       Date:  2001-09       Impact factor: 5.449

Review 7.  Electrophysiological assessment of visual pathway function in infants.

Authors:  A Kriss; I Russell-Eggitt
Journal:  Eye (Lond)       Date:  1992       Impact factor: 3.775

8.  Development of electroretinogram and rod phototransduction response in human infants.

Authors:  M E Breton; G E Quinn; A W Schueller
Journal:  Invest Ophthalmol Vis Sci       Date:  1995-07       Impact factor: 4.799

9.  Electroretinography: application to clinical studies of infants.

Authors:  A B Fulton; R M Hansen
Journal:  J Pediatr Ophthalmol Strabismus       Date:  1985 Nov-Dec       Impact factor: 1.402

View more
  17 in total

1.  The pattern electroretinogram as a tool to monitor progressive retinal ganglion cell dysfunction in the DBA/2J mouse model of glaucoma.

Authors:  Vittorio Porciatti; Maher Saleh; Mahesh Nagaraju
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-02       Impact factor: 4.799

2.  Long-term effects of retinopathy of prematurity (ROP) on rod and rod-driven function.

Authors:  Maureen E Harris; Anne Moskowitz; Anne B Fulton; Ronald M Hansen
Journal:  Doc Ophthalmol       Date:  2010-11-03       Impact factor: 2.379

3.  Pattern electroretinogram to detect glaucoma: comparing the PERGLA and the PERG Ratio protocols.

Authors:  Michael Bach; Anke Ramharter-Sereinig
Journal:  Doc Ophthalmol       Date:  2013-10-15       Impact factor: 2.379

4.  The relationship between stimulus intensity and response amplitude for the photopic negative response of the flash electroretinogram.

Authors:  A M Binns; K E Mortlock; R V North
Journal:  Doc Ophthalmol       Date:  2011-01-18       Impact factor: 2.379

5.  Early postoperative evaluation of retinal function by electroretinography after vitreous surgery for idiopathic epimacular membrane.

Authors:  Akira Watanabe; Tamaki Gekka; Kota Arai; K Kohzaki; Hiroshi Tsuneoka
Journal:  Doc Ophthalmol       Date:  2017-03-18       Impact factor: 2.379

6.  ISCEV extended protocol for the stimulus-response series for the dark-adapted full-field ERG b-wave.

Authors:  Mary A Johnson; Brett G Jeffrey; André M V Messias; Anthony G Robson
Journal:  Doc Ophthalmol       Date:  2019-03-30       Impact factor: 2.379

7.  Full-field ERG responses recorded with skin electrodes in paediatric patients with retinal dystrophy.

Authors:  S P Meredith; M A Reddy; L E Allen; A T Moore; K Bradshaw
Journal:  Doc Ophthalmol       Date:  2004-07       Impact factor: 2.379

8.  Pediatric clinical visual electrophysiology: a survey of actual practice.

Authors:  Anne B Fulton; Jelka Brecelj; Birgit Lorenz; Anne Moskowitz; Dorothy Thompson; Carol A Westall
Journal:  Doc Ophthalmol       Date:  2006-11-16       Impact factor: 2.379

9.  Evaluation of light- and dark-adapted ERGs using a mydriasis-free, portable system: clinical classifications and normative data.

Authors:  Henry Liu; Xiang Ji; Sabrina Dhaliwal; Syeda Naima Rahman; Michelle McFarlane; Anupreet Tumber; Jeff Locke; Tom Wright; Ajoy Vincent; Carol Westall
Journal:  Doc Ophthalmol       Date:  2018-10-24       Impact factor: 2.379

10.  Flash electroretinography: normative values with surface skin electrodes and no pupil dilation using a standard stimulation protocol.

Authors:  Eleftherios S Papathanasiou; Savvas S Papacostas
Journal:  Doc Ophthalmol       Date:  2007-07-04       Impact factor: 2.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.