Literature DB >> 15664577

Effect of reduction in tube current on reader confidence in paediatric computed tomography.

R Shah1, A K Gupta, M M Rehani, A K Pandey, S Mukhopadhyay.   

Abstract

BACKGROUND: Computed tomography (CT) contributes significantly to the total radiation dose derived from medical imaging in children. As the number of CT examinations increases there is renewed interest in possible ways to minimize such radiation. AIM: To study the effect of decremental reduction in tube current settings on structural resolution and on reader confidence in being able to reach a final diagnosis.
MATERIALS AND METHODS: The study involved spiral CT of children aged 0-13 years. CT performed at reduced mA settings (60-75, 76-90 and 91-130 mA for thoracic, abdominal and pelvic examinations, and 76-90 and 91-130 mA for cranial examinations) were compared with similar investigations at conventional settings (180-240 mA). Images were scored by two blinded readers for structural resolution and diagnostic confidence. Structural resolution was scored on a binary (adequate or not) scale for six structures each in cranial, thoracic and pelvic examinations and for eight structures in abdominal studies, and reader confidence was scored on a four-point scale as 25-100%. Scores from the two readers were averaged for comparison in subgroup analyses.
RESULTS: Reduction of tube current settings to 75-90 mA for thoracic, abdominal and pelvic examinations and to 90-130 mA for cranial examinations was not associated with any significant deterioration in image quality. The number of scans considered satisfactory were comparable even at 60-75 mA, although the total relative scores for structural resolution at this setting were lower.
CONCLUSION: Tube current settings can be significantly reduced in all paediatric age groups, in all regions. In younger children the impact of such reduction in tube current is likely to be greater. Cranial scans are more sensitive to such reductions as compared to thoracic or abdominopelvic examinations.

Entities:  

Mesh:

Year:  2005        PMID: 15664577     DOI: 10.1016/j.crad.2004.08.011

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  8 in total

1.  Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom.

Authors:  A D Goren; R D Prins; L T Dauer; B Quinn; A Al-Najjar; R D Faber; G Patchell; I Branets; D C Colosi
Journal:  Dentomaxillofac Radiol       Date:  2013-02-14       Impact factor: 2.419

2.  Can a revised paediatric radiation dose reduction CT protocol be applied and still maintain anatomical delineation, diagnostic confidence and overall imaging quality?

Authors:  S Kritsaneepaiboon; P Siriwanarangsun; P Tanaanantarak; A Krisanachinda
Journal:  Br J Radiol       Date:  2014-06-24       Impact factor: 3.039

3.  Multicentric study of patients receiving 50 or 100 mSv in a single day through CT imaging-frequency determination and imaging protocols involved.

Authors:  Madan M Rehani; John Heil; Vinit Baliyan
Journal:  Eur Radiol       Date:  2021-03-08       Impact factor: 5.315

4.  Neonatal Intracranial Ischemia and Hemorrhage : Role of Cranial Sonography and CT Scanning.

Authors:  Imran Ahmad Khan; Shagufta Wahab; Rizwan Ahmad Khan; Ekram Ullah; Manazir Ali
Journal:  J Korean Neurosurg Soc       Date:  2010-02-28

5.  Reducing radiation exposure from computed tomography of the brain in children--report of a practical approach.

Authors:  Sui-To Wong; Gwendolin Yiu; Yiu-Man Poon; Ming-Keung Yuen; Dawson Fong
Journal:  Childs Nerv Syst       Date:  2012-01-12       Impact factor: 1.475

6.  Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction.

Authors:  Maria Raissaki; Kostas Perisinakis; John Damilakis; Nicholas Gourtsoyiannis
Journal:  Pediatr Radiol       Date:  2010-06-16

Review 7.  Multidetector CT in children: current concepts and dose reduction strategies.

Authors:  Rutger A J Nievelstein; Ingrid M van Dam; Aart J van der Molen
Journal:  Pediatr Radiol       Date:  2010-06-10

8.  Multislice CT of the head and body routine scans: Are scanning protocols adjusted for paediatric patients?

Authors:  Z Sun; Ks Al Ghamdi; Ih Baroum
Journal:  Biomed Imaging Interv J       Date:  2012-01-01
  8 in total