Literature DB >> 15644089

Pancreatic polypeptide administration reduces insulin requirements of artificial pancreas in pancreatectomized dogs.

Tetsuya Kono1, Kazuhiro Hanazaki, Kazuyuki Yazawa, Satoshi Ashizawa, William E Fisher, Xiao-Ping Wang, Yukihiko Nosé, F Charles Brunicardi.   

Abstract

An artificial endocrine pancreas is a mechanical device that frequently measures blood glucose and adjusts the rate of insulin infusion to maintain normoglycemia. In this study, we evaluated the effect of pancreatic polypeptide (PP) on insulin requirements after total pancreatectomy. However, other endocrine hormones are needed not only to facilitate the effect of insulin, but also to regulate insulin functions in vivo. In this study, the effect of PP infusion on insulin requirements after total pancreatectomy in dogs is examined. After total pancreatectomy, five dogs were supported by artificial endocrine pancreas model STG-22 for 72 h. In a second group of five dogs, both insulin and PP were infused. Mean blood glucose levels and insulin requirements were compared between the two groups. There was no difference in mean plasma glucose levels between the two groups. In all 10 dogs, the mean blood glucose level for 72 h was 110 +/- 4 mg/dL and was tightly controlled between 65 and 190 mg/dL. However, the insulin requirement for the first and second postoperative days in the group treated with PP was significantly less than that of the control group (90.0 +/- 20.8 mU/kg vs. 445.0 +/- 151.9 mU/kg; P < 0.05, and 562.7 +/- 126.5 mU/kg vs. 1007.7 +/- 144.9 mU/kg; P < 0.05, respectively). We conclude that infusion of PP reduces the insulin requirement for the initial 48 h in pancreatectomized dogs treated with an artificial endocrine pancreas.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15644089     DOI: 10.1111/j.1525-1594.2004.29008.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  14 in total

1.  Evaluation of artificial pancreas technology for continuous blood glucose monitoring in dogs.

Authors:  Akihiro Mori; Peter Lee; Takeshi Yokoyama; Hitomi Oda; Kaori Saeki; Yohei Miki; Satoshi Nozawa; Daigo Azakami; Yutaka Momota; Yuki Makino; Takako Matsubara; Motohisa Osaka; Katsumi Ishioka; Toshiro Arai; Toshinori Sako
Journal:  J Artif Organs       Date:  2011-04-14       Impact factor: 1.731

Review 2.  Tight perioperative glycemic control using an artificial endocrine pancreas.

Authors:  Kazuhiro Hanazaki; Hiromichi Maeda; Takehiro Okabayashi
Journal:  Surg Today       Date:  2009-12-29       Impact factor: 2.549

Review 3.  Tight glycemic control using an artificial endocrine pancreas may play an important role in preventing infection after pancreatic resection.

Authors:  Kazuhiro Hanazaki
Journal:  World J Gastroenterol       Date:  2012-08-07       Impact factor: 5.742

4.  Technical challenges and clinical outcomes of using a closed-loop glycemic control system in the hospital.

Authors:  Takehiro Okabayashi; Akihito Kozuki; Tatsuaki Sumiyoshi; Yasuo Shima
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

Review 5.  Current status and issues of the artificial pancreas: abridged English translation of a special issue in Japanese.

Authors:  Tsutomu Namikawa; Masaya Munekage; Tomoaki Yatabe; Hiroyuki Kitagawa; Kazuhiro Hanazaki
Journal:  J Artif Organs       Date:  2018-01-22       Impact factor: 1.731

Review 6.  Surgery for a gastroenteropancreatic neuroendocrine tumor (GEPNET) in multiple endocrine neoplasia type 1.

Authors:  Kazuhiro Hanazaki; Akihiro Sakurai; Masaya Munekage; Kengo Ichikawa; Tsutomu Namikawa; Takehiro Okabayashi; Masayuki Imamura
Journal:  Surg Today       Date:  2012-10-19       Impact factor: 2.549

7.  An artificial pancreas provided a novel model of blood glucose level variability in beagles.

Authors:  Masaya Munekage; Tomoaki Yatabe; Hiroyuki Kitagawa; Yuka Takezaki; Takahiko Tamura; Tsutomu Namikawa; Kazuhiro Hanazaki
Journal:  J Artif Organs       Date:  2015-08-08       Impact factor: 1.731

Review 8.  Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

Authors:  Kazuhiro Hanazaki; Masaya Munekage; Hiroyuki Kitagawa; Tomoaki Yatabe; Eri Munekage; Mai Shiga; Hiromichi Maeda; Tsutomu Namikawa
Journal:  J Artif Organs       Date:  2016-05-03       Impact factor: 1.731

9.  Continuous post-operative blood glucose monitoring and control using a closed-loop system in patients undergoing hepatic resection.

Authors:  Takehiro Okabayashi; Kazuhiro Hnazaki; Isao Nishimori; Takeki Sugimoto; Hiromichi Maeda; Tomoaki Yatabe; Ken Dabanaka; Michiya Kobayashi; Koichi Yamashita
Journal:  Dig Dis Sci       Date:  2007-10-13       Impact factor: 3.199

Review 10.  Problems associated with glucose toxicity: role of hyperglycemia-induced oxidative stress.

Authors:  Shinji Kawahito; Hiroshi Kitahata; Shuzo Oshita
Journal:  World J Gastroenterol       Date:  2009-09-07       Impact factor: 5.742

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.