Literature DB >> 27142278

Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

Kazuhiro Hanazaki1, Masaya Munekage1, Hiroyuki Kitagawa1, Tomoaki Yatabe2, Eri Munekage1, Mai Shiga1, Hiromichi Maeda1, Tsutomu Namikawa3.   

Abstract

The incidence of diabetes is increasing at an unprecedented pace and has become a serious health concern worldwide during the last two decades. Despite this, adequate glycemic control using an artificial pancreas has not been established, although the 21st century has seen rapid developments in this area. Herein, we review current topics in glycemic control for both the wearable artificial pancreas for type 1 and type 2 diabetic patients and the bedside artificial pancreas for surgical diabetic patients. In type 1 diabetic patients, nocturnal hypoglycemia associated with insulin therapy remains a serious problem that could be addressed by the recent development of a wearable artificial pancreas. This smart phone-like device, comprising a real-time, continuous glucose monitoring system and insulin pump system, could potentially significantly reduce nocturnal hypoglycemia compared with conventional glycemic control. Of particular interest in this space are the recent inventions of a low-glucose suspend feature in the portable systems that automatically stops insulin delivery 2 h following a glucose sensor value <70 mg/dL and a bio-hormonal pump system consisting of insulin and glucagon pumps. Perioperative tight glycemic control using a bedside artificial pancreas with the closed-loop system has also proved safe and effective for not only avoiding hypoglycemia, but also for reducing blood glucose level variability resulting in good surgical outcomes. We hope that a more sophisticated artificial pancreas with closed-loop system will now be taken up for routine use worldwide, providing enormous relief for patients suffering from uncontrolled hyperglycemia, hypoglycemia, and/or variability in blood glucose concentrations.

Entities:  

Keywords:  Artificial pancreas; Glycemic control; Hypoglycemia; Surgical stress-induced hyperglycemia; Type 1 diabetes

Mesh:

Substances:

Year:  2016        PMID: 27142278     DOI: 10.1007/s10047-016-0904-y

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  61 in total

1.  Correlation between hyperglycemia and mortality in a medical and surgical intensive care unit.

Authors:  V Gabbanelli; S Pantanetti; A Donati; T Principi; P Pelaia
Journal:  Minerva Anestesiol       Date:  2005-11       Impact factor: 3.051

Review 2.  Progressive artificial endocrine pancreas: The era of novel perioperative blood glucose control for surgery.

Authors:  Yuuki Tsukamoto; Takehiro Okabayashi; Kazuhiro Hanazaki
Journal:  Surg Today       Date:  2011-09-16       Impact factor: 2.549

Review 3.  Artificial organs 2014: a year in review.

Authors:  Paul S Malchesky
Journal:  Artif Organs       Date:  2015-03       Impact factor: 3.094

4.  Evaluation of a novel artificial pancreas: closed loop glycemic control system with continuous blood glucose monitoring.

Authors:  Yuuki Tsukamoto; Yoshihiko Kinoshita; Hiroyuki Kitagawa; Masaya Munekage; Eri Munekage; Yuka Takezaki; Tomoaki Yatabe; Koichi Yamashita; Rie Yamazaki; Takehiro Okabayashi; Masatoshi Tarumi; Masaki Kobayashi; Suguru Mishina; Kazuhiro Hanazaki
Journal:  Artif Organs       Date:  2013-03-18       Impact factor: 3.094

5.  Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial.

Authors:  Ahmad Haidar; Laurent Legault; Virginie Messier; Tina Maria Mitre; Catherine Leroux; Rémi Rabasa-Lhoret
Journal:  Lancet Diabetes Endocrinol       Date:  2014-11-27       Impact factor: 32.069

Review 6.  Continuous subcutaneous insulin infusion versus multiple daily insulin injections in patients with diabetes mellitus: systematic review and meta-analysis.

Authors:  K Jeitler; K Horvath; A Berghold; T W Gratzer; K Neeser; T R Pieber; A Siebenhofer
Journal:  Diabetologia       Date:  2008-03-20       Impact factor: 10.122

7.  Nocturnal hypoglycaemias in type 1 diabetic patients: what can we learn with continuous glucose monitoring?

Authors:  L Guillod; S Comte-Perret; D Monbaron; R C Gaillard; J Ruiz
Journal:  Diabetes Metab       Date:  2007-07-24       Impact factor: 6.041

8.  Benefits and risks of tight glucose control in critically ill adults: a meta-analysis.

Authors:  Renda Soylemez Wiener; Daniel C Wiener; Robin J Larson
Journal:  JAMA       Date:  2008-08-27       Impact factor: 56.272

9.  Threshold-based insulin-pump interruption for reduction of hypoglycemia.

Authors:  Richard M Bergenstal; David C Klonoff; Satish K Garg; Bruce W Bode; Melissa Meredith; Robert H Slover; Andrew J Ahmann; John B Welsh; Scott W Lee; Francine R Kaufman
Journal:  N Engl J Med       Date:  2013-06-22       Impact factor: 91.245

10.  Glucose variability is associated with intensive care unit mortality.

Authors:  Jeroen Hermanides; Titia M Vriesendorp; Robert J Bosman; Durk F Zandstra; Joost B Hoekstra; J Hans Devries
Journal:  Crit Care Med       Date:  2010-03       Impact factor: 7.598

View more
  9 in total

1.  Optogenerapy: When bio-electronic implant enters the modern syringe era.

Authors:  Fanny Michel; Marc Folcher
Journal:  Porto Biomed J       Date:  2017-07-29

2.  Translational Research Symposium-collaborative efforts as driving forces of healthcare innovation.

Authors:  João Q Coentro; Andrea De Pieri; Diana Gaspar; Dimitrios Tsiapalis; Dimitrios I Zeugolis; Yves Bayon
Journal:  J Mater Sci Mater Med       Date:  2019-12-02       Impact factor: 3.896

Review 3.  Current status and issues of the artificial pancreas: abridged English translation of a special issue in Japanese.

Authors:  Tsutomu Namikawa; Masaya Munekage; Tomoaki Yatabe; Hiroyuki Kitagawa; Kazuhiro Hanazaki
Journal:  J Artif Organs       Date:  2018-01-22       Impact factor: 1.731

4.  Impact of using a perioperative artificial endocrine pancreas in pancreatic resection.

Authors:  Toshiaki Yoshimoto; Tetsuya Ikemoto; Yuji Morine; Satoru Imura; Yu Saito; Shinichiro Yamada; Katsuki Miyazaki; Yukako Takehara; Mitsuo Shimada
Journal:  Ann Gastroenterol Surg       Date:  2020-07-18

Review 5.  Efficacy and safety of the artificial pancreas in the paediatric population with type 1 diabetes.

Authors:  Susanna Esposito; Elisa Santi; Giulia Mancini; Francesco Rogari; Giorgia Tascini; Giada Toni; Alberto Argentiero; Maria Giulia Berioli
Journal:  J Transl Med       Date:  2018-06-28       Impact factor: 5.531

Review 6.  The Evolving Treatment of Diabetic Retinopathy.

Authors:  Sam E Mansour; David J Browning; Keye Wong; Harry W Flynn; Abdhish R Bhavsar
Journal:  Clin Ophthalmol       Date:  2020-03-04

7.  Leeno: Type 1 diabetes management training environment using smart algorithms.

Authors:  Mohamed Raef Smaoui; Ahmad Lafi
Journal:  PLoS One       Date:  2022-09-15       Impact factor: 3.752

Review 8.  Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital.

Authors:  Guillermo E Umpierrez; David C Klonoff
Journal:  Diabetes Care       Date:  2018-06-23       Impact factor: 19.112

Review 9.  Artificial Pancreas or Novel Beta-Cell Replacement Therapies: a Race for Optimal Glycemic Control?

Authors:  Michiel F Nijhoff; Eelco J P de Koning
Journal:  Curr Diab Rep       Date:  2018-09-24       Impact factor: 4.810

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.