Literature DB >> 26253251

An artificial pancreas provided a novel model of blood glucose level variability in beagles.

Masaya Munekage1, Tomoaki Yatabe2, Hiroyuki Kitagawa3, Yuka Takezaki3, Takahiko Tamura4, Tsutomu Namikawa3, Kazuhiro Hanazaki3.   

Abstract

Although the effects on prognosis of blood glucose level variability have gained increasing attention, it is unclear whether blood glucose level variability itself or the manifestation of pathological conditions that worsen prognosis. Then, previous reports have not been published on variability models of perioperative blood glucose levels. The aim of this study is to establish a novel variability model of blood glucose concentration using an artificial pancreas. We maintained six healthy, male beagles. After anesthesia induction, a 20-G venous catheter was inserted in the right femoral vein and an artificial pancreas (STG-22, Nikkiso Co. Ltd., Tokyo, Japan) was connected for continuous blood glucose monitoring and glucose management. After achieving muscle relaxation, total pancreatectomy was performed. After 1 h of stabilization, automatic blood glucose control was initiated using the artificial pancreas. Blood glucose level varied for 8 h, alternating between the target blood glucose values of 170 and 70 mg/dL. Eight hours later, the experiment was concluded. Total pancreatectomy was performed for 62 ± 13 min. Blood glucose swings were achieved 9.8 ± 2.3 times. The average blood glucose level was 128.1 ± 5.1 mg/dL with an SD of 44.6 ± 3.9 mg/dL. The potassium levels after stabilization and at the end of the experiment were 3.5 ± 0.3 and 3.1 ± 0.5 mmol/L, respectively. In conclusion, the results of the present study demonstrated that an artificial pancreas contributed to the establishment of a novel variability model of blood glucose levels in beagles.

Entities:  

Keywords:  Artificial pancreas; Beagle; Variability of blood glucose level

Mesh:

Substances:

Year:  2015        PMID: 26253251     DOI: 10.1007/s10047-015-0854-9

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  7 in total

Review 1.  Electrolyte disturbances associated with commonly prescribed medications in the intensive care unit.

Authors:  Mitchell S Buckley; Jaclyn M Leblanc; Michael J Cawley
Journal:  Crit Care Med       Date:  2010-06       Impact factor: 7.598

2.  Variability of blood glucose concentration and short-term mortality in critically ill patients.

Authors:  Moritoki Egi; Rinaldo Bellomo; Edward Stachowski; Craig J French; Graeme Hart
Journal:  Anesthesiology       Date:  2006-08       Impact factor: 7.892

3.  Hypoglycemia is associated with intensive care unit mortality.

Authors:  Jeroen Hermanides; Robert J Bosman; Titia M Vriesendorp; Ron Dotsch; Frits R Rosendaal; Durk F Zandstra; Joost B L Hoekstra; J Hans DeVries
Journal:  Crit Care Med       Date:  2010-06       Impact factor: 7.598

4.  The evaluation of the ability of closed-loop glycemic control device to maintain the blood glucose concentration in intensive care unit patients.

Authors:  Tomoaki Yatabe; Rie Yamazaki; Hiroyuki Kitagawa; Takehiro Okabayashi; Koichi Yamashita; Kazuhiro Hanazaki; Masataka Yokoyama
Journal:  Crit Care Med       Date:  2011-03       Impact factor: 7.598

Review 5.  Guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients.

Authors:  Judith Jacobi; Nicholas Bircher; James Krinsley; Michael Agus; Susan S Braithwaite; Clifford Deutschman; Amado X Freire; Douglas Geehan; Benjamin Kohl; Stanley A Nasraway; Mark Rigby; Karen Sands; Lynn Schallom; Beth Taylor; Guillermo Umpierrez; John Mazuski; Holger Schunemann
Journal:  Crit Care Med       Date:  2012-12       Impact factor: 7.598

6.  Pancreatic polypeptide administration reduces insulin requirements of artificial pancreas in pancreatectomized dogs.

Authors:  Tetsuya Kono; Kazuhiro Hanazaki; Kazuyuki Yazawa; Satoshi Ashizawa; William E Fisher; Xiao-Ping Wang; Yukihiko Nosé; F Charles Brunicardi
Journal:  Artif Organs       Date:  2005-01       Impact factor: 3.094

7.  The accuracy of a continuous blood glucose monitor during surgery.

Authors:  Koichi Yamashita; Takehiro Okabayashi; Takeshi Yokoyama; Tomoaki Yatabe; Hiromichi Maeda; Masanobu Manabe; Kazuhiro Hanazaki
Journal:  Anesth Analg       Date:  2008-01       Impact factor: 5.108

  7 in total
  4 in total

1.  Comparison between a novel and conventional artificial pancreas for perioperative glycemic control using a closed-loop system.

Authors:  Tsutomu Namikawa; Masaya Munekage; Hiroyuki Kitagawa; Tomoaki Yatabe; Hiromichi Maeda; Yuuki Tsukamoto; Kenichi Hirano; Takuji Asano; Yoshihiko Kinoshita; Kazuhiro Hanazaki
Journal:  J Artif Organs       Date:  2016-09-20       Impact factor: 1.731

Review 2.  Current status and issues of the artificial pancreas: abridged English translation of a special issue in Japanese.

Authors:  Tsutomu Namikawa; Masaya Munekage; Tomoaki Yatabe; Hiroyuki Kitagawa; Kazuhiro Hanazaki
Journal:  J Artif Organs       Date:  2018-01-22       Impact factor: 1.731

3.  Impact of using a perioperative artificial endocrine pancreas in pancreatic resection.

Authors:  Toshiaki Yoshimoto; Tetsuya Ikemoto; Yuji Morine; Satoru Imura; Yu Saito; Shinichiro Yamada; Katsuki Miyazaki; Yukako Takehara; Mitsuo Shimada
Journal:  Ann Gastroenterol Surg       Date:  2020-07-18

Review 4.  Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

Authors:  Kazuhiro Hanazaki; Masaya Munekage; Hiroyuki Kitagawa; Tomoaki Yatabe; Eri Munekage; Mai Shiga; Hiromichi Maeda; Tsutomu Namikawa
Journal:  J Artif Organs       Date:  2016-05-03       Impact factor: 1.731

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.