Literature DB >> 21491113

Evaluation of artificial pancreas technology for continuous blood glucose monitoring in dogs.

Akihiro Mori1, Peter Lee, Takeshi Yokoyama, Hitomi Oda, Kaori Saeki, Yohei Miki, Satoshi Nozawa, Daigo Azakami, Yutaka Momota, Yuki Makino, Takako Matsubara, Motohisa Osaka, Katsumi Ishioka, Toshiro Arai, Toshinori Sako.   

Abstract

Artificial pancreas technology, involving "closed-loop" controls with real-time blood glucose monitoring, has been increasing in reliability as its potential for clinical use and application grows. One such device, based on this technology, is the STG-22 (Nikkiso Co., Ltd., Tokyo, Japan) artificial pancreas apparatus. In order to assess the reliability and accuracy of the device for measuring blood glucose, it is important to compare its readings to those obtained using a 'gold standard' method, such as the hexokinase method. Therefore, in the present study, canine blood [glucose] measurements using the STG-22 were compared to those obtained using a previously established commercial reagent, Quickauto-Neo GLU-HK. Furthermore, two different sample types (whole blood versus plasma constituent) were compared to determine which sample type results in more accurate and optimal readings with the STG-22. Given that the STG-22 was not primarily designed for canine blood samples, results for canine blood samples were not accurate. Measurements performed by the STG-22 with whole blood were significantly lower than reference [glucose] counterparts. Alternatively, an opposite trend was observed with plasma measurements that were significantly higher. A conversion format using the following formula, Hexokinase [glucose] = STG-22 [glucose] × 1.407 + 1.532, was observed with canine samples in our study.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21491113     DOI: 10.1007/s10047-011-0560-1

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  17 in total

1.  Time-action profile of the long-acting insulin analog insulin glargine (HOE901) in comparison with those of NPH insulin and placebo.

Authors:  L Heinemann; R Linkeschova; K Rave; B Hompesch; M Sedlak; T Heise
Journal:  Diabetes Care       Date:  2000-05       Impact factor: 19.112

2.  Diabetes mellitus after resection of hepatocellular carcinoma with hypoglycemia in a dog.

Authors:  Manabu Sakai; Kazushi Asano; Makoto Nakata; Tomoko Takahashi; Hiroshi Koie; Yoshiki Yamaya; Toshihiro Watari; Hisashi Shibuya; Tsuneo Sato; Mikihiko Tokuriki; Atsuhiko Hasegawa
Journal:  J Vet Med Sci       Date:  2006-07       Impact factor: 1.267

3.  A new method for the continuous monitoring of blood glucose by measurement of dissolved oxygen.

Authors:  A H Kadish; D A Hall
Journal:  Clin Chem       Date:  1965-09       Impact factor: 8.327

4.  Type 1 diabetes developed in a type 2 diabetic patient with severe insulin resistance.

Authors:  Tadashi Suehiro; Fumiaki Osaki; Yukio Ikeda; Kaoru Arii; Fumi Nakayama; Kikuko Ota; Kozo Hashimoto
Journal:  Diabetes Res Clin Pract       Date:  2005-06-13       Impact factor: 5.602

5.  Impaired feedback inhibition of insulin secretion by hyperinsulinemia in patients with insulinoma.

Authors:  S Hiramatsu; Y Sako; K Mimura; Y Ono; K Iwashige; S Taniguchi; F Umeda; H Nawata
Journal:  Endocr J       Date:  1995-02       Impact factor: 2.349

6.  Glycosylated hemoglobin in human and animal red cells. Role of glucose permeability.

Authors:  P J Higgins; R L Garlick; H F Bunn
Journal:  Diabetes       Date:  1982-09       Impact factor: 9.461

7.  Separation and size distribution of red blood cells of diverse size, shape, and origin by flow/hyperlayer field-flow fractionation.

Authors:  B N Barman; E R Ashwood; J C Giddings
Journal:  Anal Biochem       Date:  1993-07       Impact factor: 3.365

8.  Retrospective study of canine insulinomas: eight cases (2005-2008).

Authors:  Hiroo Madarame; Hideki Kayanuma; Takuo Shida; Ryo Tsuchiya
Journal:  J Vet Med Sci       Date:  2009-07       Impact factor: 1.267

9.  Continuous post-operative blood glucose monitoring and control using a closed-loop system in patients undergoing hepatic resection.

Authors:  Takehiro Okabayashi; Kazuhiro Hnazaki; Isao Nishimori; Takeki Sugimoto; Hiromichi Maeda; Tomoaki Yatabe; Ken Dabanaka; Michiya Kobayashi; Koichi Yamashita
Journal:  Dig Dis Sci       Date:  2007-10-13       Impact factor: 3.199

10.  Lower within-subject variability of insulin detemir in comparison to NPH insulin and insulin glargine in people with type 1 diabetes.

Authors:  Tim Heise; Leszek Nosek; Birgitte Biilmann Rønn; Lars Endahl; Lutz Heinemann; Christoph Kapitza; Eberhard Draeger
Journal:  Diabetes       Date:  2004-06       Impact factor: 9.461

View more
  2 in total

Review 1.  Journal of Artificial Organs 2011: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; A Myoui; M Nishimura; T Nishimura; S Tokunaga; Y Tomizawa; T Tomo; T Tsukiya; T Yamaoka
Journal:  J Artif Organs       Date:  2012-02-29       Impact factor: 1.731

2.  Evaluation of newly developed veterinary portable blood glucose meter with hematocrit correction in dogs and cats.

Authors:  Akihiro Mori; Hitomi Oda; Eri Onozawa; Saori Shono; Toshinori Sako
Journal:  J Vet Med Sci       Date:  2017-08-18       Impact factor: 1.267

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.