Literature DB >> 8197637

[Results of implantation of uncemented porous metal hip prostheses].

M Runkel1, U Jaeger, K Wenda, J Degreif, L Rudig, G Ritter.   

Abstract

72 patients having cementless spongy-metal hip prosthesis were reexamined by clinical and radiological check up two to seven years after implantation (average 43 months). In case of five patients hip prosthesis had to be changed due to loosening (no bony ingrowth n = 2, loosening of acetabular component due to technical faults n = 3). In correlation to clinical results 88% could be considered as excellent or good, 9% acceptable and 3% as inadequate. 10% of the patients complained about thigh pain. The typical radiological bony reactions of the surrounding bone are described. An evaluation of the radiological results can only be done under consideration of the clinical problems involved. In view of the positive results obtained in the recent time the use of spongy-metal hip prosthesis can be recommended for cementless hip joint replacement in case of younger patients. Especially in case of cemented hip joints which have become loose it will be an advantage to use spongy-metal hip prosthesis.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8197637     DOI: 10.1007/bf02588147

Source DB:  PubMed          Journal:  Unfallchirurgie        ISSN: 0340-2649


  18 in total

1.  Early clinical experience with hydroxyapatite-coated femoral implants.

Authors:  J A D'Antonio; W N Capello; O D Crothers; W L Jaffe; M T Manley
Journal:  J Bone Joint Surg Am       Date:  1992-08       Impact factor: 5.284

2.  Results of the Harris-Galante cementless hip prosthesis.

Authors:  Y H Kim; V E Kim
Journal:  J Bone Joint Surg Br       Date:  1992-01

3.  [Metal spongiosa endoprostheses for surgical revision of the hip joint].

Authors:  C Lütten; H Lorenz; W Thomas
Journal:  Z Orthop Ihre Grenzgeb       Date:  1990 Mar-Apr

4.  [Results of 5-7 year follow-up of implantation of RM isoelastic hip endoprosthesis].

Authors:  D Träger
Journal:  Unfallchirurg       Date:  1989-06       Impact factor: 1.000

5.  [Clinical results using the PM type of hip endoprosthesis].

Authors:  T Wolf; A Reichelt; P Schlepckow
Journal:  Z Orthop Ihre Grenzgeb       Date:  1988-12

6.  [Postoperative pain in cement-free femur shaft prosthesis].

Authors:  G Heimke; D Stock
Journal:  Z Orthop Ihre Grenzgeb       Date:  1986 Sep-Oct

7.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

8.  [Cast metal spongioid bone implants in animal experiments].

Authors:  M Krüger; E J Henssge; D Sellin
Journal:  Z Orthop Ihre Grenzgeb       Date:  1985 Nov-Dec

9.  [Anatomically adapted endoprosthesis of the proximal end of the femur].

Authors:  E J Henssge; H Grundei; R Etspüler; W Köller; K Fink
Journal:  Z Orthop Ihre Grenzgeb       Date:  1985 Sep-Oct

10.  Cementless prosthesis of the hip joint with "spongy metal" surface. A prospective study.

Authors:  W Plötz; R Gradinger; H Rechl; R Ascherl; S Wicke-Wittenius; E Hipp
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.