Geometric distortion in clinical MRI systems Part II: correction using a 3D phantom.

Deming Wang1, Wendy Strugnell, Gary Cowin, David M Doddrell, Richard Slaughter.   

Abstract

In this paper, we present the correction of the geometric distortion measured in the clinical magnetic resonance imaging (MRI) systems reported in the preceding paper (Part I) using a 3D method based on the phantom-mapped geometric distortion data. This method allows the correction to be made on phantom images acquired without or with the vendor correction applied. With the vendor's 2D correction applied, the method corrects for both the "residual" geometric distortion still present in the plane in which the correction method was applied (the axial plane) and the uncorrected geometric distortion along the axis normal to the plane. The evaluation of the effectiveness of the correction using this new method was carried out through analyzing the residual geometric distortion in the corrected phantom images. The results show that the new method can restore the distorted images in 3D nearly to perfection. For all the MRI systems investigated, the mean absolute deviations in the positions of the control points (along x-, y- and z-axes) measured on the corrected phantom images were all less than 0.2 mm. The maximum absolute deviations were all below approximately 0.8 mm. As expected, the correction of the phantom images acquired with the vendor's correction applied in the axial plane performed equally well. Both the geometric distortion still present in the axial plane after applying the vendor's correction and the uncorrected distortion along the z-axis have all been "restored."

Mesh:

Year:  2004        PMID: 15607093     DOI: 10.1016/j.mri.2004.08.014

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  16 in total

1.  Geometric distortion in magnetic resonance imaging systems assessed using an open-source plugin for scientific image analysis.

Authors:  Takahiro Aoyama; Hidetoshi Shimizu; Ikuo Shimizu; Atsushi Teramoto; Naoki Kaneda; Kazuhiko Nakamura; Masaru Nakamura; Takeshi Kodaira
Journal:  Radiol Phys Technol       Date:  2018-09-25

2.  Technical feasibility of integrating 7 T anatomical MRI in image-guided radiotherapy of glioblastoma: a preparatory study.

Authors:  Inge Compter; Jurgen Peerlings; Daniëlle B P Eekers; Alida A Postma; Dimo Ivanov; Christopher J Wiggins; Pieter Kubben; Benno Küsters; Pieter Wesseling; Linda Ackermans; Olaf E M G Schijns; Philippe Lambin; Aswin L Hoffmann
Journal:  MAGMA       Date:  2016-03-30       Impact factor: 2.310

3.  Head to head comparison of two commercial phantoms used for SRS QA.

Authors:  Vikren Sarkar; Long Huang; Yu-Huei Jessica Huang; Martin W Szegedi; Prema Rassiah-Szegedi; Hui Zhao; Bill J Salter
Journal:  J Radiosurg SBRT       Date:  2016

4.  Correction of gradient nonlinearity artifacts in prospective motion correction for 7T MRI.

Authors:  Uten Yarach; Chaiya Luengviriya; Appu Danishad; Daniel Stucht; Frank Godenschweger; Peter Schulze; Oliver Speck
Journal:  Magn Reson Med       Date:  2014-05-05       Impact factor: 4.668

5.  Distortion correction in whole-body imaging of live mice using a 1-Tesla compact magnetic resonance imaging system.

Authors:  Shigeru Kiryu; Yusuke Inoue; Yoshitaka Masutani; Tomoyuki Haishi; Kohki Yoshikawa; Makoto Watanabe; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-06-30       Impact factor: 2.374

6.  Are the osseous and tendinous-cartilaginous tibial tuberosity-trochlear groove distances the same on CT and MRI?

Authors:  Betina Bremer Hinckel; Riccardo Gomes Gobbi; Eduardo Noda Kihara Filho; José Ricardo Pécora; Gilberto Luis Camanho; Marcelo Bordalo Rodrigues; Marco Kawamura Demange
Journal:  Skeletal Radiol       Date:  2015-02-24       Impact factor: 2.199

7.  Evaluation of the ability of the Brainlab Elements Cranial Distortion Correction algorithm to correct clinically relevant MRI distortions for cranial SRT.

Authors:  Paul Retif; Abdourahamane Djibo Sidikou; Christian Mathis; Romain Letellier; Emilie Verrecchia-Ramos; Rémi Dupres; Xavier Michel
Journal:  Strahlenther Onkol       Date:  2022-08-18       Impact factor: 4.033

8.  Measurement of MRI scanner performance with the ADNI phantom.

Authors:  Jeffrey L Gunter; Matt A Bernstein; Brett J Borowski; Chadwick P Ward; Paula J Britson; Joel P Felmlee; Norbert Schuff; Michael Weiner; Clifford R Jack
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

9.  Radiotherapy planning using MRI.

Authors:  Maria A Schmidt; Geoffrey S Payne
Journal:  Phys Med Biol       Date:  2015-10-28       Impact factor: 3.609

10.  A method for improving the performance of gradient systems for diffusion-weighted MRI.

Authors:  Zoltan Nagy; Nikolaus Weiskopf; Daniel C Alexander; Ralf Deichmann
Journal:  Magn Reson Med       Date:  2007-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.