Literature DB >> 15586332

Wear and periprosthetic osteolysis in a match-paired study of modular and nonmodular uncemented acetabular cups.

Alejandro González Della Valle1, Edwin Su, Adriana Zoppi, Thomas P Sculco, Eduardo A Salvati.   

Abstract

The wear and prevalence of periprosthetic osteolysis at 5 to 8 years of follow-up of the Trilogy cup, which has a modular liner assembled during surgery, was compared with the Implex cup, which has a fixed liner preassembled at the factory. Sixty-three patients (65 hips) with a Trilogy cup and 64 patients (65 hips) with an Implex cup were match-paired for sex, age, height, weight, and diagnosis (osteoarthritis). All patients had a cemented stem with a 28-mm head and a successful clinical and radiographic result. After an average follow-up of 5.65 years, radiographs were studied to determine the total penetration, using the Livermore technique, and the presence of osteolysis. The average total wear in the Trilogy group was 0.47 mm (range, 0-1.95 mm); for the Implex cup, it was 0.43 mm (range, 0-1.45 mm) (P.99). One patient in each group presented with periacetabular osteolysis (P.99). There was no difference in the wear rate and prevalence of periprosthetic osteolysis between the 2 groups.

Entities:  

Mesh:

Year:  2004        PMID: 15586332     DOI: 10.1016/j.arth.2004.06.001

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  10 in total

1.  A critical analysis of radiographic factors in patients who develop dislocation after elective primary total hip arthroplasty.

Authors:  Marion Opperer; Yuo-yu Lee; Francisco Nally; Alvaro Blanes Perez; Kaveh Goudarz-Mehdikhani; Alejandro Gonzalez Della Valle
Journal:  Int Orthop       Date:  2015-10-27       Impact factor: 3.075

2.  The utility and precision of analogue and digital preoperative planning for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Nicole Taveras; Eduardo A Salvati
Journal:  Int Orthop       Date:  2007-04-03       Impact factor: 3.075

3.  Wear is reduced in THA performed with highly cross-linked polyethylene.

Authors:  Burak Beksaç; Antonio Salas; Alejandro González Della Valle; Eduardo A Salvati
Journal:  Clin Orthop Relat Res       Date:  2008-12-12       Impact factor: 4.176

Review 4.  Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty?

Authors:  Jelle J Halma; H Charles Vogely; Wouter J Dhert; Steven M Van Gaalen; Arthur de Gast
Journal:  Clin Orthop Relat Res       Date:  2013-08-03       Impact factor: 4.176

5.  High failure rate of a modern, proximally roughened, cemented stem for total hip arthroplasty.

Authors:  A Grose; A González Della Valle; P Bullough; S Lyman; I Tomek; P Pellicci
Journal:  Int Orthop       Date:  2006-04-29       Impact factor: 3.075

6.  Second-generation modular acetabular components provide fixation at 10 to 16 years.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

7.  Similar wear in total hip arthroplasties with metallic or zirconia femoral heads.

Authors:  Randy M Cohn; Alejandro González Della Valle; Margaret Peterson; Charles N Cornell
Journal:  HSS J       Date:  2008-07-15

8.  Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips.

Authors:  Thomas Baad-Hansen; Søren Kold; Poul Torben Nielsen; Mogens Berg Laursen; Poul Hedevang Christensen; Kjeld Soballe
Journal:  Acta Orthop       Date:  2011-03-25       Impact factor: 3.717

9.  Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro.

Authors:  Ana Laura Puente Reyna; Marcus Jäger; Thilo Floerkemeier; Sven Frecher; Karl-Stefan Delank; Christoph Schilling; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2016-09-19       Impact factor: 3.411

10.  Survival of uncemented acetabular monoblock cups: evaluation of 210 hips in the Swedish Hip Arthroplasty Register.

Authors:  Rüdiger J Weiss; Nils P Hailer; André Stark; Johan Kärrholm
Journal:  Acta Orthop       Date:  2012-05-10       Impact factor: 3.717

  10 in total