Literature DB >> 15578545

Development and validation of a second-generation metal-on-metal bearing: laboratory studies and analysis of retrievals.

Claude B Rieker1, Rolf Schön, Petra Köttig.   

Abstract

This paper summarizes hip simulator and retrieval studies that were done to optimize 1 design of a second-generation metal-on-metal hip replacement. It was determined that clearance is the first key parameter controlling wear behaviour. The clearance should be as small as possible while as large as necessary to avoid any equatorial contact leading to clamping of the articulation. The minimum clearance should be investigated for each different design. Carbon concentration should be in the range 0.20-0.25% as high carbon concentration alloys have systematically a lower wear rate than low carbon alloys. The wear of clinically retrieved implants confirms the predicted low wear of this implant and confirms the importance of the clearance and the type of cobalt-chrome alloy.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15578545     DOI: 10.1016/j.arth.2004.09.017

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  18 in total

1.  Cup loosening after cemented Metasul® total hip replacement: a retrieval analysis.

Authors:  Christophe Nich; Moussa Hamadouche
Journal:  Int Orthop       Date:  2010-06-11       Impact factor: 3.075

Review 2.  Revision arthroplasty: an update.

Authors:  D Williams; A Taylor; P McLardy-Smith
Journal:  Skeletal Radiol       Date:  2009-11       Impact factor: 2.199

Review 3.  The clinical performance of metal-on-metal as an articulation surface in total hip replacement.

Authors:  William T Long
Journal:  Iowa Orthop J       Date:  2005

4.  [Complications of metal-on-metal tribological pairing].

Authors:  M Stiehler; F Zobel; F Hannemann; J Schmitt; J Lützner; S Kirschner; K-P Günther; A Hartmann
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

5.  What Is the Long-term Survival for Primary THA With Small-head Metal-on-metal Bearings?

Authors:  Richard de Steiger; Andrea Peng; Peter Lewis; Stephen Graves
Journal:  Clin Orthop Relat Res       Date:  2018-06       Impact factor: 4.176

6.  Predictors of participation in sports after hip and knee arthroplasty.

Authors:  Daniel H Williams; Nelson V Greidanus; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

7.  Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys.

Authors:  A Igual Muñoz; S Mischler
Journal:  J Mater Sci Mater Med       Date:  2011-01-11       Impact factor: 3.896

8.  2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.

Authors:  C Anderson Engh; Steven J MacDonald; Supatra Sritulanondha; Abigail Thompson; Douglas Naudie; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

9.  Risk of impingement and third-body abrasion with 28-mm metal-on-metal bearings.

Authors:  Ian C Clarke; Jean-Yves Lazennec; Adrien Brusson; Christina Savisaar; John G Bowsher; Michelle Burgett; Thomas K Donaldson
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

10.  Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis.

Authors:  Jean-Yves Lazennec; Patrick Boyer; Joel Poupon; Marc-Antoine Rousseau; Carine Roy; Philippe Ravaud; Yves Catonné
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.