Literature DB >> 15573923

Comparison of air-coupled balloon esophageal and anorectal manometry catheters with solid-state esophageal manometry and water-perfused anorectal manometry catheters.

John C Fang1, Kristen Hilden, Ashok K Tuteja, Kathryn A Peterson.   

Abstract

Clinical gastrointestinal manometry studies are currently performed with multilumen water-perfused polyvinyl or strain gauge sensor solid-state catheters. A disposable catheter incorporating air-filled balloons has been developed with performance characteristics suitable for esophageal and anorectal manometry studies. Our aim was to compare esophageal and anorectal pressure measurements using this newly developed catheter with measurements obtained using standard solid-state or water-perfused catheters. Measurements of resting LES pressure, esophageal contraction amplitudes, and anorectal rest and squeeze pressures were obtained in 10 healthy volunteers using a solid-state esophageal catheter, a water-perfused anorectal catheter, and air-filled balloon esophageal and anorectal catheters. Correlation coefficient analysis demonstrated that LES pressures, esophageal contraction amplitudes, and anorectal resting and squeeze pressures were not significantly among between the different catheters. We conclude that recently developed air-filled balloon esophageal and anorectal manometry catheters provide very similar measurements of LES, esophageal body, and anorectal sphincter pressures compared to presently used manometry catheters.

Entities:  

Mesh:

Year:  2004        PMID: 15573923     DOI: 10.1023/b:ddas.0000043382.59539.d3

Source DB:  PubMed          Journal:  Dig Dis Sci        ISSN: 0163-2116            Impact factor:   3.199


  11 in total

1.  A cost and performance evaluation of disposable and reusable biopsy forceps in GI endoscopy.

Authors:  R Yang; S Ng; M Nichol; L Laine
Journal:  Gastrointest Endosc       Date:  2000-03       Impact factor: 9.427

2.  Ultrathin crossroads: is smaller better?

Authors:  V Alin Botoman
Journal:  Gastrointest Endosc       Date:  2003-03       Impact factor: 9.427

Review 3.  Minimum standards of anorectal manometry.

Authors:  S S C Rao; F Azpiroz; N Diamant; P Enck; G Tougas; A Wald
Journal:  Neurogastroenterol Motil       Date:  2002-10       Impact factor: 3.598

4.  Comparison of two intrauterine pressure catheters during labor.

Authors:  Mark A Dowdle
Journal:  J Reprod Med       Date:  2003-07       Impact factor: 0.142

5.  Comparison of lower oesophageal sphincter pressure measurement using circumferential vs unidirectional transducers.

Authors:  K G Pursnani; C Oeffner; R M Gideon; D O Castell
Journal:  Neurogastroenterol Motil       Date:  1997-09       Impact factor: 3.598

6.  A new technique for continuous sphincter pressure measurement.

Authors:  J Dent
Journal:  Gastroenterology       Date:  1976-08       Impact factor: 22.682

Review 7.  American Gastroenterological Association technical review on the clinical use of esophageal manometry.

Authors:  P J Kahrilas; R E Clouse; W J Hogan
Journal:  Gastroenterology       Date:  1994-12       Impact factor: 22.682

8.  Evaluating a new intrauterine pressure catheter.

Authors:  M Dowdle
Journal:  J Reprod Med       Date:  1997-08       Impact factor: 0.142

9.  Accurate placement of the esophageal pH electrode for 24-hour pH monitoring using a combined pH/manometry probe.

Authors:  P J Klingler; R A Hinder; G J Wetscher; D M Davis; S R Achem; M H Seelig; P O'Brien; K R DeVault
Journal:  Am J Gastroenterol       Date:  2000-04       Impact factor: 10.864

10.  Contamination of single-use biopsy forceps: a prospective in vitro analysis.

Authors:  Timothy P Kinney; Richard A Kozarek; Shirley Raltz; Fouad Attia
Journal:  Gastrointest Endosc       Date:  2002-08       Impact factor: 9.427

View more
  4 in total

1.  Development of a wireless intra-vaginal transducer for monitoring intra-abdominal pressure in women.

Authors:  Tanner J Coleman; Jens C Thomsen; Sean D Maass; Yvonne Hsu; Ingrid E Nygaard; Robert W Hitchcock
Journal:  Biomed Microdevices       Date:  2012-04       Impact factor: 2.838

Review 2.  High-Resolution Anorectal Manometry - New Insights in the Diagnostic Assessment of Functional Anorectal Disorders.

Authors:  Henriette Heinrich; Benjamin Misselwitz
Journal:  Visc Med       Date:  2018-04-20

3.  Development of a novel intra-vaginal transducer with improved dynamic response.

Authors:  Paul J Johnson; Evan M Rosenbluth; Ingrid E Nygaard; Monir K Parikh; Robert W Hitchcock
Journal:  Biomed Microdevices       Date:  2009-12       Impact factor: 2.838

Review 4.  Expert consensus document: Advances in the evaluation of anorectal function.

Authors:  Emma V Carrington; S Mark Scott; Adil Bharucha; François Mion; Jose M Remes-Troche; Allison Malcolm; Henriette Heinrich; Mark Fox; Satish S Rao
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2018-04-11       Impact factor: 46.802

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.