Assessment of the problem: pediatric doses in screen-film and digital radiography.

W Huda1.   

Abstract

In diagnostic radiology, radiation exposure measures the amount of radiation at a given location in an x-ray beam, dose measures the energy deposited in a specified absorber, and equivalent dose quantifies the biological harm expected from this deposited energy. The effective dose attempts to account for the energy deposited in all irradiated organs as well as their relative radiosensitivity, and is the best available descriptor of the stochastic patient risk. Effective doses can be estimated from measures of the radiation beam incident on the patient as either entrance skin dose or dose-area product in conjunction with appropriate conversion coefficients. These effective dose-conversion coefficients are influenced by the patient size, exposed body region, x-ray beam quality, and x-ray beam area. We present values of skin dose, dose-area product, and effective dose for common examinations in pediatric patients whose size ranges from the newborn to adolescents. In screen-film radiography, the system speed defines the amount of radiation required to generate a satisfactory radiographic film density. Changing the screen thickness normally modifies the speed of screen-film systems, which affects the system resolution but not the level of image noise (mottle). By contrast, digital systems have a fixed resolution but can operate satisfactorily over a wide range of receptor dose, with the amount of noise in the resultant image being inversely related to the amount of radiation used. To ensure that patient doses are kept as low as reasonably achievable (ALARA), it is essential that digital receptor doses be monitored to ensure they stay constant. It is also important that protocols in digital radiography are specific for the imaging task to be performed, and use no more radiation than needed to achieve a satisfactory diagnosis.

Entities:  

Mesh:

Year:  2004        PMID: 15558259     DOI: 10.1007/s00247-004-1267-8

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  10 in total

1.  Detection of pulmonary arterial morphology in tetralogy of Fallot with pulmonary atresia by computed tomography: 12 years of experience.

Authors:  Ming-Tai Lin; Jou-Kou Wang; Yih-Sharng Chen; Wen-Jeng Lee; Hsin-Hui Chiu; Chun-An Chen; Shuenn-Nan Chiu; En-Ting Wu; Chun-Wei Lu; Shu-Chien Huang; Shyh-Jye Chen; Ing-Sh Chiu; Chung-I Chang; Mei-Hwan Wu
Journal:  Eur J Pediatr       Date:  2011-11-15       Impact factor: 3.183

2.  Digital radiography: optimization of image quality and dose using multi-frequency software.

Authors:  H Precht; O Gerke; K Rosendahl; A Tingberg; D Waaler
Journal:  Pediatr Radiol       Date:  2012-04-17

3.  Optimization of image quality and patient dose in radiographs of paediatric extremities using direct digital radiography.

Authors:  A Jones; C Ansell; C Jerrom; I D Honey
Journal:  Br J Radiol       Date:  2015-03-27       Impact factor: 3.039

4.  Avoiding CT scans in children with single-suture craniosynostosis.

Authors:  T Schweitzer; H Böhm; P Meyer-Marcotty; H Collmann; R-I Ernestus; J Krauß
Journal:  Childs Nerv Syst       Date:  2012-02-19       Impact factor: 1.475

Review 5.  Oncological imaging: tumor surveillance in children.

Authors:  Sue C Kaste
Journal:  Pediatr Radiol       Date:  2011-08-17

6.  Pediatric patient surface doses in neuroangiography.

Authors:  Natalie A Swoboda; Derek G Armstrong; John Smith; Ellen Charkot; Bairbre L Connolly
Journal:  Pediatr Radiol       Date:  2005-05-26

7.  Optimising the use of computed radiography in pediatric chest imaging.

Authors:  R Sanchez Jacob; E Vano-Galvan; E Vano; N Gomez Ruiz; J M Fernandez Soto; D Martinez Barrio; C Prieto
Journal:  J Digit Imaging       Date:  2007-09-13       Impact factor: 4.056

8.  National survey of radiation doses of pediatric chest radiography in Korea: analysis of the factors affecting radiation doses.

Authors:  Bo Hyun Kim; Kyung-Hyun Do; Hyun Woo Goo; Dong Hyun Yang; Sang Young Oh; Hyeog Ju Kim; Kwang Yong Lee; Jung Eun Lee
Journal:  Korean J Radiol       Date:  2012-08-28       Impact factor: 3.500

Review 9.  Patient dose reduction during voiding cystourethrography.

Authors:  Valerie L Ward
Journal:  Pediatr Radiol       Date:  2006-09

Review 10.  [Chest X-rays in children and adolescents : Indications and limitations].

Authors:  Diane Miriam Renz; Carolin Huisinga; Alexander Pfeil; Joachim Böttcher; Nicolaus Schwerk; Florian Streitparth; Jürgen Weidemann
Journal:  Radiologe       Date:  2022-01-18       Impact factor: 0.635

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.