Literature DB >> 15552422

Development of an inorganic scintillating mixture for proton beam verification dosimetry.

Sairos Safai1, Shixiong Lin, Eros Pedroni.   

Abstract

The availability at the Paul Scherrer Institute (PSI) of a spot-scanning technique with an isocentric beam delivery system (gantry) allows the realization of intensity-modulated proton therapy (IMPT). The development of 3D dosimetry is an important tool for the verification of IMPT therapy plans based on inhomogeneous 3D conformal dose distributions. For that purpose new dosimeters are being developed. The concept is to use a system of many millimetre sized scintillating volumes distributed in a polyethylene block, which are read on a CCD camera over a bundle of optical fibres and which can be irradiated from any direction orthogonal to the fibre axis. The purpose of this work is to investigate the composition of such small sensitive volumes. A mixture of inorganic phosphors and optical cement allows an optimal coupling between the scintillating volume and the optical fibre. Five different inorganic phosphors, available as powder, have been examined by considering their response along the Bragg curve. In particular, two phosphors have shown interesting behaviours: Gd2O2S:Tb and (Zn, Cd)S:Ag. Both phosphors have a high emission efficiency but contrasting behaviour in the Bragg peak region. The efficiency of Gd2O2S:Tb decreases with increasing stopping power (quenching of luminescence) while that of (Zn, Cd)S:Ag increases. Because of these contrasting behaviours it is possible to prepare a mixture of the two scintillating powders in a certain ratio in order to modulate the height of the measured Bragg peak relative to the entrance value so that it is in agreement with the ionization chamber measurements. We propose to use a mixture for the sensitive volume consisting of the following weight fractions: 48% Gd2O2S:Tb, 12% (Zn, Cd)S:Ag and 40% optical cement.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15552422     DOI: 10.1088/0031-9155/49/19/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system.

Authors:  L Archambault; F Poenisch; N Sahoo; D Robertson; A Lee; M T Gillin; R Mohan; S Beddar
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Characterizing the response of miniature scintillation detectors when irradiated with proton beams.

Authors:  Louis Archambault; Jerimy C Polf; Luc Beaulieu; Sam Beddar
Journal:  Phys Med Biol       Date:  2008-03-10       Impact factor: 3.609

Review 3.  Treatment planning optimisation in proton therapy.

Authors:  S E McGowan; N G Burnet; A J Lomax
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

4.  Polyenergetic Data Acquisition Using a Video-Scintillator Detector for Scanned Proton Beams.

Authors:  John G Eley; Daniel R Strauss; Ulrich W Langner
Journal:  Int J Part Ther       Date:  2017-03-14

5.  Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams.

Authors:  L L W Wang; L A Perles; L Archambault; N Sahoo; D Mirkovic; S Beddar
Journal:  Phys Med Biol       Date:  2012-11-06       Impact factor: 3.609

6.  Characterization of a Low-Cost Plastic Fiber Array Detector for Proton Beam Dosimetry.

Authors:  Cigdem Ozkan Loch; Michael Alexander Eichenberger; Michele Togno; Simon Pascal Zinsli; Martina Egloff; Angela Papa; Rasmus Ischebeck; Antony John Lomax; Peter Peier; Sairos Safai
Journal:  Sensors (Basel)       Date:  2020-10-09       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.