Literature DB >> 15551792

Measurements of occupational exposure for a technologist performing 18F FDG PET scans.

Talma Biran1, Jolie Weininger, Shalom Malchi, Rami Marciano, Roland Chisin.   

Abstract

Radiation doses to one PET technologist performing 100 18F FDG (18F fluorodeoxyglucose) imaging procedures were measured in a clinical setting using two types of thermoluminescent dosimeter (TLD) badges, one finger-ring TLD and one electronic pocket dosimeter (EPD). 18F FDG was handled either with unshielded or with viewing window tungsten shielded syringes. The resulting doses using unshielded syringes were 13.8 +/- 0.8 microSv/370 MBq and 14.3 +/- 0.4 microSv/370 MBq, measured with TLD 100 and with TLD 700H/600H, respectively. For the same series of measurements, the doses obtained using shielded syringes were 10.7 +/- 0.4 microSv/370 MBq and 7.2 +/- 2.1 microSv/370 MBq with TLD700H/600H and with EPD, respectively. The dose to the right hand from shielded syringes was 69.3 +/- 5.5 microSv/370 MBq. All these values are within the ICRP recommended dose limits. Extrapolated to 725 examinations per year, the resulting effective dose measured with TLD would be 10 mSv with unshielded and 7.5 mSv with shielded syringes, respectively (25% dose reduction). The doses measured by TLD were consistently higher than those measured by EPD, suggesting that EPD measurements might underestimate occupational doses.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15551792     DOI: 10.1097/01.hp.0000137180.85643.9d

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  4 in total

1.  Validation of a new protocol for ¹⁸F-FDG infusion using an automatic combined dispenser and injector system.

Authors:  Michela Lecchi; Giovanni Lucignani; Claudio Maioli; Giuseppe Ignelzi; Angelo Del Sole
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-06-28       Impact factor: 9.236

2.  Occupational radiation dose associated with Rb-82 myocardial perfusion positron emission tomography imaging.

Authors:  A Robert Schleipman; Frank P Castronovo; Marcelo F Di Carli; Sharmila Dorbala
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

3.  Comprehensive evaluation of occupational radiation exposure to intraoperative and perioperative personnel from 18F-FDG radioguided surgical procedures.

Authors:  Stephen P Povoski; Ismet Sarikaya; William C White; Steven G Marsh; Nathan C Hall; George H Hinkle; Edward W Martin; Michael V Knopp
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-07-10       Impact factor: 9.236

4.  Investigation of LiF, Mg and Ti (TLD-100) Reproducibility.

Authors:  M Sadeghi; S Sina; R Faghihi
Journal:  J Biomed Phys Eng       Date:  2015-12-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.