Literature DB >> 15547220

MR arthrography of the hip: diagnostic performance of a dedicated water-excitation 3D double-echo steady-state sequence to detect cartilage lesions.

Patrick R Knuesel1, Christian W A Pfirrmann, Hubert P Noetzli, Claudio Dora, Marco Zanetti, Juerg Hodler, Bernd Kuehn, Marius R Schmid.   

Abstract

OBJECTIVE: The objective of our study was to compare the diagnostic performance of a dedicated cartilage MR sequence (water-excitation 3D double-echo steady-state) with a standard MR sequence (T1-weighted spin-echo) in detecting articular cartilage lesions of the hip after intraarticular injection of gadopentetate dimeglumine.
MATERIALS AND METHODS: In 50 MR arthrograms of the hip joint obtained in 47 consecutive patients, a sagittal 3D double-echo steady-state sequence (TR/TE, 24/6.5; flip angle, 25 degrees ) was compared with a sagittal T1-weighted spin-echo sequence (350/14). Two musculoskeletal radiologists independently evaluated articular cartilage. Sensitivity and specificity for detecting cartilage defects were calculated for those hips that underwent open surgery (n = 21). Lesion conspicuity was retrospectively reviewed and graded between 1 (not visible) and 5 (well defined).
RESULTS: At surgery, a total of 26 lesions of the acetabular (n = 20) and femoral (n = 6) cartilage were found. For the 3D double-echo steady-state and T1-weighted spin-echo sequences, sensitivities and specificities for cartilage lesion detection were 58% and 88% and 81% and 81% for reviewer 1 and 62% and 94% and 62% and 100% for reviewer 2, respectively. Lesion conspicuity was significantly superior (p = 0.036) for the 3D double-echo steady-state sequence (mean grade, 3.4) compared with the T1-weighted spin-echo sequence (mean grade, 3.0). The kappa value was fair for the 3D double-echo steady-state sequence (kappa = 0.40) and moderate for the T1-weighted spin-echo sequence (kappa = 0.55).
CONCLUSION: The 3D double-echo steady-state sequence optimized for cartilage imaging improves lesion conspicuity but does not improve diagnostic performance.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15547220     DOI: 10.2214/ajr.183.6.01831729

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  17 in total

1.  Elite Rowers Demonstrate Consistent Patterns of Hip Cartilage Damage Compared With Matched Controls: A T2* Mapping Study.

Authors:  Bernd Bittersohl; Chiara Benedikter; Alexander Franz; Tobias Hesper; Christoph Schleich; Gerald Antoch; Harish S Hosalkar; Rüdiger Krauspe; Christoph Zilkens
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

2.  Comparison of pre-operative dGEMRIC imaging with intra-operative findings in femoroacetabular impingement: preliminary findings.

Authors:  Bernd Bittersohl; Harish S Hosalkar; Sebastian Apprich; Stefan A Werlen; Klaus A Siebenrock; Tallal Charles Mamisch
Journal:  Skeletal Radiol       Date:  2010-10-13       Impact factor: 2.199

Review 3.  [Radiological diagnosis of femoroacetabular impingement].

Authors:  T C Mamisch; S Werlen; C Zilkens; S Trattnig; Y-J Kim; K A Siebenrock; B Bittersohl
Journal:  Radiologe       Date:  2009-05       Impact factor: 0.635

Review 4.  Imaging of snapping phenomena.

Authors:  R Guillin; A J Marchand; A Roux; E Niederberger; R Duvauferrier
Journal:  Br J Radiol       Date:  2012-06-27       Impact factor: 3.039

5.  3D double-echo steady-state with water excitation MR imaging of the intraparotid facial nerve at 1.5T: a pilot study.

Authors:  Y Qin; J Zhang; P Li; Y Wang
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-12       Impact factor: 3.825

6.  MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences.

Authors:  Giovanni Foti; Paolo Avanzi; William Mantovani; Flavia Dal Corso; Emanuele Demozzi; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2017-02-15       Impact factor: 3.469

7.  MR arthrography of the hip: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences.

Authors:  Giovanni Foti; Antonio Campacci; Michele Conati; Mirko Trentadue; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2017-06-09       Impact factor: 3.469

Review 8.  Routine 3D magnetic resonance imaging of joints.

Authors:  Richard Kijowski; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

9.  Accuracy of 3D dual echo steady state (DESS) MR arthrography to quantify acetabular cartilage thickness.

Authors:  Christine L Abraham; Neal K Bangerter; Lance S McGavin; Christopher L Peters; Alex J Drew; Christopher J Hanrahan; Andrew E Anderson
Journal:  J Magn Reson Imaging       Date:  2015-04-06       Impact factor: 4.813

10.  3D double-echo steady-state sequence assessment of hip joint cartilage and labrum at 3 Tesla: comparative analysis of magnetic resonance imaging and intraoperative data.

Authors:  Christoph Schleich; Tobias Hesper; Harish S Hosalkar; Fanni Rettegi; Christoph Zilkens; Rüdiger Krauspe; Gerald Antoch; Bernd Bittersohl
Journal:  Eur Radiol       Date:  2017-04-21       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.