Evaluation of a soft-handling computerized pneumatic tube specimen delivery system. Effects on analytical results and turnaround time.

A A Keshgegian1, G E Bull.   

Abstract

A computerized pneumatic tube specimen delivery system with system-wide air cushion soft handling features was evaluated. There were no significant differences in values (largely normal) for components of a standard chemical profile or complete blood count in specimens delivered from the outpatient center or neonatal intensive care unit by pneumatic tube compared to couriers. The pneumatic tube system also did not affect values for pO2, pCO2, and pH over a wide range (pO2, 25 to 438 mmHg) in specimens sent from the operating room during cardiac surgery. The pneumatic tube system decreased the median turnaround time for potassium and hemoglobin results on specimens from the emergency department by 25%. The system evaluated is a rapid, efficient mechanism for sending specimens to the clinical laboratory that produces no significant effects on analytical results and has the ability to decrease turnaround time.

Entities:  

Mesh:

Year:  1992        PMID: 1553919     DOI: 10.1093/ajcp/97.4.535

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  9 in total

1.  Changes in blood gas samples produced by a pneumatic tube system.

Authors:  P O Collinson; C M John; D C Gaze; L F Ferrigan; D G Cramp
Journal:  J Clin Pathol       Date:  2002-02       Impact factor: 3.411

2.  An Audit of VDRL Testing from an STI Clinic in India: Analysing the Present Scenario with Focus on Estimating and Optimizing the Turnaround Time.

Authors:  Bhanu Mehra; Preena Bhalla; Deepti Rawat; Shikhar Saxena
Journal:  J Clin Diagn Res       Date:  2015-08-01

3.  Laboratory turnaround time.

Authors:  Robert C Hawkins
Journal:  Clin Biochem Rev       Date:  2007-11

4.  Drone Transport of Microbes in Blood and Sputum Laboratory Specimens.

Authors:  Timothy K Amukele; Jeff Street; Karen Carroll; Heather Miller; Sean X Zhang
Journal:  J Clin Microbiol       Date:  2016-08-17       Impact factor: 5.948

5.  Hemolysis associated with pneumatic tube system transport for blood samples.

Authors:  Hasan Kara; Aysegul Bayir; Ahmet Ak; Selim Degirmenci; Murat Akinci; Ahmet Agacayak; Emine Marcil; Melih Azap
Journal:  Pak J Med Sci       Date:  2014-01       Impact factor: 1.088

6.  Can Unmanned Aerial Systems (Drones) Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?

Authors:  Timothy K Amukele; Lori J Sokoll; Daniel Pepper; Dana P Howard; Jeff Street
Journal:  PLoS One       Date:  2015-07-29       Impact factor: 3.240

7.  The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests.

Authors:  Fatma Emel Koçak; Mustafa Yöntem; Ozlem Yücel; Mustafa Cilo; Ozlem Genç; Ayfer Meral
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

8.  Assessing Safety of Pneumatic Tube System (PTS) for Patients with Very Low Hematologic Parameters.

Authors:  Mustafa Koroglu; Mehmet Ali Erkurt; Irfan Kuku; Emin Kaya; Ilhami Berber; Ilknur Nizam; Yavuz Yagar; Seyit Ali Kayis
Journal:  Med Sci Monit       Date:  2016-04-20

9.  The Effects of Sample Transport by Pneumatic Tube System on Routine Hematology and Coagulation Tests.

Authors:  Devi Subbarayan; Chidambharam Choccalingam; Chittode Kodumudi Anantha Lakshmi
Journal:  Adv Hematol       Date:  2018-07-02
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.