An Audit of VDRL Testing from an STI Clinic in India: Analysing the Present Scenario with Focus on Estimating and Optimizing the Turnaround Time.

Bhanu Mehra1, Preena Bhalla2, Deepti Rawat3, Shikhar Saxena4.   

Abstract

BACKGROUND: Timeliness of reporting is of utmost importance to limit the spread of syphilis. The present analysis was undertaken to evaluate the turnaround time of syphilis testing (mainly Venereal disease research laboratory /VDRL test) in a sexually transmitted infections (STI) clinic in India; to find out the possible reasons for delay; to describe the trends of clinical indications for syphilis testing from an STI clinic; to assess the frequency of a positive syphilis serology among STI clinic attendees; and to analyse the follow-up rates of VDRL report collection.
MATERIALS AND METHODS: Two hundred consecutive VDRL requests received at the serology laboratory of a tertiary care health facility from the STI clinic of the linked hospital were prospectively analysed to evaluate the above parameters.
RESULTS: For the 200 requests audited, the mean absolute turnaround time of VDRL test was 7.46±2.81 days. The mean duration of the pre-laboratory, laboratory and post laboratory phases was 0, 4.69±2.13 and 2.77±2.51 days respectively. The interval from specimen receipt to performance of tests (mean duration=4.25±1.96 days) was the major reason for long VDRL turnaround time. The common indications for syphilis testing in STI clinic attendees were lower abdominal pain (33%), vaginal discharge (26.5%) and genital ulcer disease (9%); and the follow-up rate for report collection was 71%.
CONCLUSION: Our study highlights the strong need to shift to alternative testing methods, mainly rapid point of care procedures for serodiagnosis of syphilis in order to circumvent the problems of long turnaround time and low patient follow-up rates.

Entities:  

Keywords:  Serology laboratory; Syphilis; Timeliness

Year:  2015        PMID: 26435966      PMCID: PMC4576558          DOI: 10.7860/JCDR/2015/14179.6302

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  17 in total

Review 1.  Turnaround times in the laboratory: a review of the literature.

Authors:  P G Manor
Journal:  Clin Lab Sci       Date:  1999 Mar-Apr

Review 2.  Near patient testing and pathology in the new millennium.

Authors:  M A Crook
Journal:  J Clin Pathol       Date:  2000-01       Impact factor: 3.411

3.  Local audit of surgical pathology. 18 month's experience of peer review-based quality assessment in an English teaching hospital.

Authors:  A D Ramsay; P J Gallagher
Journal:  Am J Surg Pathol       Date:  1992-05       Impact factor: 6.394

4.  Reproducibility (precision) in alternate site testing. A clinician's perspective.

Authors:  N B Watts
Journal:  Arch Pathol Lab Med       Date:  1995-10       Impact factor: 5.534

5.  Physician goals and laboratory test turnaround times. A College of American Pathologists Q-Probes study of 2763 clinicians and 722 institutions.

Authors:  P J Howanitz; G S Cembrowski; S J Steindel; T A Long
Journal:  Arch Pathol Lab Med       Date:  1993-01       Impact factor: 5.534

6.  Computers in total quality management. Statistical process control to expedite stats.

Authors:  J L Rollo; B A Fauser
Journal:  Arch Pathol Lab Med       Date:  1993-09       Impact factor: 5.534

7.  Computer-generated management tools for the clinical pathology laboratory. II. Computer-generated graphic work flow.

Authors:  D M Bloch
Journal:  J Med Syst       Date:  1982-06       Impact factor: 4.460

8.  Using outlier events to monitor test turnaround time.

Authors:  S J Steindel; D A Novis
Journal:  Arch Pathol Lab Med       Date:  1999-07       Impact factor: 5.534

9.  Evaluation of a soft-handling computerized pneumatic tube specimen delivery system. Effects on analytical results and turnaround time.

Authors:  A A Keshgegian; G E Bull
Journal:  Am J Clin Pathol       Date:  1992-04       Impact factor: 2.493

10.  Timeliness of automated routine laboratory tests: a College of American Pathologists Q-Probes study of 653 institutions.

Authors:  S J Steindel; B A Jones; P J Howanitz
Journal:  Clin Chim Acta       Date:  1996-07-15       Impact factor: 3.786

View more
  1 in total

1.  Urea-mediated dissociation alleviate the false-positive Treponema pallidum-specific antibodies detected by ELISA.

Authors:  Qiang Wang; Yan Lei; Xiaolan Lu; Guangrong Wang; Qin Du; Xiaolan Guo; Yan Xing; Guoyuan Zhang; Dongsheng Wang
Journal:  PLoS One       Date:  2019-03-05       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.