Literature DB >> 15533975

Fusion of computed tomography data and optical 3D images of the dentition for streak artefact correction in the simulation of orthognathic surgery.

E Nkenke1, S Zachow, M Benz, T Maier, K Veit, M Kramer, S Benz, G Häusler, F Wilhelm Neukam, M Lell.   

Abstract

OBJECTIVE: To determine the limits of accuracy of fusion of optical three-dimensional (3D) imaging and computed tomography (CT) with and without metal artefacts in an experimental setting and to show the application of this hybrid system in 3D orthognathic surgery simulation.
METHODS: Ten plaster casts of dental arches were subjected to a CT scan and optical 3D surface imaging. Subsequently, the first molars in the plaster casts were supplied with metal restorations, bilaterally, and new CT scans and optical surface images were assessed. The registration of the surface data of the two imaging modalities of the study models without and with metal restorations was carried out. The mean distance between the two data sets was calculated. From a patient a CT scan of the skull as well as optical 3D images of plaster casts of the dental arches were acquired. Again the two imaging modalities were registered and virtual orthognathic surgery simulation was carried out.
RESULTS: The mean distance between the corresponding data points of CT and optical 3D surface images was 0.1262+/-0.0301 mm and 0.2671+/-0.0580 mm, respectively, for the plaster casts without and with metal restorations. The differences between these data were statistically significant (P<0.0005). For the patient case a mean difference of 0.66+/-0.49 mm and 0.56+/-0.48 mm for mandible and maxilla, respectively, was calculated between CT and optical surface data.
CONCLUSION: The accuracy of the fusion of 3D CT surface data and optical 3D imaging is significantly reduced by metal artefacts. However, it seems appropriate for virtual orthognathic surgery simulation, as post-operative orthodontics are performed frequently.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15533975     DOI: 10.1259/dmfr/27071199

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  23 in total

1.  Superimposition of 3D cone-beam CT models of orthognathic surgery patients.

Authors:  L H S Cevidanes; L J Bailey; G R Tucker; M A Styner; A Mol; C L Phillips; W R Proffit; T Turvey
Journal:  Dentomaxillofac Radiol       Date:  2005-11       Impact factor: 2.419

2.  Image analysis and superimposition of 3-dimensional cone-beam computed tomography models.

Authors:  Lucia H S Cevidanes; Martin A Styner; William R Proffit
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-05       Impact factor: 2.650

3.  A paradigm shift in the diagnosis & management of dentofacial deformities.

Authors:  Ashraf F Ayoub; B Khambay
Journal:  Saudi Dent J       Date:  2012-07

4.  [Evaluation of individual ceramic implants made of Bioverit with CAD/CAM technology to reconstruct multidimensional craniofacial defects of the human skull].

Authors:  H Siebert; P Schleier; J Beinemann; W Fried; W Zenk; D Schumann
Journal:  Mund Kiefer Gesichtschir       Date:  2006-05

5.  [Method and accuracy of determining the jaw position of repositioning splint with the aid of digital technique].

Authors:  S B Fang; G J Yang; Y F Kang; Y C Sun; Q F Xie
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-21

6.  The effect of computed tomographic scanner parameters and 3-dimensional volume rendering techniques on the accuracy of linear, angular, and volumetric measurements of the mandible.

Authors:  Brian J Whyms; Houri K Vorperian; Lindell R Gentry; Eugene M Schimek; Edward T Bersu; Moo K Chung
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2013-05

7.  Three-dimensional analysis of changes of the malar-midfacial region after LeFort I osteotomy and maxillary advancement.

Authors:  Emeka Nkenke; Eleftherios Vairaktaris; Manuel Kramer; Andreas Schlegel; Alexandra Holst; Ursula Hirschfelder; Jörg Wiltfang; Friedrich Wilhelm Neukam; Marc Stamminger
Journal:  Oral Maxillofac Surg       Date:  2008-05

8.  Integration of digital dental casts in cone-beam computed tomography scans.

Authors:  Frits A Rangel; Thomas J J Maal; Stefaan J Bergé; Anne Marie Kuijpers-Jagtman
Journal:  ISRN Dent       Date:  2012-09-23

9.  Creation of 3D multi-body orthodontic models by using independent imaging sensors.

Authors:  Sandro Barone; Alessandro Paoli; Armando Viviano Razionale
Journal:  Sensors (Basel)       Date:  2013-02-05       Impact factor: 3.576

10.  Accuracy and reliability of a novel method for fusion of digital dental casts and Cone Beam Computed Tomography scans.

Authors:  Frits A Rangel; Thomas J J Maal; Ewald M Bronkhorst; K Hero Breuning; Jan G J H Schols; Stefaan J Bergé; Anne Marie Kuijpers-Jagtman
Journal:  PLoS One       Date:  2013-03-20       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.