Reduction of residual dipolar interaction in cartilage by spin-lock technique.

Sarma V S Akella1, Ravinder R Regatte, Andrew J Wheaton, Arijitt Borthakur, Ravinder Reddy.   

Abstract

The influence of radiofrequency (RF) spin-lock pulse on the laminar appearance of articular cartilage in MR images was investigated. Spin-lock MRI experiments were performed on bovine cartilage plugs on a 4.7 Tesla small-bore MRI scanner, and on human knee cartilage in vivo on a 1.5 Tesla clinical scanner. When the normal to the surface of cartilage was parallel to B0, a typical laminar appearance was exhibited in T2-weighted images of cartilage plugs, but was absent in T1rho-weighted images of the same plugs. At the "magic angle" orientation (when the normal to the surface of cartilage was 54.7 degrees with respect to B0), neither the T2 nor the T1rho images demonstrated laminae. At the same time, T1rho values were greater than T2 at both orientations throughout the cartilage. T1rho dispersion (i.e., the dependence of the relaxation rate on the spin-lock frequency omega1) was observed, which reached a steady-state value of close to 2 kHz in both parallel and magic-angle orientations. These results suggest that residual dipolar interaction from motionally-restricted water and relaxation processes, such as chemical exchange, contribute to T1rho dispersion in cartilage. Further, one can reduce the laminar appearance in human articular cartilage by applying spin-lock RF pulses, which may lead to a more accurate diagnosis of degenerative changes in cartilage. (c) 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15508163     DOI: 10.1002/mrm.20241

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  61 in total

1.  Association of MR relaxation and cartilage deformation in knee osteoarthritis.

Authors:  K Subburaj; R B Souza; C Stehling; B T Wyman; M-P Le Graverand-Gastineau; T M Link; X Li; S Majumdar
Journal:  J Orthop Res       Date:  2011-12-07       Impact factor: 3.494

2.  Orientational dependent sensitivities of T2 and T1ρ towards trypsin degradation and Gd-DTPA2- presence in bovine nasal cartilage.

Authors:  Nian Wang; Yang Xia
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

3.  MRI rotating frame relaxation measurements for articular cartilage assessment.

Authors:  Jutta Ellermann; Wen Ling; Mikko J Nissi; Elizabeth Arendt; Cathy S Carlson; Michael Garwood; Shalom Michaeli; Silvia Mangia
Journal:  Magn Reson Imaging       Date:  2013-08-30       Impact factor: 2.546

4.  Biexponential T relaxation mapping of human knee cartilage in vivo at 3 T.

Authors:  Azadeh Sharafi; Ding Xia; Gregory Chang; Ravinder R Regatte
Journal:  NMR Biomed       Date:  2017-06-20       Impact factor: 4.044

5.  Compensation for spin-lock artifacts using an off-resonance rotary echo in T1rhooff-weighted imaging.

Authors:  Walter R T Witschey; Arijitt Borthakur; Mark A Elliott; Eric Mellon; Sampreet Niyogi; Chenyang Wang; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

6.  Artifacts in T1 rho-weighted imaging: compensation for B(1) and B(0) field imperfections.

Authors:  Walter R T Witschey; Arijitt Borthakur; Mark A Elliott; Eric Mellon; Sampreet Niyogi; Daniel J Wallman; Chenyang Wang; Ravinder Reddy
Journal:  J Magn Reson       Date:  2007-01-26       Impact factor: 2.229

7.  Compressed sensing in quantitative determination of GAG concentration in cartilage by microscopic MRI.

Authors:  Nian Wang; Farid Badar; Yang Xia
Journal:  Magn Reson Med       Date:  2017-10-30       Impact factor: 4.668

Review 8.  Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage.

Authors:  Arijitt Borthakur; Eric Mellon; Sampreet Niyogi; Walter Witschey; J Bruce Kneeland; Ravinder Reddy
Journal:  NMR Biomed       Date:  2006-11       Impact factor: 4.044

Review 9.  T₁ρ MRI of human musculoskeletal system.

Authors:  Ligong Wang; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2014-06-17       Impact factor: 4.813

10.  Composite metric R2  - R (1/T2  - 1/T ) as a potential MR imaging biomarker associated with changes in pain after ACL reconstruction: A six-month follow-up.

Authors:  Colin Russell; Valentina Pedoia; Sharmila Majumdar
Journal:  J Orthop Res       Date:  2016-09-16       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.