Effects of left ventricular assist device support and outflow graft location upon aortic blood flow.

Kenneth N Litwak1, Steven C Koenig, Hiroyuki Tsukui, Shin'ichiro Kihara, Zhongjun Wu, George M Pantalos.   

Abstract

Although continuous flow (CFVAD) and pulsatile (PVAD) ventricular assist devices (VADs) are being clinically used, their effects upon aortic blood flow as a measure of overall blood distribution remain unclear. The objective of this study was to compare the effects of CFVAD and PVAD support for ascending (AscA) and descending (DA) aorta outflow cannulation upon mean aortic blood flow and waveform morphology. Six experiments were conducted in a normal, acute calf model, in which an inflow cannula was implanted in the left ventricle apex and outflow cannulae were anastomosed to both the AscA and DA. Flow probes were placed around the pulmonary artery, pump outflow, brachiocephalic trunk, and aorta proximal and distal to the DA outflow. For each acute experiment, calves received randomly selected levels of VAD support (0-100% of cardiac output) and pump failure (VAD off and outflow cannula unclamped) for each of four randomly selected test conditions: (1) PVAD and AscA, (2) PVAD and DA, (3) CFVAD and AscA, and (4) CFVAD and DA. Regardless of pump type or support level, proximal and distal aorta mean flows were lower (p < 0.05) for DA compared with the AscA. No differences in mean aortic flows between pump types at either outflow graft location were discerned. Differences in morphologic features of blood flow waveforms between PVAD and CFVAD were observed. During simulated pump failure, retrograde aortic blood flow in both the aortic arch and DA was observed. Partial ventricular suction was also observed during the greatest levels of CFVAD support and suggested pronounced effects upon both the right and left ventricle. Collectively, these findings imply that VAD outflow location may have an important role in patient response and recovery. Investigation of the long-term pathophysiologic responses to pump type and outflow location is ongoing.

Entities:  

Mesh:

Year:  2004        PMID: 15497381     DOI: 10.1097/01.mat.0000136505.27884.f8

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  7 in total

Review 1.  Imaging in patients after cardiac transplantation and in patients with ventricular assist devices.

Authors:  Bhanu Gupta; Dany Jacob; Randall Thompson
Journal:  J Nucl Cardiol       Date:  2015-04-02       Impact factor: 5.952

Review 2.  Management of aortic insufficiency in the continuous flow left ventricular assist device population.

Authors:  Jonathan Holtz; Jeffrey Teuteberg
Journal:  Curr Heart Fail Rep       Date:  2014-03

3.  Outcomes of midterm circulatory support by left ventricular assist device implantation with descending aortic anastomosis.

Authors:  Kan Nawata; Takashi Nishimura; Shunei Kyo; Motoyuki Hisagi; Osamu Kinoshita; Aya Saito; Noboru Motomura; Shinichi Takamoto; Minoru Ono
Journal:  J Artif Organs       Date:  2010-10-30       Impact factor: 1.731

4.  Thrombotic occlusion of the ascending aorta after Toyobo LVAD implantation with descending aortic perfusion in a post-Bentall patient.

Authors:  Kan Nawata; Takashi Nishimura; Shunei Kyo; Motoyuki Hisagi; Osamu Kinoshita; Aya Saito; Noboru Motomura; Shinichi Takamoto; Minoru Ono
Journal:  J Artif Organs       Date:  2010-11-06       Impact factor: 1.731

5.  The development of aortic insufficiency in left ventricular assist device-supported patients.

Authors:  Jennifer Cowger; Francis D Pagani; Jonathan W Haft; Matthew A Romano; Keith D Aaronson; Theodore J Kolias
Journal:  Circ Heart Fail       Date:  2010-08-25       Impact factor: 8.790

Review 6.  Miniaturization of mechanical circulatory support systems.

Authors:  Guruprasad A Giridharan; Thomas J Lee; Mickey Ising; Michael A Sobieski; Steven C Koenig; Laman A Gray; Mark S Slaughter
Journal:  Artif Organs       Date:  2012-08       Impact factor: 3.094

7.  Screening for Outflow Cannula Malfunction of Left Ventricular Assist Devices (LVADs) With the Use of Doppler Echocardiography: New LVAD-Specific Reference Values for Contemporary Devices.

Authors:  Jonathan Grinstein; Eric Kruse; Keith Collins; Gabriel Sayer; Savitri Fedson; Gene H Kim; Nitasha Sarswat; Sirtaz Adatya; Takeyoshi Ota; Valluvan Jeevanandam; Victor Mor-Avi; Nir Uriel; Roberto M Lang
Journal:  J Card Fail       Date:  2016-06-08       Impact factor: 5.712

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.