Outcomes of midterm circulatory support by left ventricular assist device implantation with descending aortic anastomosis.

Kan Nawata1, Takashi Nishimura, Shunei Kyo, Motoyuki Hisagi, Osamu Kinoshita, Aya Saito, Noboru Motomura, Shinichi Takamoto, Minoru Ono.   

Abstract

For some patients undergoing left ventricular assist device (LVAD) implantation, the perfusion tube is anastomosed to the descending aorta instead of the currently more prevalently used ascending aorta. Purpose of this study was to assess retrospectively the outcomes of LVAD patients with descending aortic anastomosis. Between March 2007 and March 2010, six patients underwent LVAD implantation with descending aortic anastomosis with Toyobo or Jarvik 2000 LVAD at our institute. Their average circulatory support time was 434 (range 82-751) days. Both types of LVAD afforded adequate circulatory support, and inotrope treatment and mechanical ventilation were discontinued relatively early. Echocardiograms of the three patients with Jarvik 2000 LVAD revealed antegrade flow in the ascending aorta during the intermittent low-speed period. Among them, one patient developed infarction in the right brain hemisphere because of thromboembolism, whereas another patient developed pneumonia in the left lung followed by a lethal systemic infection. One patient on Toyobo LVAD support reached heart transplantation without morbidity. Another patient implanted with Toyobo LVAD, whose left ventricular function was too poor to generate forward flow through aortic valve, developed thrombus in the ascending aorta. No embolic events were observed in the organs below the diaphragm. In conclusion, descending aortic anastomosis of the perfusion tube can be used for LVAD implantation for some patients, but considerable risks of morbidities, including thromboembolic events and/or infection, should be recognized.

Entities:  

Mesh:

Year:  2010        PMID: 21049276     DOI: 10.1007/s10047-010-0521-0

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  11 in total

1.  Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy.

Authors:  Richard N Pierson; Renee Howser; Terri Donaldson; Walter H Merrill; Rebecca J Dignan; Davis C Drinkwater; Karla G Christian; Javed Butler; Don Chomsky; John R Wilson; Rick Clark; Stacy F Davis
Journal:  Ann Thorac Surg       Date:  2002-03       Impact factor: 4.330

2.  Ventricular assist device support in patients with mechanical heart valves.

Authors:  M T Swartz; G A Lowdermilk; D A Moroney; L R McBride
Journal:  Ann Thorac Surg       Date:  1999-12       Impact factor: 4.330

3.  Infection after implantation of pulsatile mechanical circulatory support devices.

Authors:  William L Holman; James K Kirklin; David C Naftel; Robert L Kormos; Patricia Desvign-Nickens; Margarita T Camacho; Deborah D Ascheim
Journal:  J Thorac Cardiovasc Surg       Date:  2010-04-03       Impact factor: 5.209

4.  The effect of intermittent low speed mode upon aortic valve opening in calves supported with a Jarvik 2000 axial flow device.

Authors:  Egemen Tuzun; Igor D Gregoric; Jeff L Conger; Kenny Golden; Robert Jarvik; O H Frazier; Kamuran A Kadipasaoglu
Journal:  ASAIO J       Date:  2005 Mar-Apr       Impact factor: 2.872

5.  Femoral versus aortic cannulation for surgery of chronic ascending aortic aneurysm.

Authors:  Fitsum Lakew; Piotr Pasek; Michael Zacher; Anno Diegeler; Paul P Urbanski
Journal:  Ann Thorac Surg       Date:  2005-07       Impact factor: 4.330

6.  Effects of left ventricular assist device support and outflow graft location upon aortic blood flow.

Authors:  Kenneth N Litwak; Steven C Koenig; Hiroyuki Tsukui; Shin'ichiro Kihara; Zhongjun Wu; George M Pantalos
Journal:  ASAIO J       Date:  2004 Sep-Oct       Impact factor: 2.872

7.  Midterm experience with the Jarvik 2000 axial flow left ventricular assist device.

Authors:  Saleem Haj-Yahia; Emma J Birks; Paula Rogers; Christopher Bowles; Mandy Hipkins; Robert George; Mohammed Amrani; Mario Petrou; John Pepper; Gilles Dreyfus; Asghar Khaghani
Journal:  J Thorac Cardiovasc Surg       Date:  2007-07       Impact factor: 5.209

8.  In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices.

Authors:  Paul L DiGiorgi; David L Smith; Yoshifumi Naka; Mehmet C Oz
Journal:  J Heart Lung Transplant       Date:  2004-02       Impact factor: 10.247

Review 9.  Does the arterial cannulation site for circulatory arrest influence stroke risk?

Authors:  Lars G Svensson; Eugene H Blackstone; Jeevanantham Rajeswaran; Joseph F Sabik; Bruce W Lytle; Gonzalo Gonzalez-Stawinski; Poseidon Varvitsiotis; Michael K Banbury; Patrick M McCarthy; Gösta B Pettersson; Delos M Cosgrove
Journal:  Ann Thorac Surg       Date:  2004-10       Impact factor: 4.330

10.  Retention of left ventricular assist device outflow grafts after transplantation.

Authors:  William E Cohn; Vid Fikfak; Igor D Gregoric; O H Frazier
Journal:  J Heart Lung Transplant       Date:  2008-07-07       Impact factor: 10.247

View more
  7 in total

Review 1.  Journal of Artificial Organs 2010: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2011-03-16       Impact factor: 1.731

2.  Minimally invasive HeartWare LVAD implantation through single left thoracotomy.

Authors:  Aron-Frederik Popov; Prashant Nanasaheb Mohite; Anton Sabashnikov; Alexander Weymann; Nikhil Prakash Patil; Diana García Sáez; Andre Ruediger Simon
Journal:  J Artif Organs       Date:  2015-01-08       Impact factor: 1.731

3.  Comparison of intraplatelet reactive oxygen species, mitochondrial damage, and platelet apoptosis after implantation of three continuous flow left ventricular assist devices: HeartMate II, Jarvik 2000, and HeartWare.

Authors:  Nandan K Mondal; Erik N Sorensen; Erika D Feller; Si M Pham; Bartley P Griffith; Zhongjun J Wu
Journal:  ASAIO J       Date:  2015 May-Jun       Impact factor: 2.872

4.  Current trends in implantable left ventricular assist devices.

Authors:  Jens Garbade; Hartmuth B Bittner; Markus J Barten; Friedrich-Wilhelm Mohr
Journal:  Cardiol Res Pract       Date:  2011-05-09       Impact factor: 1.866

Review 5.  Minimally invasive versus conventional continuous-flow left ventricular assist device implantation for heart failure: a meta-analysis.

Authors:  Bufan Zhang; Shaohua Guo; Zean Fu; Zhigang Liu
Journal:  Heart Fail Rev       Date:  2021-04-03       Impact factor: 4.654

Review 6.  Minimally-invasive LVAD Implantation: State of the Art.

Authors:  Jasmin S Hanke; Sebastian V Rojas; Murat Avsar; Axel Haverich; Jan D Schmitto
Journal:  Curr Cardiol Rev       Date:  2015

7.  2019 EACTS Expert Consensus on long-term mechanical circulatory support.

Authors:  Evgenij V Potapov; Christiaan Antonides; Maria G Crespo-Leiro; Alain Combes; Gloria Färber; Margaret M Hannan; Marian Kukucka; Nicolaas de Jonge; Antonio Loforte; Lars H Lund; Paul Mohacsi; Michiel Morshuis; Ivan Netuka; Mustafa Özbaran; Federico Pappalardo; Anna Mara Scandroglio; Martin Schweiger; Steven Tsui; Daniel Zimpfer; Finn Gustafsson
Journal:  Eur J Cardiothorac Surg       Date:  2019-08-01       Impact factor: 4.191

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.