Literature DB >> 15480891

Biomechanical comparison of inside-outside screws, cables, and regular screws, using a sawbone model.

Yusuf Sukru Caglar1, Fuat Torun, Thomas Glenn Pait, William Hogue, Melih Bozkurt, Serdar Ozgen.   

Abstract

Our aim was to conduct a biomechanical comparison of the pull-out strengths of inside-outside (I/O) screws, cables, and bone screws to determine whether I/O screws provide greater pull-out resistance than cables or bone screws, and their effectiveness with the screw diameter. There is no remarkable biomechanical experimental study comparing the I/O technique with conventional spinal techniques. The diameter of the screw heads were also biomechanically tested to determine the optimal size that can be used. In this study, 45 blocks of 50x50x5 mm of "sawbone" (synthetic bone, model 1137, Pacific Research Laboratories, Vashon, WA, USA) were used as bone substitutes. Fifteen sets of 14-mm inside-outside Dynalok screws and nuts, 15 wire cables, and 15 bone screws were inserted into a separate sawbone block. An MTS Bionx materials testing machine was used to measure the load to failure of each implant. The mean values and standard deviations of each group were calculated and Student's t-test was used for comparison. The load to failure of the inside-outside screws was significantly greater than that of the cables (p<0.0000004) and the regular bone screws (p<0.000002). The results also revealed that increasing the diameter of the head of the screw also increases the resistance against the pull-out strengths. Thus, using a larger screw in occipitocervical stabilization provides safe and stable fixation of the occipital bone to the cervical spine. This study also proved that sawbone is a useful and reliable alternative to allogenic fresh cadaveric bone grafts or animal bones for certain biomechanical testing.

Mesh:

Substances:

Year:  2004        PMID: 15480891     DOI: 10.1007/s10143-004-0350-9

Source DB:  PubMed          Journal:  Neurosurg Rev        ISSN: 0344-5607            Impact factor:   3.042


  26 in total

1.  Attenuation of acoustic emission body waves in acrylic bone cement and synthetic bone using wavelet time-scale analysis.

Authors:  G Qi
Journal:  J Biomed Mater Res       Date:  2000-10

2.  Biomechanical comparison of ankle arthrodesis techniques: crossed screws vs. blade plate.

Authors:  S Nasson; C Shuff; D Palmer; J Owen; J Wayne; J Carr; R Adelaar; D May
Journal:  Foot Ankle Int       Date:  2001-07       Impact factor: 2.827

3.  Two modifications of the Weil osteotomy: analysis on sawbone models.

Authors:  Eyal A Melamed; Lew C Schon; Mark S Myerson; Brent G Parks
Journal:  Foot Ankle Int       Date:  2002-05       Impact factor: 2.827

4.  Proximal metatarsal osteotomies: a comparative geometric analysis conducted on sawbone models.

Authors:  Meir Nyska; Hans-Jörg Trnka; Brent G Parks; Mark S Myerson
Journal:  Foot Ankle Int       Date:  2002-10       Impact factor: 2.827

5.  Posterior occipitocervical fusion. A preliminary report of a new technique.

Authors:  D Grob; J Dvorak; M Panjabi; M Froehlich; J Hayek
Journal:  Spine (Phila Pa 1976)       Date:  1991-03       Impact factor: 3.468

6.  The suboccipital cavernous sinus.

Authors:  K I Arnautović; O al-Mefty; T G Pait; A F Krisht; M M Husain
Journal:  J Neurosurg       Date:  1997-02       Impact factor: 5.115

7.  Posterior cervical fusion in chidren.

Authors:  J M McWhorter; E Alexander; C H Davis; L Kelly
Journal:  J Neurosurg       Date:  1976-08       Impact factor: 5.115

8.  Occipitocervical arthrodesis. Indications, technic and results.

Authors:  S A Grantham; H M Dick; R C Thompson; F E Stinchfield
Journal:  Clin Orthop Relat Res       Date:  1969 Jul-Aug       Impact factor: 4.176

9.  The management of tumors of the upper cervical spine.

Authors:  E J Dunn; P P Anas
Journal:  Orthop Clin North Am       Date:  1978-10       Impact factor: 2.472

10.  Posterior fusions of the upper cervical spine: indications, techniques, and prognosis.

Authors:  H H Sherk; B Snyder
Journal:  Orthop Clin North Am       Date:  1978-10       Impact factor: 2.472

View more
  4 in total

1.  Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study.

Authors:  Jan Bredow; Carolin Meyer; Max Joseph Scheyerer; Florian Siedek; Lars Peter Müller; Peer Eysel; Gregor Stein
Journal:  Eur Spine J       Date:  2016-01-25       Impact factor: 3.134

2.  Occipitocervical Fusion Surgery: Review of Operative Techniques and Results.

Authors:  Sunil Kukreja; Sudheer Ambekar; Anthony H Sin; Anil Nanda
Journal:  J Neurol Surg B Skull Base       Date:  2015-04-27

3.  Modified Inside-outside Occipito-Cervical Plate System: Preliminary Results.

Authors:  Sukru Caglar; Erhan Turkoglu; Hayri Kertmen; Bora Gurer; Huseyin Bozkurt; Rafet Ozay; Sahin Hanalioglu; Efkan Colpan
Journal:  Asian J Neurosurg       Date:  2019 Jan-Mar

4.  Evaluation of an occipito-cervico fusion with a new implant design: a biomechanical study.

Authors:  Filippo Migliorini; Alice Baroncini; Yasser El Mansy; Valentin Quack; Andreas Prescher; Max Mischer; Johannes Greven; Markus Tingart; Jörg Eschweiler
Journal:  BMC Musculoskelet Disord       Date:  2021-03-06       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.