Literature DB >> 15477051

Incidence and characteristics of failures in obstetric neuraxial analgesia and anesthesia: a retrospective analysis of 19,259 deliveries.

P H Pan1, T D Bogard, M D Owen.   

Abstract

A retrospective analysis was performed on 19,259 deliveries that occurred in our institution from January 2000 to December 2002. Anesthesia records and quality assurance data sheets were reviewed for the characteristics and failure rates of neuraxial blocks performed for labor analgesia and anesthesia. The neuraxial labor analgesia rate was 75% and the overall failure rate was 12%. After adequate analgesia from initial placement, 6.8% of patients had subsequent inadequate analgesia during labor that required epidural catheter replacement. Ultimately 98.8% of all patients received adequate analgesia even though 1.5% of patients had multiple replacements. Six percent of epidural catheters had initial intravenous placement but 46% were made functional by simple manipulations without higher subsequent failure. Unintended dural puncture occurred in 1.2% of labor neuraxial analgesia. The incidences of overall failure, intravenous epidural catheter, wet tap, inadequate epidural analgesia and catheter replacement were lower in patients receiving combined spinal-epidural versus epidural analgesia. For cesarean section, 7.1% of pre-existing labor epidural catheters failed and 4.3% of patients required conversion to general anesthesia. Spinal anesthesia for cesarean section had a lower failure rate of 2.7%, with 1.2% of the patients requiring general anesthesia. The overall use of general anesthesia decreased from 8% to 4.3% over the three-year period. Furthermore, regional anesthesia was used in 93.5% of cesarean deliveries with no anesthetic-related mortalities. Future investigations should identify acceptable international standards, risk factors associated with failure and methods to reduce failure before cesarean section.

Entities:  

Mesh:

Year:  2004        PMID: 15477051     DOI: 10.1016/j.ijoa.2004.04.008

Source DB:  PubMed          Journal:  Int J Obstet Anesth        ISSN: 0959-289X            Impact factor:   2.603


  55 in total

Review 1.  Pharmacology of drugs formulated with DepoFoam: a sustained release drug delivery system for parenteral administration using multivesicular liposome technology.

Authors:  Martin S Angst; David R Drover
Journal:  Clin Pharmacokinet       Date:  2006       Impact factor: 6.447

2.  Why epidurals do not always work.

Authors:  Katherine Arendt; Scott Segal
Journal:  Rev Obstet Gynecol       Date:  2008

3.  Analgesia in Obstetrics.

Authors:  M Heesen; M Veeser
Journal:  Geburtshilfe Frauenheilkd       Date:  2012-07       Impact factor: 2.915

4.  Investigating a Needle-Based Epidural Procedure in Obstetric Anesthesia.

Authors:  Eva K Lee; Haozheng Tian; Jinha Lee; Xin Wie; John Neeld; K Doug Smith; Alan R Kaplan
Journal:  AMIA Annu Symp Proc       Date:  2018-12-05

5.  THE EFFECT OF COMBINING AXILLARY BRACHIAL PLEXUS BLOCK WITH INTERSCALENE OR SUPRACLAVICULAR BLOCK FOR UPPER LIMB SURGERIES USING NEUROSTIMULATION TECHNIQUE.

Authors:  H O Idehen; C A Imarengiaye
Journal:  J West Afr Coll Surg       Date:  2016 Apr-Jun

6.  The impact of body mass index on the risk of high spinal block in parturients undergoing cesarean delivery: a retrospective cohort study.

Authors:  Agnes M Lamon; Lisa M Einhorn; Mary Cooter; Ashraf S Habib
Journal:  J Anesth       Date:  2017-04-18       Impact factor: 2.078

7.  A pilot study to compare epidural identification and catheterization using a saline-filled syringe versus a continuous hydrostatic pressure system.

Authors:  Yasser M Samhan; Hossam H El-Sabae; Hanan F Khafagy; Mohamed A Maher
Journal:  J Anesth       Date:  2013-02-14       Impact factor: 2.078

8.  Lumbosacral plexus injury following vaginal delivery with epidural analgesia -A case report-.

Authors:  Seil Park; Sung Wook Park; Keon Sik Kim
Journal:  Korean J Anesthesiol       Date:  2013-02-15

9.  Anaesthesia for lower-segment caesarean section: Changing perspectives.

Authors:  Sean Brian Yeoh; Sng Ban Leong; Alex Sia Tiong Heng
Journal:  Indian J Anaesth       Date:  2010-09

10.  Raman Spectroscopy Differentiates Each Tissue from the Skin to the Spinal Cord: A Novel Method for Epidural Needle Placement?

Authors:  T Anthony Anderson; Jeon Woong Kang; Tatyana Gubin; Ramachandra R Dasari; Peter T C So
Journal:  Anesthesiology       Date:  2016-10       Impact factor: 7.892

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.