Literature DB >> 23408046

A pilot study to compare epidural identification and catheterization using a saline-filled syringe versus a continuous hydrostatic pressure system.

Yasser M Samhan1, Hossam H El-Sabae, Hanan F Khafagy, Mohamed A Maher.   

Abstract

We are introducing a new continuous hydrostatic pressure system for identification and catheterization of epidural space in adults. One hundred and eight patients scheduled for elective endoscopic urological procedures were enrolled in this prospective randomized study. They were assigned to perform loss of resistance epidural technique by either the conventional saline-filled syringe (group C) or the new pressure technique (group P). The latter depends on observing passage of free flow of pressurized normal saline (50 mmHg) connected to epidural needle during its advancement, and then the epidural catheter was inserted to "float" easily while saline was flowing. Ten ml of bupivacaine 0.5 % with 50 μg fentanyl were injected. Time to identify epidural space, number of attempts, ease of catheterization, sensory and motor block by Bromage scale after 20 min, quality of anesthesia and any side effects were recorded. Significant reduction was found in group P versus group C concerning time to identify epidural space [20 (6-40) vs. 60.5 (23-75) s with p = 0.001], number of attempts [1 (1-2) vs. 1 (1-4) with p = 0.02] and motor block [1 (0-3) vs. 2 (0-2) with p = 0.02], respectively. No significant difference in epidural catheterization, sensory block, quality of anesthesia and incidence of side effects. We concluded that this new technique is an easy way to identify epidural space using available tools in the operating room.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23408046     DOI: 10.1007/s00540-013-1567-y

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  10 in total

1.  Clinical results with the acoustic puncture assist device, a new acoustic device to identify the epidural space.

Authors:  Timo J Lechner; Maarten G van Wijk; Ad J Maas; Frank R van Dorsten; Ronald A Drost; Chris J Langenberg; Leo J Teunissen; Paul H Cornelissen; Jan van Niekerk
Journal:  Anesth Analg       Date:  2003-04       Impact factor: 5.108

2.  Epidrum(®): a new device to identify the epidural space with an epidural Tuohy needle.

Authors:  Atsushi Sawada; Natsumi Kii; Yusuke Yoshikawa; Michiaki Yamakage
Journal:  J Anesth       Date:  2011-11-13       Impact factor: 2.078

3.  A pilot study to compare the Episure Autodetect syringe with the glass syringe for identification of the epidural space in parturients.

Authors:  Ashraf S Habib; Ronald B George; Terrence K Allen; Adeyemi J Olufolabi
Journal:  Anesth Analg       Date:  2008-02       Impact factor: 5.108

4.  Identification of the epidural space using pressure measurement with the compuflo injection pump--a pilot study.

Authors:  Oscar Ghelber; Ralf E Gebhard; Sejal Vora; Carin A Hagberg; Peter Szmuk
Journal:  Reg Anesth Pain Med       Date:  2008 Jul-Aug       Impact factor: 6.288

5.  Efficacy of ultrasound imaging in obstetric epidural anesthesia.

Authors:  Thomas Grau; Rudiger Wolfgang Leipold; Renate Conradi; Eike Martin; Johann Motsch
Journal:  J Clin Anesth       Date:  2002-05       Impact factor: 9.452

6.  Incidence of epidural catheter replacement in parturients: a retrospective chart review.

Authors:  S Eappen; A Blinn; S Segal
Journal:  Int J Obstet Anesth       Date:  1998-10       Impact factor: 2.603

7.  Identification of the epidural space in children. The application of a micro-drip infusion set.

Authors:  M Yamashita; M Tsuji
Journal:  Anaesthesia       Date:  1991-10       Impact factor: 6.955

8.  The Episure syringe: a novel loss of resistance syringe for locating the epidural space.

Authors:  Edward T Riley; Brendan Carvalho
Journal:  Anesth Analg       Date:  2007-10       Impact factor: 5.108

9.  Incidence and characteristics of failures in obstetric neuraxial analgesia and anesthesia: a retrospective analysis of 19,259 deliveries.

Authors:  P H Pan; T D Bogard; M D Owen
Journal:  Int J Obstet Anesth       Date:  2004-10       Impact factor: 2.603

10.  Determination of epidural catheter placement using nerve stimulation in obstetric patients.

Authors:  B C Tsui; S Gupta; B Finucane
Journal:  Reg Anesth Pain Med       Date:  1999 Jan-Feb       Impact factor: 6.288

  10 in total
  2 in total

1.  A proposal of a simple epidural simulator for training novice anesthesiologists.

Authors:  Sung-Moon Jeong; Jae Moon Choi; Ji Hyun Kim; Hwanhee Yoo; Sukyung Lee; Hyungseok Seo; Sooyoung Kim; Sung-Hoon Kim
Journal:  J Anesth       Date:  2016-05-18       Impact factor: 2.078

Review 2.  Localization of epidural space: A review of available technologies.

Authors:  Hesham Elsharkawy; Abraham Sonny; Ki Jinn Chin
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2017 Jan-Mar
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.