Literature DB >> 15457430

The effect of stem design on end-of-stem pain in revision total knee arthroplasty.

Robert L Barrack1, Tom Stanley, Mark Burt, Shelby Hopkins.   

Abstract

A series of 143 revision total knee arthroplasties was evaluated using a Knee Society clinical score, radiographic assessment, and satisfaction questionnaire. Patients completed a pain drawing showing the location and severity of pain they experienced at 2 years follow-up. Two stem designs were used: a solid, fluted cobalt chrome stem (group I) and a slotted titanium stem (group II). End-of-stem pain was associated with solid cobalt chrome stems while a lower incidence of stem pain was associated with slotted titanium stems. Symptoms were intermittent and activity related in all but 2 cases, but none required component revision. The presence of end-of-stem pain did appear to be clinically significant because patients with this pain were more likely to be only somewhat satisfied or dissatisfied with their degree of pain relief compared to those without end-of-stem pain. Stem design does appear to impact the incidence of end-of-stem pain in revision total knee arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15457430     DOI: 10.1016/j.arth.2004.06.009

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  22 in total

Review 1.  Fixation of revision TKA: a review of the literature.

Authors:  J Beckmann; C Lüring; R Springorum; F X Köck; J Grifka; M Tingart
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-07       Impact factor: 4.342

2.  Stem length in revision total knee arthroplasty.

Authors:  Anay Rajendra Patel; Brian Barlow; Amar S Ranawat
Journal:  Curr Rev Musculoskelet Med       Date:  2015-12

3.  Modified hybrid stem fixation in revision TKA is durable at 2 to 10 years.

Authors:  Alexander P Sah; Sanjai Shukla; Craig J Della Valle; Aaron G Rosenberg; Wayne G Paprosky
Journal:  Clin Orthop Relat Res       Date:  2010-09-28       Impact factor: 4.176

4.  Results of press-fit stems in revision knee arthroplasties.

Authors:  Gavin C Wood; Douglas D R Naudie; Steven J MacDonald; Richard W McCalden; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

5.  Biomechanical analysis of the tibial tray design in TKA: comparison between modular and offset tibial trays.

Authors:  Ângela Chan; João Gamelas; João Folgado; Paulo R Fernandes
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-28       Impact factor: 4.342

6.  Joint line changes and outcomes in constrained versus unconstrained total knee arthroplasty for the type II valgus knee.

Authors:  Hee-Nee Pang; Seng-Jin Yeo; Hwei-Chi Chong; Pak-Lin Chin; Shi-Lu Chia; Ngai-Nung Lo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-01-16       Impact factor: 4.342

7.  [Knee revision arthroplasty : cementless, metaphyseal fixation with sleeves].

Authors:  H Graichen; M Strauch; W Scior; R Morgan-Jones
Journal:  Oper Orthop Traumatol       Date:  2015-01-28       Impact factor: 1.154

8.  A 30-mm cemented stem extension provides adequate fixation of the tibial component in revision knee arthroplasty.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

9.  Clinical results and failure mechanisms of a nonmodular constrained knee without stem extensions.

Authors:  Denis Nam; Ben-Paul N Umunna; Michael B Cross; Keith R Reinhardt; Shivi Duggal; Charles N Cornell
Journal:  HSS J       Date:  2012-05-12

10.  Evaluation of the rotational alignment of the tibial component in total knee arthroplasty: position prioritizing maximum coverage.

Authors:  Masashi Hirakawa; Masashi Miyazaki; Shinichi Ikeda; Yoshiki Matsumoto; Makoto Kondo; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-09-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.