Literature DB >> 15457411

A prospective, randomized, double-blind study of smooth versus rough stems using cement fixation: minimum 5-year follow-up.

Vijay J Rasquinha1, Chitranjan S Ranawat, Vipul Dua, Amar S Ranawat, Jose A Rodriguez.   

Abstract

This prospective randomized double-blind study aims to evaluate the effect of surface finish of the cemented femoral stem in primary total hip arthroplasty. Between January 1996 and May 1997, a single surgeon prospectively implanted 244 primary THAs (237 patients) using cemented femoral stems with modified third-generation cement technique in selected patients. Patients were randomized to receive the Ranawat-Burstein prosthesis (Biomet, Warsaw, IN) with 1 of 2 finishes (smooth-Ra 17 or rough-Ra 170). At a minimum 5-year follow-up, no statistical differences were found between the 2 groups. One patient with a smooth stem underwent revision of the femoral component at 2 years secondary to aseptic loosening. There was no other evidence of radiographic loosening or osteolysis. As an isolated variable, surface finish does not appear to significantly influence results at mean follow-up of 6.5 years.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15457411     DOI: 10.1016/j.arth.2004.06.005

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Fatigue debonding of the roughened stem-cement interface: effects of surface roughness and stem heating conditions.

Authors:  Leatha A Damron; Do-Gyoon Kim; Kenneth A Mann
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2006-07       Impact factor: 3.368

2.  Minimum 10-year survival of Kerboull cemented stems according to surface finish.

Authors:  Moussa Hamadouche; François Baqué; Nicolas Lefevre; Marcel Kerboull
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

3.  High failure rate of a modern, proximally roughened, cemented stem for total hip arthroplasty.

Authors:  A Grose; A González Della Valle; P Bullough; S Lyman; I Tomek; P Pellicci
Journal:  Int Orthop       Date:  2006-04-29       Impact factor: 3.075

4.  Random damage and characteristics of debris particles are two important and yet ignored factors in the mechanical integrity of the stem-cement interface of a total hip replacement: influence of the surface finish of the metal stem.

Authors:  Gang Qi; Steven F Wayne; Kenneth A Mann; Bin Zhang; Gladius Lewis
Journal:  J Mater Sci Mater Med       Date:  2009-11-28       Impact factor: 3.896

  4 in total