Literature DB >> 1538439

Impact of the new cuff design on reliability of the AS800 artificial urinary sphincter.

J K Light1, J C Reynolds.   

Abstract

The effect of 2 cuff design changes on the mechanical reliability of the current AS800 artificial urinary sphincter was assessed in 126 patients. The surface-treated cuff was introduced in 1983 and the narrow-back design was introduced in 1987. Mean followup for the surface-treated cuff was 40 months, while that for the narrow back was 27.2 months. The incidence of cuff leaks was 1.3%, while the revision rate for clinically significant pressure atrophy, in the absence of a bladder flap urethroplasty, was 2.3%. The overall revision rate for clinically significant pressure atrophy was 9%. No leaks involving the balloon or tubing occurred. The mechanical reliability of the current AS800 artificial urinary sphincter has improved significantly.

Entities:  

Mesh:

Year:  1992        PMID: 1538439     DOI: 10.1016/s0022-5347(17)37319-6

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  12 in total

1.  The artificial urinary sphincter is the treatment of choice for post-radical prostatectomy incontinence.

Authors:  Sender Herschorn
Journal:  Can Urol Assoc J       Date:  2008-10       Impact factor: 1.862

2.  Management of urinary incontinence after radical prostatectomy.

Authors:  Thomas R Jarvis; Jaspreet S Sandhu
Journal:  Curr Urol Rep       Date:  2014-07       Impact factor: 3.092

3.  Comparison of complication rates related to male urethral slings and artificial urinary sphincters for urinary incontinence: national multi-institutional analysis of ACS-NSQIP database.

Authors:  Amjad Alwaal; Catherine R Harris; Mohannad A Awad; Isabel E Allen; Benjamin N Breyer
Journal:  Int Urol Nephrol       Date:  2016-07-14       Impact factor: 2.370

4.  Use of the artificial urinary sphincter in men and women.

Authors:  B C Leibovich; D M Barrett
Journal:  World J Urol       Date:  1997       Impact factor: 4.226

5.  Montreal electronic artificial urinary sphincters: Our futuristic alternatives to the AMS800™.

Authors:  Xavier Biardeau; Sami Hached; Oleg Loutochin; Lysanne Campeau; Mohamad Sawan; Jacques Corcos
Journal:  Can Urol Assoc J       Date:  2017-10       Impact factor: 1.862

Review 6.  [Therapy of male urinary incontinence: artificial sphincter versus male slings].

Authors:  W Leicht; J Thüroff
Journal:  Urologe A       Date:  2012-03       Impact factor: 0.639

7.  The surgical learning curve for artificial urinary sphincter procedures compared to typical surgeon experience.

Authors:  Jaspreet S Sandhu; Alexandra C Maschino; Andrew J Vickers
Journal:  Eur Urol       Date:  2011-06-07       Impact factor: 20.096

8.  [Artificial sphincter for the treatment of incontinence].

Authors:  N Djakovic; J Huber; J Nyarangi-Dix; M Hohenfellner
Journal:  Urologe A       Date:  2010-04       Impact factor: 0.639

9.  Long-term device survival and quality of life outcomes following artificial urinary sphincter placement.

Authors:  Timothy C Boswell; Daniel S Elliott; Laureano J Rangel; Brian J Linder
Journal:  Transl Androl Urol       Date:  2020-02

Review 10.  Artificial urinary sphincters for male stress urinary incontinence: current perspectives.

Authors:  Billy H Cordon; Nirmish Singla; Ajay K Singla
Journal:  Med Devices (Auckl)       Date:  2016-07-04
View more