Literature DB >> 15373447

Development and evaluation of a reference measurement procedure for the determination of total 3,3',5-triiodothyronine in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry.

Susan S-C Tai1, David M Bunk, Edward White, Michael J Welch.   

Abstract

3,3',5-Triiodothyronine (T3) is an important diagnostic marker for thyroid function. A reference measurement procedure (RMP) for total T3 in serum involving isotope dilution coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The method uses solid-phase extraction with mixed-mode retention mechanisms of reversed phase and ion exchange prior to reversed-phase LC/MS/MS. In addition to a labeled T3 internal standard (T3-13C9), labeled thyroxine (T4-d5) is also added to serum samples in order to monitor the degradation of T4 to T3. The accuracy of the measurement was evaluated by a recovery study for added T3 and was supported by a comparison study with the other RMP. The recovery of the added T3 ranged from 98.9% to 99.4%. The results of this method and the other RMP agreed to within 1%. Samples of frozen serum pools were prepared and measured in three separate sets. Excellent reproducibility was obtained with within-set coefficients of variation (CVs) ranging from 0.8% to 1.6% and between-set CVs ranging from 1.9% to 2.6%. Excellent linearity was also obtained with correlation coefficients of all linear regression lines (measured intensity ratios vs mass ratios) ranging from 0.9995 to 0.9996. The detection limit at a signal-to-noise ratio of approximately 3 was 1 pg of T3. The T4 degradation during sample preparation was minimized to a small percentage (no more than 3% of the T3 values) by use of antioxidants (ascorbic acid, dithiothreitol, citric acid) and can be accounted for in the T3 measurement process. This well-characterized LC/MS/MS method for total serum T3, which demonstrates good accuracy and precision, low susceptibility to interferences, accountability of the conversion of T4 to T3, and comparability with the other RMP, qualifies as a reference measurement procedure and can be used to provide an accuracy base to which routine methods for T3 can be compared. Copyright 2004 American Chemical Society

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15373447     DOI: 10.1021/ac049516h

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  25 in total

1.  Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry.

Authors:  Dongli Wang; Heather M Stapleton
Journal:  Anal Bioanal Chem       Date:  2010-05-01       Impact factor: 4.142

2.  Simultaneous quantification of T4, T3, rT3, 3,5-T2 and 3,3'-T2 in larval zebrafish (Danio rerio) as a model to study exposure to polychlorinated biphenyls.

Authors:  Xiaopeng Chen; Kyla M Walter; Galen W Miller; Pamela J Lein; Birgit Puschner
Journal:  Biomed Chromatogr       Date:  2018-01-29       Impact factor: 1.902

Review 3.  Candidate-based proteomics in the search for biomarkers of cardiovascular disease.

Authors:  Leigh Anderson
Journal:  J Physiol       Date:  2004-12-20       Impact factor: 5.182

Review 4.  Thyroid hormone analogues and derivatives: Actions in fatty liver.

Authors:  Maria Coppola; Daniela Glinni; Maria Moreno; Federica Cioffi; Elena Silvestri; Fernando Goglia
Journal:  World J Hepatol       Date:  2014-03-27

5.  Detection and quantification of 3,5,3'-triiodothyronine and 3,3',5'-triiodothyronine by electrospray ionization tandem mass spectrometry.

Authors:  Yuntao Zhang; Abigail H Conrad; Gary W Conrad
Journal:  J Am Soc Mass Spectrom       Date:  2005-09-22       Impact factor: 3.109

6.  Development of Standard Reference Materials to support assessment of iodine status for nutritional and public health purposes.

Authors:  Stephen E Long; Brittany L Catron; Ashley Sp Boggs; Susan Sc Tai; Stephen A Wise
Journal:  Am J Clin Nutr       Date:  2016-08-17       Impact factor: 7.045

7.  The measurement of free thyroxine by isotope dilution tandem mass spectrometry.

Authors:  Steven J Soldin; Nadia Soukhova; Natasa Janicic; Jacqueline Jonklaas; Offie P Soldin
Journal:  Clin Chim Acta       Date:  2005-04-12       Impact factor: 3.786

8.  Correlation between y-type ions observed in ion trap and triple quadrupole mass spectrometers.

Authors:  Carly A Sherwood; Ashley Eastham; Lik Wee Lee; Jenni Risler; Olga Vitek; Daniel B Martin
Journal:  J Proteome Res       Date:  2009-09       Impact factor: 4.466

9.  MaRiMba: a software application for spectral library-based MRM transition list assembly.

Authors:  Carly A Sherwood; Ashley Eastham; Lik Wee Lee; Amelia Peterson; Jimmy K Eng; David Shteynberg; Luis Mendoza; Eric W Deutsch; Jenni Risler; Natalie Tasman; Ruedi Aebersold; Henry Lam; Daniel B Martin
Journal:  J Proteome Res       Date:  2009-10       Impact factor: 4.466

10.  Validation of a liquid chromatography-tandem mass spectrometry method to enable quantification of 3-iodothyronamine from serum.

Authors:  Andrea E DeBarber; Travis Geraci; Vincent P Colasurdo; Sarah A Hackenmueller; Thomas S Scanlan
Journal:  J Chromatogr A       Date:  2008-09-12       Impact factor: 4.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.