Literature DB >> 16018881

The measurement of free thyroxine by isotope dilution tandem mass spectrometry.

Steven J Soldin1, Nadia Soukhova, Natasa Janicic, Jacqueline Jonklaas, Offie P Soldin.   

Abstract

BACKGROUND: Most clinical chemistry laboratories measure free thyroxine (FT4) by an analogue (direct) method. Nevertheless, the validity of analogue FT4 immunoassays has been questioned and patient's results using this approach frequently do not fit in with the clinical presentation. Because of these problems we routinely send out all direct free T4's that are < 2.5th percentile and many that are > 97.5th percentile for measurement by equilibrium dialysis, the gold standard method. In approximately half of these cases, the FT4 by equilibrium dialysis was normal. We developed a rapid, reliable free T4 method employing isotope dilution tandem mass spectrometry and compared our results with both the analogue (direct) free T4 and equilibrium dialysis procedures.
METHODS: An API-4000 tandem mass spectrometer (Sciex, Toronto, Canada) equipped with TurboIonSpray and Agilent HPLC system was used employing isotope dilution with deuterium labeled internal standard (IS=l-thyroxine-d2). Serum was filtered through the Centrifree YM-30 ultrafiltration device by centrifugation, IS added to the ultrafiltrate, and 400 microL injected onto a C-18 column. After washing, the switch valve is activated and a methanol gradient allows for elution of both T4 and the IS into the LC/MS/MS system. Quantitation was by MRM analysis in the negative mode. Equilibrium dialysis was performed by the Nichols method and analogue free T4 results were obtained on the Dade Dimension RxL.
RESULTS: The within-day and between-day CV's were < 7.1% at all concentrations tested. The results correlated well with equilibrium dialysis (Eq Dial=0.971 MS+0.041, n=68, Syx=1.381, r=0.954). A poor correlation was found with the analogue (direct) free T4 method (IA=0.326 MS+6.27, n=154, Syx=1.96, r=0.459).
CONCLUSIONS: Samples can be processed in batches of 30. The free T4 tandem MS method has a rapid turn-around-time vs the equilibrium dialysis procedure, with a chromatographic run time of 8 min per sample.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16018881      PMCID: PMC3636976          DOI: 10.1016/j.cccn.2005.02.010

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  15 in total

1.  Interferences in immunoassay--still a threat.

Authors:  L J Kricka
Journal:  Clin Chem       Date:  2000-08       Impact factor: 8.327

Review 2.  Human anti-mouse antibodies.

Authors:  G G Klee
Journal:  Arch Pathol Lab Med       Date:  2000-06       Impact factor: 5.534

3.  Trimester-specific reference intervals for thyroxine and triiodothyronine in pregnancy in iodine-sufficient women using isotope dilution tandem mass spectrometry and immunoassays.

Authors:  O P Soldin; L Hilakivi-Clarke; E Weiderpass; S J Soldin
Journal:  Clin Chim Acta       Date:  2004-11       Impact factor: 3.786

4.  The war on heterophilic antibody interference.

Authors:  Johan Bjerner; Ole P Børmer; Kjell Nustad
Journal:  Clin Chem       Date:  2005-01       Impact factor: 8.327

5.  Incidence and specificity of interference in two-site immunoassays.

Authors:  L M Boscato; M C Stuart
Journal:  Clin Chem       Date:  1986-08       Impact factor: 8.327

6.  Trimester-specific changes in maternal thyroid hormone, thyrotropin, and thyroglobulin concentrations during gestation: trends and associations across trimesters in iodine sufficiency.

Authors:  O P Soldin; R E Tractenberg; J G Hollowell; J Jonklaas; N Janicic; S J Soldin
Journal:  Thyroid       Date:  2004-12       Impact factor: 6.568

7.  Validity of analog free thyroxin immunoassays.

Authors:  R Ekins
Journal:  Clin Chem       Date:  1987-12       Impact factor: 8.327

8.  Candidate reference method for total thyroxine in human serum: use of isotope-dilution liquid chromatography-mass spectrometry with electrospray ionization.

Authors:  Susan S-C Tai; Lorna T Sniegoski; Michael J Welch
Journal:  Clin Chem       Date:  2002       Impact factor: 8.327

9.  Temperature effects on free-thyroxine measurements: analytical and clinical consequences.

Authors:  G van der Sluijs Veer; I Vermes; H A Bonte; R K Hoorn
Journal:  Clin Chem       Date:  1992-07       Impact factor: 8.327

10.  Isotope dilution tandem mass spectrometric method for T4/T3.

Authors:  Nadia Soukhova; Offie P Soldin; Steven J Soldin
Journal:  Clin Chim Acta       Date:  2004-05       Impact factor: 3.786

View more
  31 in total

1.  Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry.

Authors:  Dongli Wang; Heather M Stapleton
Journal:  Anal Bioanal Chem       Date:  2010-05-01       Impact factor: 4.142

2.  Is measurement of TT3 by immunoassay reliable at low concentrations? A comparison of the Roche Cobas 6000 vs. LC-MSMS.

Authors:  Likhona Siphe Masika; Zhen Zhao; Steven John Soldin
Journal:  Clin Biochem       Date:  2016-02-12       Impact factor: 3.281

3.  Simultaneous quantification of T4, T3, rT3, 3,5-T2 and 3,3'-T2 in larval zebrafish (Danio rerio) as a model to study exposure to polychlorinated biphenyls.

Authors:  Xiaopeng Chen; Kyla M Walter; Galen W Miller; Pamela J Lein; Birgit Puschner
Journal:  Biomed Chromatogr       Date:  2018-01-29       Impact factor: 1.902

Review 4.  Thyroid function testing in pregnancy and thyroid disease: trimester-specific reference intervals.

Authors:  Offie P Soldin
Journal:  Ther Drug Monit       Date:  2006-02       Impact factor: 3.681

5.  Tandem mass spectrometry improves the accuracy of free thyroxine measurements during pregnancy.

Authors:  Natasa Kahric-Janicic; Steven J Soldin; Offie P Soldin; Threvia West; Jianghong Gu; Jacqueline Jonklaas
Journal:  Thyroid       Date:  2007-04       Impact factor: 6.568

6.  Total and free thyroxine and triiodothyronine: measurement discrepancies, particularly in inpatients.

Authors:  Jacqueline Jonklaas; Anpalakan Sathasivam; Hong Wang; Jianghong Gu; Kenneth D Burman; Steven J Soldin
Journal:  Clin Biochem       Date:  2014-06-14       Impact factor: 3.281

7.  Validation of a liquid chromatography-tandem mass spectrometry method to enable quantification of 3-iodothyronamine from serum.

Authors:  Andrea E DeBarber; Travis Geraci; Vincent P Colasurdo; Sarah A Hackenmueller; Thomas S Scanlan
Journal:  J Chromatogr A       Date:  2008-09-12       Impact factor: 4.759

8.  Agreement of immunoassay and tandem mass spectrometry in the analysis of cortisol and free t4: interpretation and implications for clinicians.

Authors:  Rochelle E Tractenberg; Jacqueline Jonklaas; Steven J Soldin
Journal:  Int J Anal Chem       Date:  2010-07-12       Impact factor: 1.885

Review 9.  Thyroid functional disease: an under-recognized cardiovascular risk factor in kidney disease patients.

Authors:  Connie M Rhee; Gregory A Brent; Csaba P Kovesdy; Offie P Soldin; Danh Nguyen; Matthew J Budoff; Steven M Brunelli; Kamyar Kalantar-Zadeh
Journal:  Nephrol Dial Transplant       Date:  2014-02-25       Impact factor: 5.992

10.  Pediatric reference intervals for thyroid hormone levels from birth to adulthood: a retrospective study.

Authors:  Klaus Kapelari; Christine Kirchlechner; Wolfgang Högler; Katharina Schweitzer; Irene Virgolini; Roy Moncayo
Journal:  BMC Endocr Disord       Date:  2008-11-27       Impact factor: 2.763

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.